Chongyu Jin

Chongyu Jin

Auto-generated profile, based on publicly available information

Chongyu Jin

Electrical Engineering Department, Harbin Institute of Technology (HIT), Harbin, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
DPDonghua Pan
Donghua Pan
SLShengxin Lin
Shengxin Lin
YJYinxi Jin
Yinxi Jin
JWJinting Wang
Jinting Wang
CJChongyu Jin
Chongyu Jin
Liyi LiLiyi Li
Liyi Li
Magnetic positioning technology is safe, practical, and cost-effective, and is getting increasingly emphasized in many fields such as biomedicine and geophysics. However, magnetic positioning methods have a positioning-inaccuracy-area (positioning error is significantly greater than that in the adjacent area). This paper establishes an Omni-posture error model to explore the variation law of the positioning error and finds that the included angle φ between the magnetic moment vector and the position vector determines the distribution of the positioning error. Using wireless communication to send commands and adjusting the current vector to change φ, we propose an avoidance method of positioning-inaccuracy-area (AMP). Simulation results show that when using the AMP to track a wireless capsule endoscope (WCE) with an arbitrary posture, the positioning error is 5.5 mm and the orientation error is 1.64°. The experimental results in a magnetically shielded room show that the positioning error of the AMP is 12 mm, which reduces the positioning error before avoidance by 95.5%. The simulation and experimental results both prove that the AMP can effectively avoid the positioning-inaccuracy-area of the magnetic positioning method, thereby improving the positioning accuracy.

24 August 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
CJChongyu Jin
Chongyu Jin
DPDonghua Pan
Donghua Pan
YCYitao Chen
Yitao Chen
SLShengxin Lin
Shengxin Lin
YWYiding Wang
Yiding Wang
Liyi LiLiyi Li
Liyi Li
Standard gradient magnetic flux (GMF) is widely used in the research and development of biotechnology, and error calibration of magnetic detection systems, and can directly support the development of life sciences, geological exploration, ocean exploration, space exploration, and other fields. Because a magnetic shielding room (MSR) can create a noise-free environment (within a static magnetic field less than 0.2nT and magnetic noise less than 10fT/√Hz), the construction of a standard magnetic gradient source in MSR will further promote the detection accuracy of related technologies. The existing gradient coil design methods can’t achieve the best uniformity in a certain uniform zone. In addition, when the gradient coils are placed in the MSR, the magnetic and conductive materials of the MSR will further deteriorate the uniformity. In this essay, the calculation model for the magnetic flux gradient value of the coil in the MSR is formulated firstly. On the basis of the calculation model, a design method for gradient coil with optimal uniformity in any uniform zone is proposed. The new method can realize the design of improving the uniformity index for any uniform zone, and take advantage of the adverse factor of ferromagnetic boundary conditions introduced by MSR to make the gradient uniformity better. Meanwhile, in the research process of the design method, the coil volume utilization and efficiency are introduced into the design evaluation process through analysis, avoiding the singular result that the volume utilization and efficiency are less than 1/10 of the normal result, and the limitations of the design ability of the new method have been significantly improved. Finally, the core parameters of the new coil at different working conditions are summarized, which can be intended for leading the rapid gradient coils’ design. The validity and accuracy of the new approach are proved by finite element simulation and experiment. And the experiment shows that the uniformity of the new coil is improved from 44.79% of the traditional coil to 23.47% with ΔG decreasing by 47.6%.

22 September 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
XDXinping Dai
Xinping Dai
DPDonghua Pan
Donghua Pan
YCYitao Chen
Yitao Chen
CJChongyu Jin
Chongyu Jin
Liyi LiLiyi Li
Liyi Li
The static magnetic field within magnetically shielded room (MSR) is a main factor restricting magnetoencephalography (MEG) if measurements for a moving subject with optically pumped magnetometers (OPMs) are carried out. Existing compensation methods can control it at the nanotesla or sub-nanotesla level, which can meet the measurement during subjects' stationary or small-scale movements. However, this still brings significant motion artifacts. This article studies the spatial distribution characteristics of static residual magnetic fields inside the MSR, and proposes a hybrid coil compensation system. A magnetic field component model is established for all types of coils in the hybrid coil compensation system at various points in space. Then, the distribution pattern of the minimum sensor array and the number of sensors for real-time observation of the magnetic field in space were discussed. Combined with a genetic algorithm (GA), the coil current is optimized to achieve large-scale measurement of motion MEG. The static magnetic field in the central volume of 60×60×15 cm3 is monitored, and the three static magnetic field components within areas of 10×20 cm2, 30×40 cm2 and 50×60 cm2 were accurately controlled to less than 55 pT, 95 pT and 170 pT respectively. Finally, the reliability of the compensation system and algorithm control is verified through auditory stimulation experiments, laying a foundation for the study of motion MEG.

1 January 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YCYitao Chen
Yitao Chen
SLShengxin Lin
Shengxin Lin
CJChongyu Jin
Chongyu Jin
XDXinping Dai
Xinping Dai
DPDonghua Pan
Donghua Pan
Liyi LiLiyi Li
Liyi Li

4 September 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YWYiding Wang
Yiding Wang
SLShengxin Lin
Shengxin Lin
CJChongyu Jin
Chongyu Jin
DPDonghua Pan
Donghua Pan
YCYitao Chen
Yitao Chen
Liyi LiLiyi Li
Liyi Li
Optically pumped magnetometers (OPMs) have emerged as a promising magnetic sensor for magnetoencephalography and magnetocardiography (MEG & MCG), owing to their low cost, high spatiotemporal resolution and excellent magnetic-field sensitivity. Self-shielded coils—which generate a highly uniform internal field while rapidly decaying external fields—serve as critical roles in OPM development: as in-MSR (magnetic shielding room) standard magnetic sources, they enable distortion-free uniform field for OPM calibration; as in-probe modulation magnetic sources, they provide stable, low-crosstalk modulation field. The external filed decay and internal field uniformity of these coils are key performance metrics. To overcome the limitations inherent in conventional cylindrical self-shielded coil topologies, this paper proposes a dual-layer spherical self-shielded coil structure and optimizes its geometry with respect to the field of target region. Theoretical analysis shows that, compared to common cylindrical designs, the proposed spherical structure reduces the minimum crosstalk-free distance by 50% when used as a modulation source, and expands the uniform field region by a factor of 1.9 when used as a standard source within MSR. Experimental validation corroborates these predictions, proving the efficacy of the spherical coil topology and optimization methodology in advancing OPM performance and suppressing crosstalk.

7 April 2026 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
YWYiding Wang
Yiding Wang
SLShengxin Lin
Shengxin Lin
DPDonghua Pan
Donghua Pan
CJChongyu Jin
Chongyu Jin
YCYitao Chen
Yitao Chen
Liyi LiLiyi Li
Liyi Li
The inversion of multiple magnetic dipoles plays a critical role in applications such as geological exploration and spacecraft magnetic modeling. The primary challenges include an unknown number of magnetic sources, high sensitivity to noise, and low inversion accuracy. In this paper, we propose a novel three-dimensional inversion method for multiple magnetic dipole models that integrates deep-learning-based prior analysis with a penalty function optimization strategy. A lightweight convolutional attention network, termed MGTI-net, is developed to extract prior information from the invariants of the magnetic gradient tensor, thereby enabling accurate identification of the dipole count and providing preliminary estimates of their positions. By incorporating a penalty function into an improved least squares estimation framework, the proposed method robustly inverts the spatial positions and magnetic moments of the dipoles. Simulation results demonstrate that MGTI-net can reliably determine the number of dipoles in a three-dimensional space and maintain a classification accuracy above 75% even under 50% relative random noise interference. Moreover, the improved least squares estimation can constrain the position and magnetic moment errors within 0.01 m and 0.1 A·m², respectively, under 15% relative noise, reducing the error by more than one order of magnitude compared with conventional least squares methods. Experimental findings corroborate the simulation analysis, confirming that the new approach can accurately recover magnetic source parameters.