SUMMARY OBJECTIVE: To describe the characteristics of patients treated at a level III surgical Neonatal Intensive Care Unit outside of a maternity service and analyze possible risk factors for mortality in this population. METHODS: A retrospective cohort study evaluating patients admitted to a level III surgical Neonatal Intensive Care Unit from June/2015 to November/2017. Univariate analysis was performed by the Chi-square test and T-student test or Mann-Whitney test. Multivariate analysis by logistic regression was performed including in the model the variables with a P-value <0.2 in univariate analysis. Kaplan-Meier curve and Log-Rank test were performed using the variables that were statistically associated with death in the multivariate analysis. A significance level of a=5% and an error B=80% were adopted. RESULTS: During this period, 246 patients were admitted to this service. 58 (23.8%) patients died, with a mean time until death of 18 days. Half of the patients had a clinical diagnosis of sepsis (50.6%), blood culture was positive in 25.2%, and gram-positive bacteria (48.4%) were the main pathogens isolated. The variables that remained in the final model after multivariate analysis were diagnosis of congenital heart disease (OR = 4.5; p = 0.016), clinical diagnosis of sepsis (OR = 8.1; p = 0.000), and isolation of gram-positive bacteria in blood culture (OR = 3.9; p = 0.006). CONCLUSION: The level III surgical Neonatal Intensive Care Unit outside of a maternity service has a different profile of morbidity and mortality, and death was associated with the diagnosis of congenital heart disease, the clinical diagnosis of sepsis, and the isolation of gram-positive bacteria in the blood culture
8 April 2024 in Brazilian Journal of Otorhinolaryngology
This is a case report of a rare airway Foreign Body (FB), the first reported case of an extruded prosthesis of previous cervical spine arthrodesis still attached to the wall of the hypopharynx, obstructing the airway, and requiring immediate removal. A 56-year-old man with a history of previous cervical arthrodesis (C3-C7). He presented anterior displacement of the Cage Device and erosion of the posterior wall of the hypopharynx, with the prosthesis causing partial obstruction of the larynx. After the Neurosurgery and Radiology team determined that there were no risks of cervical spine instability, we were able to remove the device in the operating room using Laryngoscope and McGill forceps with success. After proper evaluation of the case, we were able to remove the foreign body uneventfully. Given the rarity of this complication, we hope this case report can assist in the treatment and management of future cases.