Robert Krumm

Robert Krumm

Auto-generated profile, based on publicly available information

Robert Krumm

Department of Urology, University of California, San Francisco, 550 16th Street, Box 1695, San Francisco, CA, 94158, United States, 1 5109126645

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 January 2026 in JMIR Bioinformatics and Biotechnology
Verified
Journal Article
Open access
MCMarvin N Carlisle
Marvin N Carlisle
WPWilliam A Pace
William A Pace
ALAndrew W Liu
Andrew W Liu
RKRobert Krumm
Robert Krumm
JCJanet E Cowan
Janet E Cowan
AOAnobel Y Odisho
Anobel Y Odisho
Background: The manual abstraction of unstructured clinical data is often necessary for granular clinical outcomes research but is time consuming and can be of variable quality. Large language models (LLMs) show promise in medical data extraction yet integrating them into research workflows remains challenging and poorly described. Objective: This study aimed to develop and integrate an LLM-based system for automated data extraction from unstructured electronic health record (EHR) text reports within an established clinical outcomes database. Methods: We implemented a generative artificial intelligence pipeline (UODBLLM) utilizing a flexible language model interface that supports various LLM implementations, including Health Insurance Portability and Accountability Act-compliant cloud services and local open-source models. We used extensible markup language (XML)-structured prompts and integrated using an open database connectivity interface to generate structured data from clinical documentation in the EHR. We evaluated the UODBLLM’s performance on the completion rate, processing time, and extraction capabilities across multiple clinical data elements, including quantitative measurements, categorical assessments, and anatomical descriptions, using sample magnetic resonance imaging (MRI) reports as test cases. System reliability was tested across multiple batches to assess scalability and consistency. Results: Piloted against MRI reports, UODBLLM processed 1800 clinical documents with a 100% completion rate and an average processing time of 8.90 seconds per report. The token utilization averaged 2692 tokens per report, with an input-to-output ratio of approximately 13:2, resulting in a processing cost of US $0.009 per report. UODBLLM had consistent performance across 18 batches of 100 reports each and completed all processing in 4.45 hours. From each report, UODBLLM extracted 16 structured clinical elements, including prostate volume, prostate-specific antigen values, Prostate Imaging Reporting and Data System scores, clinical staging, and anatomical assessments. All extracted data were automatically validated against predefined schemas and stored in standardized JSON format. Conclusions: We demonstrated the successful integration of an LLM-based extraction system within an existing clinical outcomes database, achieving rapid, comprehensive data extraction at minimal cost. UODBLLM provides a scalable, efficient solution for automating clinical data extraction while maintaining protected health information security. This approach could significantly accelerate research timelines and expand feasible clinical studies, particularly for large-scale database projects.

1 January 2026 in JCO Clinical Cancer Informatics
Verified
Journal Article
Closed access
AOAnobel Y. Odisho
Anobel Y. Odisho
ALAndrew W. Liu
Andrew W. Liu
WPWilliam A. Pace
William A. Pace
MCMarvin N. Carlisle
Marvin N. Carlisle
RKRobert Krumm
Robert Krumm
MCMatthew R. Cooperberg
Matthew R. Cooperberg
PURPOSE: Radiology reports are stored as plain text in most electronic health records, rendering the data computationally inaccessible. Large language models are powerful tools for analyzing unstructured text but relatively untested in urologic oncology. We aimed to develop a pipeline to extract data from plain text prostate magnetic resonance imaging (MRI) reports using GPT4.0 and compare the accuracy to manually abstracted data. METHODS: We developed a data pipeline using a secure, enterprise-wide deployment of OpenAI's GPT-4.0 to automatically extract data elements from prostate MRI report text when presented with prostate MRI reports. Identical prompts and reports were sent multiple times to determine response variability. We extracted 15 data elements per report and compared accuracy to a manually abstracted gold standard. RESULTS: Across 424 prostate MRI reports, GPT-4.0 response accuracy was consistently above 95%. Individual field accuracies were 98.3% (96.3%-99.3%) for prostate-specific antigen density, 97.4% (95.4%-98.7%) for extracapsular extension, and 98.1% (96.3%-99.2%) for TNM stage, and had a median of 98.1% (96.3%-99.2%), a mean of 97.2% (95.2%-98.3%), and a range of 99.8% (98.7%-100.0%) for number of suspicious lesions to 87.7% (84.2%-90.7%) for identification of lesion location in the base of the prostate. Response variability over five repeated runs ranged from 0.14% to 3.61%, differed based on the data element extracted ( P < .001), and was inversely correlated with accuracy ( P < .001). In disagreements between manual and GPT-4.0 extracted data, GPT-4.0 responses were more often deemed correct by an additional reviewer. CONCLUSION: GPT-4.0 had high accuracy with low variability in extracting data points from prostate cancer MRI reports with low upfront programming requirements. This represents an effective tool to expedite medical data extraction for clinical and research use cases.