11 August 2016 in IEEE Transactions on Biomedical Engineering
Objective: We present a benchmarking protocol for quantitatively comparing emerging on-scalp magnetoencephalography (MEG) sensor technologies to their counterparts in state-of-the-art MEG systems. Methods: As a means of validation, we compare a high-critical-temperature superconducting quantum interference device (high T, SQUID) with the low-T, SQUIDs of an Elekta Neuromag TRIUX system in MEG recordings of auditory and somatosensory evoked fields (SEFs) on one human subject. Results: We measure the expected signal gain for the auditory-evoked fields (deeper sources) and notice some unfamiliar features in the on-scalp sensor-based recordings of SEFs (shallower sources). Conclusion: The experimental results serve as a proof of principle for the benchmarking protocol. This approach is straightforward, general to various on-scalp MEG sensors, and convenient to use on human subjects. The unexpected features in the SEFs suggest on-scalp MEG sensors may reveal information about neuromagnetic sources that is otherwise difficult to extract from state-of-the-art MEG recordings. Significance: As the first systematically established on-scalp MEG benchmarking protocol, magnetic sensor developers can employ this method to prove the utility of their technology in MEG recordings. Further exploration of the SEFs with on-scalp MEG sensors may reveal unique information about their sources.
1 January 2020 in Superconductor Science and Technology
Inductance is a key parameter when optimizing the performance of superconducting quantum interference device (SQUID) magnetometers made from the high temperature superconductor YBa2Cu3O7−x
(YBCO) because lower SQUID inductance L leads to lower flux noise, but also weaker coupling to the pickup loop. In order to optimize the SQUID design, we combine inductance simulations and measurements to extract the different inductance contributions, and measure the dependence of the transfer function V Φ and flux noise on L. A comparison between two samples shows that the kinetic inductance contribution varies strongly with film quality, hence making inductance measurements a crucial part of the SQUID characterization. Thanks to the improved estimation of the kinetic inductance contribution, previously found discrepancies between theoretical estimates and measured values of V Φ and could to a large extent be avoided. We then use the measurements and improved theoretical estimations to optimize the SQUID geometry and reach a noise level of = 44 fT/ for the best SQUID magnetometer with a 8.6 mm × 9.2 mm directly coupled pickup loop. Lastly, we demonstrate a method for reliable one-time sensor calibration that is constant in a temperature range of several kelvin despite the presence of temperature dependent coupling contributions, such as the kinetic inductance. The found variability of the kinetic inductance contribution has implications not only for the design of YBCO SQUID magnetometers, but for all narrow linewidth SQUID-based devices operated close to their critical temperature.
20 October 2017 in Superconductor Science and Technology
Superconducting quantum interference devices (SQUIDs) based on high critical-temperature superconducting nanowire junctions were designed, fabricated, and characterized in terms of their potential as magnetometers for magnetoencephalography (MEG). In these devices, the high kinetic inductance of junctions and the thin film thickness (50 nm) pose special challenges in optimizing the field coupling. The high kinetic inductance also brings difficulties in reaching a low SQUID noise. To explore the technique for achieving a high field sensitivity, single-layer devices with a directly connected pickup loop and flip-chip devices with an inductively coupled flux transformer using a two-level coupling approach were fabricated and tested. Two-level coupling is an approach designed for flip-chip nanowire-based SQUIDs, in which a washer type SQUID pickup loop is introduced as an intermediate coupling level between the SQUID loop and the flux transformer input coil. The inductances and effective areas of all these devices were simulated. We found that at T = 77 K, flip-chip devices with the two-level coupling approach (coupling coefficient of 0.37) provided the best effective area of 0.46 mm 2 among all the tested devices. With a flux noise level of 55 0 , the field sensitivity level was 240 fT . This sensitivity is not yet adequate for MEG applications but it is the best level ever reached for nanowire-based high- T c SQUID magnetometers.
1 September 2014 in Ceramics International
18 April 2017 in Superconductor Science and Technology
Magnetoencephalography (MEG) systems based on a dense array of high critical temperature (high- T c ) superconducting quantum interference devices (SQUIDs) can theoretically outperform a state-of-the-art MEG system. On the way towards building such a multichannel system, we evaluate feedback methods suitable for use in dense high- T c SQUID arrays where the sensors are in very close proximity to the head (on-scalp MEG). We test on-chip superconducting coils and direct injection of the feedback current into the SQUID loop as alternatives to the wire-wound copper coils commonly used in single-channel high- T c SQUID-based MEG systems. For the evaluation, we have performed coupling, noise, and crosstalk measurements. We conclude that direct injection is the optimal solution for dense on-scalp MEG as it gives crosstalk below 0.5% even between SQUIDs whose pickup loops are within 0.8 mm of one another. Further, this solution provides sufficient flux coupling without adding additional noise. Finally, it does not compromise the standoff distance, which is important for on-scalp MEG.