A 24 year old male arrived to our hospital after a motor cycle crash with evidence of a traumatic brain injury and in hemorrhagic shock not responsive to volume administration. Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) was performed in a timely fashion using a new, low profile, wire free device. This lead to rapid reversal of hypotension while his bleeding source was sought and controlled. Recently, REBOA has emerged as an adjunct in the hypotensive trauma patient with noncompressible torso hemorrhage. As first described, this procedure makes use of commonly available vascular surgery and endovascular products requiring large introducer sheaths (12–14 French) and long guidewires. Concerns regarding this technique center around the safety and feasibility of using such equipment in the emergency setting outside an angiography suite. This has likely limited widespread adoption of this technique. To address these concerns, newer products designed to be placed through a smaller sheath (7 French) and without the use of guidewires have been developed. Here we report on our first clinical use of such a device that we believe represents a significant advance in the care of the trauma patient.
Background: Surveillance of ventilator-associated events (VAEs) as defined by the National Healthcare Safety Network (NHSN) is performed at many US trauma centers and considered a measure of healthcare quality. The surveillance algorithm relies in part on increases in positive end-expiratory pressure (PEEP) to identify VAEs. The purpose of this cohort study was to evaluate the effect of initiating mechanically ventilated trauma patients at marginally higher PEEP on incidence of VAEs. Methods: Analysis of level-1 trauma center patients mechanically ventilated 2+ days from 2017 to 2018 was performed after an institutional ventilation protocol increased initial PEEP setting from 5 (2017) to 6 (2018)cm H2O. Incidence of VAEs per 1000 vent days was compared between PEEP groups. Logistic regression modelling was performed to evaluate the impact of the PEEP setting change adjusted to account for age, ventilator days, injury mechanism and injury severity. Results: 519 patients met study criteria (274 PEEP 5 and 245 PEEP 6). Rates of VAEs were significantly reduced among patients with initial PEEP 5 versus 6 (14.61 per 1000 vent days vs. 7.13 per 1000 vent days; p=0.039). Logistic regression demonstrated that initial PEEP 6 was associated with 62% reduction in VAEs. Conclusions: Our data suggest that an incrementally increased baseline PEEP setting was associated with a significantly decreased incidence of VAEs among trauma patients. This minor change in practice may have a major impact on a trauma center’s quality metrics. Level of evidence: IV.