Hongwei Xie

Hongwei Xie

Auto-generated profile, based on publicly available information

Hongwei Xie

Department of Occupational Health and Radiation Protection, Zhejiang Provincial Center for Disease Control and Prevention, Hangzhou 310051, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 October 2023 in Safety
Verified
Journal Article
Open access
PDF file
JRJia Ren
Jia Ren
HXHongwei Xie
Hongwei Xie
YHYong Hu
Yong Hu
YHYu Hong
Yu Hong
HZHua Zou
Hua Zou
Gao xiangjingGao xiangjing
Gao xiangjing
To analyze the predominant frequencies of hearing threshold shift and the prevalence of hearing loss related to the co-exposure to noise and solvents. A systematic review and meta-analysis were performed by retrieving published articles from Web of Science, PubMed, Scopus, Embase, and ProQuest until July 2023. Data were extracted in line with the Cochrane Collaboration Handbook, and the Newcastle-Ottawa Scale and Agency for Healthcare Research and Quality were used to assess the studies’ quality. The meta-analysis was used to estimate the odds ratios (ORs) with 95% confidence interval (CI). I2 and Q statistics were used to prove the heterogeneity. A total of 22 selected studies (9948 workers), six cohort studies and 16 cross-sectional studies were included. The results revealed that 43.7%, 41.3%, and 53.6% of the participants presented with hearing loss due to noise exposure, solvent exposure, and combined exposure to noise and solvent, respectively. The workers exposed to both noise and solvents had a higher risk of hearing loss than those exposed to noise (overall weighted odds ratio [OR]: 1.76) or solvents (overall-weighted OR: 2.02) alone. The poorer hearing threshold in the combined noise and solvents exposure group was mainly at high frequencies (3, 4, 6, and 8 kHz), with a peak of 29.47 dB HL at 6 kHz. The noise-exposed group’s peak hearing threshold was 28.87 dB HL at 4 kHz. The peak hearing threshold of the solvent-exposed group was 28.65 dB HL at 6 kHz. The workers exposed to noise and solvent simultaneously had a higher prevalence of hearing loss than those exposed to solvents. Co-exposure to noise and solvents increases the odds of hearing loss. The dominant hearing threshold changes occurred at 3, 4, 6, and 8 kHz, and the peak value appeared at 6 kHz in workers co-exposed to noise and solvents.