P. Yeates

P. Yeates

Auto-generated profile, based on publicly available information

P. Yeates

Dublin City Univ, Sch Phys Sci, Dublin 9, Ireland

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2007 in Nature Photonics
Verified
Journal Article
Closed access
PDF file
WAW. Ackermann
W. Ackermann
GAG. Asova
G. Asova
VAV. Ayvazyan
V. Ayvazyan
AAA. Azima
A. Azima
NBN. Baboi
N. Baboi
KZK. Zapfe
K. Zapfe

14 July 2006 in Physical Review A
Verified
Journal Article
Open access
PDF file
MMM. Meyer
M. Meyer
DCD. Cubaynes
D. Cubaynes
POP. O’keeffe
P. O’keeffe
HLH. Luna
H. Luna
PYP. Yeates
P. Yeates
JFJ. Feldhaus
J. Feldhaus
Two-photon ionization of atomic helium has been measured by combining femtosecond extreme-ultraviolet pulses from the free-electron laser in Hamburg (FLASH at DESY) with intense light pulses from a synchronized neodymium-doped yttrium lithium fluoride laser. Sidebands appear in the photoelectron spectra when the two laser pulses overlap in both space and time. Their intensity exhibits a characteristic dependence on the relative time delay between the ionizing and the dressing pulses and provides an inherent time marker for time-resolved pump-probe experiments. The measurements of the sidebands are in good agreement with theoretical predictions and allow for a direct analysis of two-photon ionization, free from processes related to interference between multiple quantum paths.

26 March 2007 in Applied Physics Letters
Verified
Journal Article
Open access
PDF file
PRP. Radcliffe
P. Radcliffe
SDStefan Düsterer
Stefan Düsterer
AAA. Azima
A. Azima
HRH. Redlin
H. Redlin
JFJ. Feldhaus
J. Feldhaus
MMM. Meyer
M. Meyer
Two-color above threshold ionization of helium and xenon has been used to analyze the synchronization between individual pulses of the femtosecond extreme ultraviolet (XUV) free electron laser in Hamburg and an independent intense 120fs mode-locked Ti:sapphire laser. Characteristic sidebands appear in the photoelectron spectra when the two pulses overlap spatially and temporally. The cross-correlation curve points to a 250fs rms jitter between the two sources at the experiment. A more precise determination of the temporal fluctuation between the XUV and infrared pulses is obtained through the analysis of the single-shot sideband intensities.

1 June 2006 in Optics Letters
Verified
Journal Article
Closed access
PDF file
SDStefan Düsterer
Stefan Düsterer
PRP. Radcliffe
P. Radcliffe
GGG. Geloni
G. Geloni
UJU. Jastrow
U. Jastrow
MKM. Kuhlmann
M. Kuhlmann
MMM. Meyer
M. Meyer
Because of the stochastic nature of self-amplified spontaneous emission (SASE), it is crucial to measure for single pulses the spectral characteristics of ultrashort pulses from the vacuum ultraviolet free electron laser (FLASH) at DESY, Germany. To meet this particular challenge, we have employed both photon and photoelectron spectroscopy. Each FEL pulse is composed of an intense and spectrally complex fundamental, centered at a photon energy of about 38.5eV, with a bandwidth of 0.5% accompanied by higher harmonics, each carrying an intensity of typically 0.3 to 0.6% of that of the fundamental. The correlation between the harmonics and the fundamental is in remarkable agreement with a simple statistical model of SASE FEL radiation.

1 December 2007 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
PRP. Radcliffe
P. Radcliffe
SDStefan Düsterer
Stefan Düsterer
AAA. Azima
A. Azima
WLW.B. Li
W.B. Li
EPE. Plönjes
E. Plönjes
MMM. Meyer
M. Meyer

1 November 2010 in Journal of Applied Physics
Verified
Journal Article
Closed access
PDF file
PYP. Yeates
P. Yeates
Eugene KennedyEugene Kennedy
Eugene Kennedy
Laser plasma plumes were generated in aluminum rectangular cavities of fixed depth (6 mm) and varying height (2.0, 1.5, and 1.0 mm). Space and time resolved visible emission spectroscopy, gated intensified visible imaging, and Langmuir probe diagnostics were utilized to diagnose the evolution of the confined plasma plumes in comparison to freely expanding plasma plume generated from ablation of a planar target. The constrained plasma behavior displayed a multiphase history. Early stage interactions (t<100 ns) resulted in enhanced continuum and line emission, shockwave formation and plasma plume rebound. Later phase, long duration plasma-surface interactions (t>160 ns) resulted in sustained “decay,” i.e., a rapid termination of continuum emission, in concert with decreases in peak electron density (Ne) and plasma temperature (T) . This later phase originates from loss mechanisms which bleed the plasma plume of thermal energy and charged particles. These loss mechanisms increase in magnitude as the duration of the plasma-surface interaction increases. The transition from enhancement phase, originating from hydrodynamic containment, and plasma-surface collisions, to decay phase is described and occurs for each cavity at a different point in the space time history.