13 September 2004 in Rapid Communications in Mass Spectrometry
29 May 2019 in Analytical Chemistry
Improvements in the performance and availability of commercial instrumentation have made ion mobility – mass spectrometry (IM-MS) an increasingly popular approach for the structural analysis of ionic species as well as for separation of complex mixtures. Here, a new research instrument is presented which enables complex experiments, extending the current scope of IM technology. The instrument is based on a Waters SYNAPT G2-Si IM-MS platform, with the IM separation region modified to accept a cyclic ion mobility (cIM) device. The cIM region consists of a 98 cm path length, closed-loop travelling wave (TW)-enabled IM separator positioned orthogonally to the main ion optical axis. A key part of this geometry and its flexibility is the interface between the ion optical axis and the cIM, where a planar array of electrodes provides control over the TW direction and subsequent ion motion. On either side of the array, there are ion guides used for injection, ejection, storage and activation of ions. In addition to single and multi-pass separations around the cIM, providing selectable mobility resolution, the instrument design and control software enable a range of ‘multi-function’ experiments such as: mobility selection, activation, storage, IMSn and importantly, custom combinations of these functions. Here the design and performance of the cIM-MS instrument is highlighted, with mobility resolving power around 750 demonstrated for 100 passes around the cIM device using an inverse sequence peptide pair. The multi-function capabilities are demonstrated through analysis of three isomeric pentasaccharide species and the small protein ubiquitin.
11 April 2019 in Journal of the American Society for Mass Spectrometry
There is increasing biopharmaceutical interest in oligosaccharides and glycosylation. A key requirement for these sample types is the ability to characterize the chain length, branching, type of mo...
26 April 2018 in Nature Protocols
13 January 2011 in Journal of Molecular Biology
22 May 2019 in Analytical Chemistry
Ion mobility mass spectrometry (IM-MS) allows separation of native protein ions into “conformational families”. Increasing the IM resolving power should allow finer structural information to be obtained and can be achieved by increasing the length of the IM separator. This, however, increases the time that protein ions spend in the gas phase and previous experi-ments have shown that the initial conformations of small proteins can be lost within tens of milliseconds. Here, we report on investigations of protein ion stability using a multi-pass travelling wave (TW) cyclic IM (cIM) device. Using this device, min-imal structural changes were observed for Cytochrome C after hundreds of milliseconds, while no changes were observed for a larger multimeric complex (Concanavalin A). The geometry of the instrument (Q-cIM-ToF) also enables complex tandem IM experiments to be performed which were used to obtain more detailed collision induced unfolding pathways for Cyto-chrome C. The instrument geometry provides unique capabilities with the potential to expand the field of protein analysis via IM-MS.