18 August 2021 in IEEE Transactions on Pattern Analysis and Machine Intelligence
With the development of signal processing technology, the ubiquitous Wi-Fi devices open an unprecedented opportunity to solve the challenging human gesture recognition problem by learning motion representations from wireless signals. Wi-Fi-based gesture recognition systems, although yield good performance on specific data domains, are still practically difficult to be used without explicit adaptation efforts to new domains. Various pioneering approaches have been proposed to resolve this contradiction but extra training efforts are still necessary for either data collection or model re-training when new data domains appear. To advance cross-domain recognition and achieve fully zero-effort recognition, we propose Widar3.0, a Wi-Fi-based zero-effort cross-domain gesture recognition system. The key insight of Widar3.0 is to derive and extract domain-independent features of human gestures at the lower signal level, which represent unique kinetic characteristics of gestures and are irrespective of domains. On this basis, we develop a one-fits-all general model that requires only one-time training but can adapt to different data domains. Experiments on various domain factors (i.e. environments, locations, and orientations of persons) demonstrate the accuracy of 92.7% for in-domain recognition and 82.6%-92.4% for cross-domain recognition without model re-training, outperforming the state-of-the-art solutions.
23 April 2021 in IEEE Internet of Things Journal
Heart rate variability (HRV), which measures the fluctuation of heartbeat intervals, has been considered as an important indicator for general health evaluation. To alleviate the user burden and explore the usability for long-term health monitoring, noncontact methods for HRV monitoring have drawn tremendous attention. In this article, we present mmHRV, the first contact-free multiuser HRV monitoring system using commercial millimeter-wave (mmWave) radio. The design of mmHRV consists of two key components. First, we develop a calibration-free target detector to identify each user’s location. Second, a heartbeat signal extractor is devised, which can optimize the decomposition of the phase of the channel information modulated by the chest movement and, thus, estimate the heartbeat signal. The exact time of heartbeats is estimated by finding the peak location of the heartbeat signal while the interbeat intervals (IBIs) can be further derived for evaluating the HRV metrics of each target. We evaluate the system performance and the impact of different settings, including the distance between human and the device, user orientation, incidental angle, and blockage. Experimental results show that mmHRV can measure the HRV accurately with a median IBI estimation error of 28 ms (with respect to 96.16% accuracy). In addition, the root-mean-square error (RMSE) measured in the nonline-of-sight (NLOS) scenarios is 31.71 ms based on the experiments with 11 participants. The performance of the multiuser scenario is slightly degraded compared with the single-user case; however, the median error of the 3-user case is within 52 ms for all three tested locations.
7 August 2017 in IEEE Transactions on Mobile Computing
The proliferation of mobile computing has prompted WiFi-based indoor localization to be one of the most attractive and promising techniques for ubiquitous applications. A primary concern for these technologies to be fully practical is to combat harsh indoor environmental dynamics, especially for long-term deployment. Despite numerous research on WiFi fingerprint-based localization, the problem of radio map adaptation has not been sufficiently studied and remains open. In this work, we propose AcMu, an automatic and continuous radio map self-updating service for wireless indoor localization that exploits the static behaviors of mobile devices. By accurately pinpointing mobile devices with a novel trajectory matching algorithm, we employ them as mobile reference points to collect real-time RSS samples when they are static. With these fresh reference data, we adapt the complete radio map by learning an underlying relationship of RSS dependency between different locations, which is expected to be relatively constant over time. Extensive experiments for 20 days across six months demonstrate that AcMu effectively accommodates RSS variations over time and derives accurate prediction of fresh radio map with average errors of less than 5dB, outperforming existing approaches. Moreover, AcMu provides 2x improvement on localization accuracy by maintaining an up-to-date radio map.
22 June 2020 in IEEE Internet of Things Journal
The continuous development of 802.11ad technology provides new opportunities in wireless sensing. In this work, we propose ViMo, a calibration-free remote Vital sign Monitoring system that can detect stationary/non-stationary users and estimate the respiration rates (RRs) as well as heart rates (HRs) built upon a commercial 60GHz WiFi. The design of ViMo consists of two key components. First, we design an adaptive object detector that can identify static objects, stationary human subjects and human in motion without any calibration. Second, we devise a robust HR estimator, which eliminates the respiration signal from the phase of the channel impulse response (CIR) to remove the interference of the harmonics from breathing and adopts dynamic programming (DP) to resist the random measurement noise. The influence of different settings, including the distance between human and the device, user orientation and incidental angle, blockage material, body movement and conditions of multi-user separation are investigated by extensive experiments. Experimental results show that ViMo monitors user’s vital signs accurately, with a median error of 0.19 BPM and 0.92 BPM, respectively, for RR and HR estimation.
6 September 2019 in IEEE Transactions on Mobile Computing
We present the model, design, and implementation of SMARS, the first practical Sleep Monitoring system that exploits Ambient Radio Signals to recognize sleep stages and assess sleep quality. This will enable a future smart home that monitors daily sleep in a ubiquitous and contactless manner. The key enabler underlying SMARS is a statistical model that accounts for all reflecting and scattering multipaths, allowing highly accurate and instantaneous breathing estimation with best-ever performance achieved on commodity devices. On this basis, SMARS then recognizes different sleep stages, including wake, rapid eye movement (REM), and non-REM (NREM), which was previously only possible with dedicated hardware. We implement a real-time system on commercial WiFi chipsets and deploy it in 6 homes. Our results demonstrate that SMARS yields a median absolute error of 0.47 breaths per minute (BPM), and detects breathing robustly even when a person is 10 meters away from the link. SMARS achieves sleep staging accuracy of 88%, outperforming the prevalent unobtrusive commodity solutions using bed sensor or UWB radar. By achieving promising results with merely a single commodity RF link, we believe that SMARS will set the stage for a practical in-home sleep monitoring solution.