Miao Peng

Miao Peng

Auto-generated profile, based on publicly available information

Miao Peng

Materials Genome Institute Shanghai University Shanghai China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 May 2023 in Environmental Science & Technology
Verified
Journal Article
Open access
Junjie ZhangJunjie Zhang
Junjie Zhang
MPMiao Peng
Miao Peng
ELEnkui Lian
Enkui Lian
LXLu Xia
Lu Xia
Alexandros AsimakopoulosAlexandros Asimakopoulos
Alexandros Asimakopoulos
LWLei Wang
Lei Wang
Micro/nanoplastics have emerged as global contaminants of serious concern to human and ecosystem health. However, identification and visualization of microplastics and particularly nanoplastics have remained elusive due to the lack of feasible and reliable analytical approaches, particularly for trace nanoplastics. Here, an efficient surface-enhanced Raman spectroscopy (SERS)-active substrate with triangular cavity arrays is reported. The fabricated substrate exhibited high SERS performance for standard polystyrene (PS) nanoplastic detection with size down to 50 nm and a detection limit of 0.001% (1.5 × 1011 particles/mL). Poly(ethylene terephthalate) (PET) nanoplastics collected from commercially bottled drinking water were detected with an average mean size of ∼88.2 nm. Furthermore, the concentration of the collected sample was estimated to be about 108 particles/mL by nanoparticle tracking analysis (NTA), and the annual nanoplastic consumption of human beings through bottled drinking water was also estimated to be about 1014 particles, assuming water consumption of 2 L/day for adults. The facile and highly sensitive SERS substrate provides more possibilities for detecting trace nanoplastics in an aquatic environment with high sensitivity and reliability.

1 August 2019 in Journal of Alloys and Compounds
Verified
Journal Article
Closed access
LHLixian Huang
Lixian Huang
BHBin Han
Bin Han
XHXihe Huang
Xihe Huang
SLShujie Liang
Shujie Liang
ZDZiqi Deng
Ziqi Deng
HDHong Deng
Hong Deng

1 July 2018 in Journal of Alloys and Compounds
Verified
Journal Article
Closed access
SLShujie Liang
Shujie Liang
BHBin Han
Bin Han
XLXueming Liu
Xueming Liu
WCWeiyi Chen
Weiyi Chen
MPMiao Peng
Miao Peng
ZLZhang Lin
Zhang Lin

15 September 2023 in Environmental Pollution
Verified
Journal Article
Closed access
MPMiao Peng
Miao Peng
MVMaaike Vercauteren
Maaike Vercauteren
CGCharlotte Grootaert
Charlotte Grootaert
Andreja RajkovicAndreja Rajkovic
Andreja Rajkovic
NBNico Boon
Nico Boon
JAJana Asselman
Jana Asselman

1 July 2019 in Journal of Hazardous Materials
Verified
Journal Article
Closed access
YSYao Song
Yao Song
JLJing Li
Jing Li
MPMiao Peng
Miao Peng
ZDZiqi Deng
Ziqi Deng
JYJianjun Yang
Jianjun Yang
ZLZhang Lin
Zhang Lin

15 November 2018 in Environmental Science: Nano
Verified
Journal Article
Closed access
PDF file
MPMiao Peng
Miao Peng
GGGuijian Guan
Guijian Guan
HDHong Deng
Hong Deng
BHBin Han
Bin Han
CTChen Tian
Chen Tian
ZLZhang Lin
Zhang Lin
Considering p-arsanilic acid (p-ASA) as an organoarsenic pollutant, monitoring concentration of p-ASA is significant to maintain environmental security. Photoelectrochemical (PEC) detection is promisingly applied in environmental monitoring for its lower cost and simpler operation, compared to traditional techniques. However, general electrode materials of PEC sensors need to be modified with biological probes due to lack of specific binding sites to analytes, which may lead to complicated sensor fabrication and bio-recognizers inactivation during storage. Herein, a porphyrinic metal–organic framework/reduced graphene oxide (PCN-224/rGO) nanocomposite with simultaneously excellent photoelectric activity and strong binding characteristics was prepared and used to fabricate a PEC sensor for p-ASA detection avoiding the modification of bio-recognizers. Benefiting from the high conductivity of rGO, the separation efficiency of charge carriers was improved in PCN-224/rGO and thereby photocurrent gained an amplification of about 12 times. The PCN-224/rGO nanocomposite had strong affinity to p-ASA via Zr–O–As coordination and π–π stacking. Significantly, the binding of p-ASA could adjust the band position of PCN-224/rGO and facilitate oxygen reduction by releasing more photogenerated electrons, achieving photocurrent enhancement. The developed PEC sensor had a wide detection range, from 10 ng L−1 to 10 mg L−1, with a detection limit of 5.47 ng L−1. Furthermore, the sensor was successfully applied to monitor p-ASA in simulated natural water and swine manure lixivium. This study paved the way for the design of more efficient PEC sensors for environmental monitoring.