27 October 2022 in Clinical Chemistry and Laboratory Medicine (CCLM)
Biological variation (BV) data have many applications in laboratory medicine. However, these depend on the availability of relevant and robust BV data fit for purpose. BV data can be obtained through different study designs, both by experimental studies and studies utilizing previously analysed routine results derived from laboratory databases. The different BV applications include using BV data for setting analytical performance specifications, to calculate reference change values, to define the index of individuality and to establish personalized reference intervals. In this review, major achievements in the area of BV from last decade will be presented and discussed. These range from new models and approaches to derive BV data, the delivery of high-quality BV data by the highly powered European Biological Variation Study (EuBIVAS), the Biological Variation Data Critical Appraisal Checklist (BIVAC) and other standards for deriving and reporting BV data, the EFLM Biological Variation Database and new applications of BV data including personalized reference intervals and measurement uncertainty.
19 February 2024 in Clinical Chemistry and Laboratory Medicine (CCLM)
Analytical performance specifications (APS) are typically established through one of three models: (i) outcome studies, (ii) biological variation (BV), or (iii) state-of-the-art. Presently, The APS can, for most measurands that have a stable concentration, be based on BV. BV based APS, defined for imprecision, bias, total allowable error and allowable measurement uncertainty, are applied to many different processes in the laboratory. When calculating APS, it is important to consider the different APS formulae, for what setting they are to be applied and if they are suitable for the intended purpose. In this opinion paper, we elucidate the background, limitations, strengths, and potential intended applications of the different BV based APS formulas. When using BV data to set APS, it is important to consider that all formulae are contingent on accurate and relevant BV estimates. During the last decade, efficient procedures have been established to obtain reliable BV estimates that are presented in the EFLM biological variation database. The database publishes detailed BV data for numerous measurands, global BV estimates derived from meta-analysis of quality-assured studies of similar study design and automatic calculation of BV based APS.
19 September 2023 in Clinical Chemistry
FTfor the IFCC Working Group on Commutability in Metrological Traceability
for the IFCC Working Group on Commutability in Metrological Traceability
+12
It is important for external quality assessment materials (EQAMs) to be commutable with clinical samples; i.e., they should behave like clinical samples when measured using end-user clinical laboratory in vitro diagnostic medical devices (IVD-MDs). Using commutable EQAMs makes it possible to evaluate metrological traceability and/or equivalence of results between IVD-MDs. The criterion for assessing commutability of an EQAM between 2 IVD-MDs is that its result should be within the prediction interval limits based on the statistical distribution of the clinical sample results from the 2 IVD-MDs being compared. The width of the prediction interval is, among other things, dependent on the analytical performance characteristics of the IVD-MDs. A presupposition for using this criterion is that the differences in nonselectivity between the 2 IVD-MDs being compared are acceptable. An acceptable difference in nonselectivity should be small relative to the analytical performance specifications used in the external quality assessment scheme. The acceptable difference in nonselectivity is used to modify the prediction interval criterion for commutability assessment. The present report provides recommendations on how to establish a criterion for acceptable commutability for EQAMS, establish the difference in nonselectivity that can be accepted between IVD-MDs, and perform a commutability assessment. The report also contains examples for performing a commutability assessment of EQAMs.
19 October 2020 in Clinical Chemistry and Laboratory Medicine (CCLM)
OVon behalf of the European Federation of Clinical Chemistry and Laboratory Medicine Working Group on Biological Variation
on behalf of the European Federation of Clinical Chemistry and Laboratory Medicine Working Group on Biological Variation
+6
Objectives: Reliable biological variation (BV) data are required for the clinical use of tumor markers in the diagnosis and monitoring of treatment effects in cancer. The European Biological Variation Study (EuBIVAS) was established by the EFLM Biological Variation Working Group to deliver BV data for clinically important measurands. In this study, EuBIVAS-based BV estimates are provided for cancer antigen (CA) 125, CA 15-3, CA 19-9, carcinoembryonic antigen, cytokeratin-19 fragment, alpha‐fetoprotein and human epididymis protein 4. Methods: Subjects from five European countries were enrolled in the study, and weekly samples were collected from 91 healthy individuals (53 females and 38 males; 21–69 years old) for 10 consecutive weeks. All samples were analyzed in duplicate within a single run. After excluding outliers and homogeneity analysis, the BVs of tumor markers were determined by CV-ANOVA on trend-corrected data, when relevant (Røraas method). Results: Marked individuality was found for all tumor markers. CYFRA 21-1 was the measurand with the highest index of individuality (II) at 0.67, whereas CA 19-9 had the lowest II at 0.07. The CV
I
s of HE4, CYFRA 21-1, CA 19-9, CA 125 and CA 15-3 of pre- and postmenopausal females were significantly different from each other. Conclusions: This study provides updated BV estimates for several tumor markers, and the findings indicate that marked individuality is characteristic. The use of reference change values should be considered when monitoring treatment of patients by means of tumor markers.
1 June 2015 in BMC Health Services Research
In order to improve recruitment of patients to the Norwegian diabetes register for adults, a questionnaire was designed to collect data directly from patients. The main aim of this study was to assess the agreement of questionnaire data with data reported to the Register from health care personnel during routine consultations. Patient data were obtained by sending a questionnaire with 27 of the 41 Register variables to 3714 members of the Norwegian Diabetes Association. Questionnaire data were compared with data already in the Register. Paired t-tests, percentages of total agreement, percentages of “positive” answers and kappa coefficients (k) were used for comparing data. Of the 1645 replies (44.3 %), the Register already had data on 324 patients for comparison. Response rate for most variables was better from patients (ranging from 76–100 %) compared with health care professionals (33–100 %). For 17 of 25 assessable variables including diabetes duration, height, weight, HbA1c, drug treatment and several diabetes complications, agreement was substantial or better with kappa >0.60. Data on family history of premature heart disease (k–0.59), foot examination (k = 0.26), foot ulcer (k = 0.32) and arterial surgery (k = 0.24) seemed to be difficult to answer by patients, whereas data on physical activity and self-monitoring of glucose seemed to be better when reported by patients. Patient response rate was acceptable, and data had good concordance with data from health care professionals for most variables. However, registers using patient questionnaires should compare questionnaire data with data from professionals at regular intervals.