Vivek Teja Tanjavooru

Vivek Teja Tanjavooru

Auto-generated profile, based on publicly available information

Vivek Teja Tanjavooru

Center for Combined Smart Energy Systems (CoSES), Technical University of Munich, Garching, Germany

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 June 2025 in Energy Storage
Verified
Journal Article
Open access
VTVivek Teja Tanjavooru
Vivek Teja Tanjavooru
MGMelina Graner
Melina Graner
PPPrashant Pant
Prashant Pant
THThomas Hamacher
Thomas Hamacher
HHHolger Hesse
Holger Hesse
This paper proposes an optimal control strategy for SOC balancing and introduces a framework for analyzing the spatial temperature distribution in a multi‐pack battery energy storage system (BESS) composed of multiple battery modules. While various control techniques exist to distribute power among parallel‐connected battery systems, their influence on the spatial temperature distribution within their modules is often neglected, despite temperature being a critical factor accelerating battery health degradation. To bridge this research gap, this framework integrates a 1D thermal simulation and state‐of‐health (SoH) estimation with power split control strategies. To showcase the application of this framework, a comparative study of two power‐sharing methods is conducted: (i) Model Predictive Control (MPC) based State of Charge (SoC) balancing, and (ii) Rule‐Based Control (RBC) strategies, highlighting their impact on temperature distribution and battery aging. Results show that MPC maintains a more uniform temperature profile, limiting peak temperatures to 300 K and minimizing SoH degradation, whereas RBC results in higher peak temperatures (314 K) and accelerated aging. In summary, this framework primarily intends to: (i) Enable researchers to further develop health‐aware power‐sharing strategies for BESS. (ii) Equip BESS operators with detailed spatial temperature insights to optimize power management and cooling systems.

1 May 2026 in IEEE Access
Verified
Journal Article
Open access
VTVivek Teja Tanjavooru
Vivek Teja Tanjavooru
PPPrashant Pant
Prashant Pant
MCMartin Cornejo
Martin Cornejo
THThomas Hamacher
Thomas Hamacher
Holger HesseHolger Hesse
Holger Hesse
Grid-connected multi-string battery energy storage systems (BESS) operating under sustained high-power conditions face heat accumulation, power derating, and cooling-related efficiency losses, leading to trade-offs among thermal management, efficiency, and system availability. To manage these competing objectives, this work proposes a mixed-integer nonlinear programming (MINLP)-based multi-objective optimization (MOO) framework for optimal power allocation across parallel strings under air cooling. The optimization incorporates an equivalent circuit model (ECM) with SOC-, temperature-, and C-rate dependent internal resistance, temperature-driven derating, and an experimentally derived inverter loss model. High-fidelity control is achieved by co-simulating the optimizer with an electro-thermal BESS simulation that captures spatial thermal dynamics of the battery pack. The simulation provides online state of charge (SOC) and temperature feedback and is validated against industry-measured battery pack temperatures, revealing core temperatures up to 4.5 ◦C higher than those predicted by conventional 0D average thermal models calibrated to pack surface measurements. Simulation results show that the baseline MINLP controller with evenly weighted objectives achieves approximately 3% higher round-trip efficiency (RTE) and system availability compared to the industrial benchmark droop control while minimizing thermal derating. Linearized optimal control without thermal optimization results in higher maximum string temperatures up to 40 ◦C and 4% higher derating losses. A Pareto-based objective prioritization improves energy performance by up to 5% while keeping temperatures below the 35 ◦C derating threshold. System scalability analysis shows that operating an optimal subset of strings outperforms conventional full-string operation, achieving 5.5% higher RTE with comparable availability and thermal performance. The framework is released open-source for adaptation to custom BESS applications.

26 October 2026 in Applied Energy
Verified
Journal Article
Open access
SYSheng Yin
Sheng Yin
VTVivek Teja Tanjavooru
Vivek Teja Tanjavooru
CGChristoph Goebel
Christoph Goebel
Holger HesseHolger Hesse
Holger Hesse

9 January 2025
Verified
Preprint
Open access
VTVivek Teja Tanjavooru
Vivek Teja Tanjavooru
MGMelina Graner
Melina Graner
PPPrashant Pant
Prashant Pant
THThomas Hamacher
Thomas Hamacher
HHHolger Hesse
Holger Hesse
The achievement of optimal lifetime and efficiency in stationary battery energy storage systems (BESS) is crucial and may require custom-made operational strategies for each grid application. This work focuses on addressing one of the key operational challenges: power distribution among the sub-units of a BESS, which leads to uneven aging and affects the overall usable capacity of a multi-pack battery system. While adjusting power setpoints of these sub-units can improve efficiency and aging performance, it can inherently introduce challenges of state of charge (SOC) imbalance within the system. This imbalance, coupled with temperature inhomogeneities in the battery packs, significantly affect the aging rate and further exacerbate system imbalances. To mitigate imbalances, a model predictive control (MPC)-based optimizer for SOC balancing is developed and evaluated against conventional and literature-derived rule-based control (RBC) strategies. Mixed-integer linear programming (MILP) is incorporated into the MPC optimizer to account for non-linear inverter losses during operation. A 1D thermal simulation, developed in this study, is used to analyze the temperature imbalances caused by these control strategies. The simulation estimates the spatial temperature distribution within each pack at the end of the operation, considering internal dissipative losses in the battery modules under fixed boundary conditions for passive air cooling. The comparative case study conducted in this work focuses on key performance metrics such as availability index (AI), fulfilment factor (FF), inverter and battery efficiencies, and state of health (SOH). These metrics are computed by coupling the power split control strategies with 1D thermal and aging estimation models through an equivalent circuit model (ECM). It suggests that due to the delayed balance of the SOC and non-uniform power distribution in RBC strategies, the availability and energy throughput of the system is lower than the desired 100% achieved using MPC. In addition, higher battery pack temperatures of up to 314 K in one of the RBC strategies were estimated, while MPC control induced a maximum temperature of up to 300 K thereby also achieving more balanced temperatures across packs. With the help of the SOC and temperature profiles during their operation, these control strategies are compared for their aging. MPC control strategy exhibited the lowest drop in state of health due to maintaining lower temperatures and mean SOC levels.