1 January 2014 in Magnetic Resonance in Medical Sciences
Signal intensity and image contrast differ between postmortem magnetic resonance (PMMR) images and images acquired from the living body. We sought to achieve sufficient fat suppression with short-tau inversion recovery (STIR) PMMR imaging by optimizing inversion time (TI). We subjected 37 deceased adult patients to PMMR imaging at 1.5 tesla 8 to 60 hours after confirmation of death and measured T1 values of areas of subcutaneous fat with relaxation time maps. Rectal temperature (RT) measured immediately after PMMR ranged from 6 to 31°C. We used Pearson's correlation coefficient to analyze the relationship between T1 and relaxation time (RT). We compared STIR images from 4 cadavers acquired with a TI commonly used in the living body and another TI calculated from the linear regression of T1 and RT. T1 values of subcutaneous fat ranged from 89.4 to 182.2 ms. There was a strong, positive, and significant correlation between T1 and RT (r = 0.91, P < 0.0001). The regression expression for the relationship was T1 = 2.6*RT + 90 at a field strength of 1.5T. The subcutaneous fat signal was suppressed more effectively with the optimized TI. The T1 value of subcutaneous fat in PMMR correlates linearly with body temperature. Using this correlation to determine TI, fat suppression with PMMR STIR imaging can be easily improved.
1 January 2022 in Journal of Medical Physics
Radiofrequency (RF) field (B1) mapping by combining the double-angle method (DAM) and T1 correction was investigated. The signal intensities S1 and S2 acquired by flip angle (FA) α and double FA 2α at short repetition time (TR) were converted to a signal intensity at TR=∞ by T1 correction. Then, these were used for DAM calculation. The T1 values are measured from two different images acquired with different TRs based on the saturation recovery (SR) method preliminarily. The effects of imaging parameters for T1 estimation and measured FA were investigated using CuSO4-doped water phantoms. A two-dimensional gradient echo type echo planar imaging pulse sequence was used. T1 values obtained by the 2-SR method were underestimated compared to the multipoint inversion recovery method. FA error was less than 5% when the appropriate imaging parameters were used. The acquisition time could be shortened to under 25 s by the use of T1-corrected DAM.
1 January 2007 in Magnetic Resonance in Medical Sciences
Purpose: To propose a simple and useful method for correcting nonuniformity of high-field (3 Tesla) T1-weighted spin-echo (SE) images based on a B1 field map estimated from gradient recalled echo (GRE) signals. Methods: To estimate B1 inhomogeneity, spoiled gradient recalled echo (SPGR) images were collected using a fixed repetition time of 70 ms, flip angles of 45 and 90 degrees, and echo times of 4.8 and 10.4 ms. Selection of flip angles was based on the observation that the relative intensity changes in SPGR signals were very similar among different tissues at larger flip angles than the Ernst angle. Accordingly, spatial irregularity that was observed on a signal ratio map of the SPGR images acquired with these 2 flip angles was ascribed to inhomogeneity of the B1 field. Dual echo time was used to eliminate T2* effects. The ratio map that was acquired was scaled to provide an intensity correction map for SE images. Both phantom and volunteer studies were performed using a 3T magnetic resonance scanner to validate the method. Results: In the phantom study, the uniformity of the T1-weighted SE image improved by 23%. Images of human heads also showed practically sufficient improvement in the image uniformity. Conclusion: The present method improves the image uniformity of high-field T1-weighted SE images.
1 November 2009 in Acta Radiologica
Background: Susceptibility-weighted imaging (SWI) is utilized in magnetic resonance (MR) venography and other applications, but can include artifacts caused by the phase-masking process. Purpose: To demonstrate risks of filter processes used in making phase masks for SWI, and to propose a simple method for reducing artifacts. Material and Methods: Phase linearity related to echo time (TE) was evaluated for the original phase and high-pass-filtered phase using a CuSO4-doped water phantom. Effect of filter size of the Hanning window and background homogeneity were also evaluated in a phantom study. Use of a phase mask generated by data with differing magnitudes of TE was attempted in a human study. Shorter TE was used for making the phase mask, and the number of multiplications was increased. As short and long TEs were necessary simultaneously for phase mask and T2* contrast, a dual-echo technique was used. Results: Linearity of TE and phase value collapsed, and an unexpected negative phase appeared in the high-pass-filtered phase. Using a short-TE phase mask, phase-aliasing artifacts were reduced and visibility of deep veins was equivalent to that under conventional methods with an increased number of multiplications. Conclusion: Use of a short-echo phase mask in SWI is useful for reducing artifacts.
1 December 2010 in Radiological Physics and Technology
1 January 2000 in Japanese Journal of Radiological Technology