Satish C. Muluk

Satish C. Muluk

Auto-generated profile, based on publicly available information

Satish C. Muluk

Division of Vascular Surgery, Allegheny Health Network, Pittsburgh, Pa

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2005 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
CSChristine M Scotti
Christine M Scotti
ASAlexander D Shkolnik
Alexander D Shkolnik
SMSatish C Muluk
Satish C Muluk
Ender A FinolEnder A Finol
Ender A Finol
Background: Abdominal aortic aneurysm (AAA) is a prevalent disease which is of significant concern because of the morbidity associated with the continuing expansion of the abdominal aorta and its ultimate rupture. The transient interaction between blood flow and the wall contributes to wall stress which, if it exceeds the failure strength of the dilated arterial wall, will lead to aneurysm rupture. Utilizing a computational approach, the biomechanical environment of virtual AAAs can be evaluated to study the affects of asymmetry and wall thickness on this stress, two parameters that contribute to increased risk of aneurysm rupture. Methods: Ten virtual aneurysm models were created with five different asymmetry parameters ranging from β = 0.2 to 1.0 and either a uniform or variable wall thickness to study the flow and wall dynamics by means of fully coupled fluid-structure interaction (FSI) analyses. The AAA wall was designed to have a (i) uniform 1.5 mm thickness or (ii) variable thickness ranging from 0.5 – 1.5 mm extruded normally from the boundary surface of the lumen. These models were meshed with linear hexahedral elements, imported into a commercial finite element code and analyzed under transient flow conditions. The method proposed was then compared with traditional computational solid stress techniques on the basis of peak wall stress predictions and cost of computational effort. Results: The results provide quantitative predictions of flow patterns and wall mechanics as well as the effects of aneurysm asymmetry and wall thickness heterogeneity on the estimation of peak wall stress. These parameters affect the magnitude and distribution of Von Mises stresses; varying wall thickness increases the maximum Von Mises stress by 4 times its uniform thickness counterpart. A pre-peak systole retrograde flow was observed in the AAA sac for all models, which is due to the elastic energy stored in the compliant arterial wall and the expansion force of the artery during systole. Conclusion: Both wall thickness and geometry asymmetry affect the stress exhibited by a virtual AAA. Our results suggest that an asymmetric AAA with regional variations in wall thickness would be exposed to higher mechanical stresses and an increased risk of rupture than a more fusiform AAA with uniform wall thickness. Therefore, it is important to accurately reproduce vessel geometry and wall thickness in computational predictions of AAA biomechanics.

1 February 2001 in Journal of Vascular Surgery
Verified
Journal Article
Closed access
SMSatish C. Muluk
Satish C. Muluk
VMVisala S. Muluk
Visala S. Muluk
MKMary E. Kelley
Mary E. Kelley
JWJeffrey C. Whittle
Jeffrey C. Whittle
JTJill A. Tierney
Jill A. Tierney
MMMichel S. Makaroun
Michel S. Makaroun

12 June 2013 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
SCSantanu Chandra
Santanu Chandra
SRSamarth S. Raut
Samarth S. Raut
AJAnirban Jana
Anirban Jana
RBRobert Biederman
Robert Biederman
MDMark Doyle
Mark Doyle
Ender A FinolEnder A Finol
Ender A Finol
Rupture risk assessment of abdominal aortic aneurysms (AAA) by means of biomechanical analysis is a viable alternative to the traditional clinical practice of using a critical diameter for recommending elective repair. However, an accurate prediction of biomechanical parameters, such as mechanical stress, strain, and shear stress, is possible if the AAA models and boundary conditions are truly patient specific. In this work, we present a complete fluid-structure interaction (FSI) framework for patient-specific AAA passive mechanics assessment that utilizes individualized inflow and outflow boundary conditions. The purpose of the study is two-fold: (1) to develop a novel semiautomated methodology that derives velocity components from phase-contrast magnetic resonance images (PC-MRI) in the infrarenal aorta and successfully apply it as an inflow boundary condition for a patient-specific fully coupled FSI analysis and (2) to apply a one-way–coupled FSI analysis and test its efficiency compared to transient computational solid stress and fully coupled FSI analyses for the estimation of AAA biomechanical parameters. For a fully coupled FSI simulation, our results indicate that an inlet velocity profile modeled with three patient-specific velocity components and a velocity profile modeled with only the axial velocity component yield nearly identical maximum principal stress (σ1), maximum principal strain (ε1), and wall shear stress (WSS) distributions. An inlet Womersley velocity profile leads to a 5% difference in peak σ1, 3% in peak ε1, and 14% in peak WSS compared to the three-component inlet velocity profile in the fully coupled FSI analysis. The peak wall stress and strain were found to be in phase with the systolic inlet flow rate, therefore indicating the necessity to capture the patient-specific hemodynamics by means of FSI modeling. The proposed one-way–coupled FSI approach showed potential for reasonably accurate biomechanical assessment with less computational effort, leading to differences in peak σ1, ε1, and WSS of 14%, 4%, and 18%, respectively, compared to the axial component inlet velocity profile in the fully coupled FSI analysis. The transient computational solid stress approach yielded significantly higher differences in these parameters and is not recommended for accurate assessment of AAA wall passive mechanics. This work demonstrates the influence of the flow dynamics resulting from patient-specific inflow boundary conditions on AAA biomechanical assessment and describes methods to evaluate it through fully coupled and one-way–coupled fluid-structure interaction analysis.

1 October 2013 in European Journal of Vascular and Endovascular Surgery
Verified
Journal Article
Closed access
SMS.C. Muluk
S.C. Muluk
AHA.T. Hirsch
A.T. Hirsch
ETE.C. Taffe
E.C. Taffe

27 October 2003 in Archives of internal medicine (1960)
Verified
Journal Article
Open access
PDF file
DBDaniel J. Bertges
Daniel J. Bertges
VMVisala Muluk
Visala Muluk
JWJeffrey Whittle
Jeffrey Whittle
MKMary Kelley
Mary Kelley
DMDavid S. MacPherson
David S. MacPherson
SMSatish C. Muluk
Satish C. Muluk
SEVERITY OF CAROTID stenosis is known to be an important predictor of transient ischemic attacks (TIAs) and cerebrovascular accidents (CVAs) in both symptomatic and asymptomatic patients.1-5 For symptomatic patients with severe disease, clinical decision making is often guided by the finding that there is a significant reduction in CVA risk following carotid endarterectomy (CEA).1,3 However, the benefit of CEA is not as great for asymptomatic patients2,6; therefore, better prediction of future ischemic neurological events would be of great value in improving patient selection for intervention.

22 November 2021 in Journal of Vascular Surgery Cases, Innovations and Techniques
Verified
Journal Article
Open access
SMSatish C. Muluk
Satish C. Muluk
MEMahmoud Elrakhawy
Mahmoud Elrakhawy
BCBart Chess
Bart Chess
CRCarlos Rosales
Carlos Rosales
VGVikash Goel
Vikash Goel
We report our initial experience using the intraoperative positioning system (IOPS), a novel endovascular navigation system that does not require contrast or radiation, in the treatment of chronic mesenteric ischemia (CMI). We used IOPS to help treat three of four consecutive patients with CMI. Technical problems prevented successful use in one patient. For the patients for whom IOPS was used effectively, catheterization of the mesenteric artery was accomplished more quickly than for the patient for whom IOPS was not effective. Our experience has shown that IOPS can be safely and effectively used for CMI and can reduce the contrast load and radiation dose.