7 March 2022 in Frontiers in Built Environment
Workplace facilities are organizational capital assets, which entail high risks of fire occurrences. The fire risks increase based on occupants’ behaviors, lack of awareness and poor workspaces safety management. Thus, fire safety risk assessment is vital to raise awareness about workplace fire-safety culture, and to train employees on effective fire response requirements and methods. The literature lacks studies focusing on managing fire safety at the workplace, and limiting occupants dispossessed behaviors. This research presents a case study, which demonstrates the utilization of risk assessment for fire safety prevention in a workplace facility. Relevant literature is synthesized for identifying causes of fire, various propagation hazards, control measures to develop a risk assessment tool based on fire codes. The codes were analyzed by describing the requirements for fire safety precautionary measures, followed by an exemplary assessment. This research aims to provide professional practice and knowledge on the fire risk assessment methodology, serving safety professionals, and facilities managers. It serves to raise awareness on the causes of fire, consequences of fire events, and mitigation strategies in workplace facilities, for the purpose of protecting users’ lives and business properties against fires.
1 April 2022 in Journal of Building Engineering
1 July 2021 in International Journal of Emergency Services
Purpose: This research presents the applicable international fire code requirements for educational facilities, in a comprehensive manner, and the findings of a case study to assess the level of compliance with these requirements.Design/methodology/approach: A review of literature, fire codes and standards was conducted to identify the various sources of fire hazards in educational facilities and the required prevention measures. Accordingly, a code-compliance worksheet for assessing the fire prevention measures was developed. The worksheet included 34 prevention measures. It was implemented in a pharmacy college building, as a case study, to assess the compliance level with the code requirements. Recommendations were developed to improve the level of fire prevention in the case study facility.Findings: The implemented worksheet facilitated identifying all the shortcomings in the prevention measures, in a methodological manner. These shortcomings included exceeded travel distance, absence of assembly point, inactive record keeping of fire inspection and maintenance works, deterioration of some extension cords and switches, alteration of some emergency doors, storage of combustibles in some electrical rooms and obstructions of the fire apparatus access road.Practical implications: The research provides an assessment tool for fire prevention in educational facilities, which can be used by professionals for a code-compliant inspection. The findings of the case study as an example serve to expand the inspectors' observational significance while reducing subjectivity.Originality/value: This research contributes to the educational facilities' context of health and safety domain in the literature. The research classifies the required fire prevention measures for an educational facility, according to the international applicable codes and standards. The case study demonstrates an applicable methodology for assessing the fire prevention measures and requirements.
10 December 2020 in Archnet-IJAR: International Journal of Architectural Research
Purpose: This paper presents a systematic conduct of post-occupancy evaluation (POE) for polyclinic facilities at public hospitals. Design/methodology/approach: This is a mixed design research, where a review of literature was utilized, to qualitatively synthesize POE research on healthcare facilities. Three polyclinic facilities at Saudi Arabia were then assessed. The assessment was systematically conducted by the utilization of surveys and relative importance indices to solicit the experts’ and users' perspectives. The research included the conduct of physical measurements and walkthroughs inspections. Lastly, focus group meetings were conducted to generate recommendations that would improve the built environment conditions of polyclinic facilities. Findings: The research identified unsatisfactory zoning, indoor air quality and concerns related to installations of different systems. Performance elements and subsequent indicators were identified and evaluated for their significance. The knowledge of these, enables the systematic conduct of POE, by exemplary case studies, for the managers and decision-makers of polyclinic facilities. Originality/value: This research presents a comprehensive approach for the systematic conduct of POE at polyclinic facilities. The research enriches the literature and fulfils a contextual gap. The recommendations serve to enhance feedforward, the design and management of healthcare facilities.
8 December 2020 in Property Management
Purpose: This paper provides an exemplary systematic conduct of post‐occupancy evaluation (POE) on higher education facilities in Saudi Arabia.Design/methodology/approach: The research study utilized several qualitative and quantitative POE techniques which were systematically comprising (1) scoping and reviewing the facilities-related documents, (2) identification of performance indicators through the review of literature, (3) development and collection of questionnaire survey responses from stakeholders, (4) collection of physical measurements and (5) assessing the facilities by walk-throughs. Then, the data were analyzed and the findings were reported to representative samples of users through focus group meetings. Then, recommendations were drawn for improving the occupational conditions of the case study facilities.Findings: The synthesis of literature led to three main categories of performance elements that are relevant for higher education facilities. These include technical, functional and behavioral elements, in which each of the elements has specific performance indicators, 97 in total. The research study exemplifies a systematic conduct of POE. The stakeholders' perspectives on the performance elements through surveys, measurements and walk-throughs were collected. The assessment led to recommendations toward satisfactory and quality occupation of the case study facilities.Originality/value: This research aims to standardize POE by introducing its methods as a tool for evaluating higher education facilities and by elaborating the most prominent performance indicators for ensuring higher education core functions, namely, teaching, research and community collaboration.
28 July 2020 in Property Management
Purpose: The purpose of this paper is to holistically identify and assess the factors affecting the workplace relocation process during its various phases, namely: pre-relocation, relocation and post-relocation. The factors assessment evaluates the perspectives and level of agreement between facilities and real estate management professionals.Design/methodology/approach: Literature review was conducted to identify the factors affecting the workplace relocation process. In total, 34 factors were identified, which formed the basis of a questionnaire survey to assess their importance. Responses to the questionnaire survey were obtained through face-to-face interviews with two groups of professionals in the Eastern Province of Saudi Arabia, 32 facilities managers (FM) and 32 real estate managers (REM). The questionnaire utilized a 5-point Likert scale of importance.Findings: The research delivers rankings of the identified factors for prioritization. Where a moderate (to high) level of agreement between FM and REM professionals was remarked. Significant factors include: “availability of workplace health and safety plan”, “analysis of business needs for relocation”, “cost control and management of the relocation process”, “availability of maintenance plans” and “selection of fit-out contractor”.Originality/value: The study provides a significant contribution to research and professional practice, while no comprehensive studies have been conducted on the various phases of the relocation process. The findings of this study are genuine to keep professionals and practitioners on the ball managing their workplace relocations, overcoming their unforeseen struggles, resourcefully and efficiently.