Tomasz S. Kaminski

Tomasz S. Kaminski

Auto-generated profile, based on publicly available information

Tomasz S. Kaminski

Department of Molecular Biology, Institute of Biochemistry, Faculty of Biology, University of Warsaw, Miecznikowa 1, 02-096 Warsaw, Poland

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2016 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
TKTomasz S. Kaminski
Tomasz S. Kaminski
OSOtt Scheler
Ott Scheler
PGPiotr Garstecki
Piotr Garstecki
Droplet microfluidics has rapidly emerged as one of the key technologies opening up new experimental possibilities in microbiology.

31 August 2017 in Chemical Society Reviews
Verified
Journal Article
Open access
PDF file
TKT. S. Kaminski
T. S. Kaminski
PGPiotr Garstecki
Piotr Garstecki
Droplet microfluidics is a relatively new and rapidly evolving field of science focused on studying the hydrodynamics and properties of biphasic flows at the microscale, and on the development of systems for practical applications in chemistry, biology and materials science.

27 June 2022 in Nature Biotechnology
Verified
Journal Article
Open access
PDF file
FSFredrik Salmen
Fredrik Salmen
JJJoachim De Jonghe
Joachim De Jonghe
TKTomasz S. Kaminski
Tomasz S. Kaminski
AAAnna Alemany
Anna Alemany
GPGuillermo E. Parada
Guillermo E. Parada
AOAlexander van Oudenaarden
Alexander van Oudenaarden
Most methods for single-cell transcriptome sequencing amplify the termini of polyadenylated transcripts, capturing only a small fraction of the total cellular transcriptome. This precludes the detection of many long non-coding, short non-coding and non-polyadenylated protein-coding transcripts and hinders alternative splicing analysis. We, therefore, developed VASA-seq to detect the total transcriptome in single cells, which is enabled by fragmenting and tailing all RNA molecules subsequent to cell lysis. The method is compatible with both plate-based formats and droplet microfluidics. We applied VASA-seq to more than 30,000 single cells in the developing mouse embryo during gastrulation and early organogenesis. Analyzing the dynamics of the total single-cell transcriptome, we discovered cell type markers, many based on non-coding RNA, and performed in vivo cell cycle analysis via detection of non-polyadenylated histone genes. RNA velocity characterization was improved, accurately retracing blood maturation trajectories. Moreover, our VASA-seq data provide a comprehensive analysis of alternative splicing during mammalian development, which highlighted substantial rearrangements during blood development and heart morphogenesis.

8 February 2012 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
KCKrzysztof Churski
Krzysztof Churski
TKTomasz S. Kaminski
Tomasz S. Kaminski
Slawomir JakielaSlawomir Jakiela
Slawomir Jakiela
Wojciech Kamysz, Pharm. D.Wojciech Kamysz, Pharm. D.
Wojciech Kamysz, Pharm. D.
WBWioletta Barańska-Rybak
Wioletta Barańska-Rybak
PGPiotr Garstecki
Piotr Garstecki
We report an automated microfluidic platform for ‘digitally’ screening the composition space of droplets containing cocktails of small molecules and demonstrate the features of this system by studying epistatic interactions between antibiotics and Escherichia coli ATCC 25922. This system has several key characteristics: (i) it uses small (<100 μL) samples of liquids and suspensions of bacteria that are introduced directly into the chip; (ii) it generates a sequence of droplets with compositions, including reagents and bacterial cell suspensions that are programmed by the user; (iii) it exports the sequence of droplets to an external segment of tubing that is subsequently disconnected for incubation and storage; and (iv) after incubation of bacteria in droplets, the droplets are injected into a second device equipped with an in-line fiber optic spectrophotometer that measures cell growth. The system generates and fuses droplets with precise (<1% in standard deviation) control of liquid volumes and of the concentrations of input substrates. We demonstrate the application of this technology in determining the minimum inhibitory concentration and pair-wise interactions of ampicillin, tetracycline, and chloramphenicol against E. coli. The experiments consumed small volumes of reagents and required minutes to create the droplets and several hours for their incubation and analysis.

5 July 2013 in Angewandte Chemie International Edition
Verified
Journal Article
Closed access
PDF file
Slawomir JakielaSlawomir Jakiela
Slawomir Jakiela
TKTomasz S. Kaminski
Tomasz S. Kaminski
OCOlgierd Cybulski
Olgierd Cybulski
DWDouglas B. Weibel
Douglas B. Weibel
PGPiotr Garstecki
Piotr Garstecki

8 August 2023 in Nature Communications
Verified
Journal Article
Open access
PDF file
JJJoachim De Jonghe
Joachim De Jonghe
TKTomasz S. Kaminski
Tomasz S. Kaminski
DMDavid B. Morse
David B. Morse
MTMarcin Tabaka
Marcin Tabaka
AEAnna L. Ellermann
Anna L. Ellermann
FHFlorian Hollfelder
Florian Hollfelder
Droplet microfluidic methods have massively increased the throughput of single-cell sequencing campaigns. The benefit of scale-up is, however, accompanied by increased background noise when processing challenging samples and the overall RNA capture efficiency is lower. These drawbacks stem from the lack of strategies to enrich for high-quality material or specific cell types at the moment of cell encapsulation and the absence of implementable multi-step enzymatic processes that increase capture. Here we alleviate both bottlenecks using fluorescence-activated droplet sorting to enrich for droplets that contain single viable cells, intact nuclei, fixed cells or target cell types and use reagent addition to droplets by picoinjection to perform multi-step lysis and reverse transcription. Our methodology increases gene detection rates fivefold, while reducing background noise by up to half. We harness these properties to deliver a high-quality molecular atlas of mouse brain development, despite starting with highly damaged input material, and provide an atlas of nascent RNA transcription during mouse organogenesis. Our method is broadly applicable to other droplet-based workflows to deliver sensitive and accurate single-cell profiling at a reduced cost.