19 April 2023 in Optics Express
A near-infrared (NIR) sub-ppm level photoacoustic sensor for hydrogen sulfide (H2S) using a differential Helmholtz resonator (DHR) as the photoacoustic cell (PAC) was presented. The core detection system was composed of a NIR diode laser with a center wavelength of 1578.13 nm, an Erbium-doped optical fiber amplifier (EDFA) with an output power of ∼120 mW, and a DHR. Finite element simulation software was used to analyze the influence of the DHR parameters on the resonant frequency and acoustic pressure distribution of the system. Through simulation and comparison, the volume of the DHR was 1/16 that of the conventional H-type PAC for a similar resonant frequency. The performance of the photoacoustic sensor was evaluated after optimizing the DHR structure and modulation frequency. The experimental results showed that the sensor had an excellent linear response to the gas concentration and the minimum detection limit (MDL) for H2S detection in differential mode can reach 460.8 ppb.
16 September 2019 in IEEE Access
Gas pressure regulators are widely applied in natural gas pipeline networks, correspondingly, establishing an efficient fault diagnosis approach of regulators plays a critical role in optimizing the safety and reliability of pipeline network systems. In our paper, considering that the outlet pressure signals of gas regulators are nonstationary and nonlinear, we propose a fault diagnosis approach combining a complete ensemble empirical mode decomposition with adaptive noise (CEEMDAN) and fuzzy c-means (FCM) clustering to classify three typical faults of gas regulators. First, we propose to apply the CEEMDAN approach for decomposing intrinsic mode functions (IMFs). Then feature vectors of the typical faults are established by Hilbert marginal spectrum (HMS) of IMFs. Finally, we adopt cluster centers and feature clustering algorithm to distinguish the types of faults. The experimental results indicate the high performance of the present fault diagnosis approach. The membership degrees of test samples obtained from the CEEMDAN algorithm are optimized to be within 0.9 to 1.
11 April 2024 in Optics Letters
The introduction of cantilever-based fiber-optic microphones (FOMs) has proven to be effective in acoustic sensing. Further improvements in cantilevers face two key constraints: the challenge of achieving minimal sizes with sufficient reflective area and the trade-off between sensitivity and response bandwidth. Herein, we present a geometry optimization framework for a cantilever-based FOM that addresses this issue. Employing drumstick-shaped cantilevers housed within a Fabry–Perot (F–P) interferometric structure, we showcase a heightened sensitivity of 302.8 mV/Pa at 1 kHz and a minimum detectable acoustic pressure (MDP) of 2.35 µPa/Hz. Notably, these metrics outperform those of the original rectangular cantilever with identical dimensions. Furthermore, our proposed cantilever effectively mitigates the reduction in resonance frequencies, thereby improving the response bandwidth. This geometry optimization framework offers considerable design flexibility and scalability, making it especially suitable for high-performance acoustic sensing applications.
13 June 2023 in Optics Express
Transducer components are crucial in optimizing the sensitivity of microphones. Cantilever structure is commonly used as a structural optimization technique. Here, we present a novel Fabry-Perot (F-P) interferometric fiber-optic microphone (FOM) using a hollow cantilever structure. The proposed hollow cantilever aims to reduce the effective mass and spring constant of the cantilever, thereby enhancing the sensitivity of the FOM. Experimental results demonstrate that the proposed structure outperforms the original cantilever design in terms of sensitivity. The sensitivity and minimum detectable acoustic pressure level (MDP) can reach 91.40 mV/Pa and 6.20 µPa/Hz at 1.7 kHz, respectively. Notably, the hollow cantilever provides an optimization framework for highly sensitive FOMs.
30 January 2025 in Sensors and Actuators B: Chemical
10 September 2024 in IEEE Sensors Journal
The leakage of SF 6 gas in high pressure equipment will cause great risk, so it is of great significance to the development of SF 6 gas concentration detection system. Non-dispersive infrared (NDIR) technology offers several advantages, including miniaturization, low power consumption, simple structure, affordability, and non-destructive testing, making it well-suited for establishing large-scale sensor networks. However, while efforts have primarily focused on enhancing the detection limit and accuracy of NDIR sensors, shortening their response time has remained a persistent challenge. This is because sensor stability and response time are inherently linked to the length of the gas cell, presenting a dilemma where optimizing one aspect often compromises the other. Short gas cells offer faster response times but sacrifice stability, whereas long gas cells prioritize stability but elongate response times. To address this issue, this paper introduces a novel solution: a dual gas cell NDIR sensor coupled with the regression Kalman data fusion algorithm. The results demonstrate that the fused data exhibit a response time equivalent to that of a short gas cell, surpassing that of a long gas cell by 20%. Moreover, the stability achieved is on par with that of a long gas cell, with the variance limited to less than 0.2. This innovative approach represents a significant advancement in SF 6 leak detection technology, reconciling the conventional trade-off between response time and stability.