Moninne Howlett

Moninne Howlett

Auto-generated profile, based on publicly available information

Moninne Howlett

Department of Pharmacy, Children's Health Ireland at Crumlin, Dublin, Ireland

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2016 in Pediatric Critical Care Medicine
Verified
Journal Article
Closed access
JHJohn C. Hayden
John C. Hayden
CBCormac Breatnach
Cormac Breatnach
DDDermot R. Doherty
Dermot R. Doherty
MHMartina Healy
Martina Healy
MHMoninne M. Howlett
Moninne M. Howlett
GCGráinne Cousins
Gráinne Cousins
Children in PICUs normally require analgesics and sedatives to maintain comfort, safety, and cooperation with interventions. α2-agonists (clonidine and dexmedetomidine) have been described as adjunctive (or alternative) sedative agents alongside opioids and benzodiazepines. This systematic review aimed to determine whether α2-agonists were effective in maintaining patients at a target sedation score over time compared with a comparator group. We also aimed to determine whether concurrent use of α2-agonists provided opioid-sparing effects. A systematic search was performed using the Cochrane Central Register of Controlled Trials, PubMed, EMBASE, CINAHL, and LILACS. We included randomized controlled trials of children in PICU treated with clonidine or dexmedetomidine for the indication of sedation. Two authors independently screened articles for inclusion. Six randomized controlled trials with sufficient data were identified and critically appraised. Three clonidine trials (two vs placebo and one vs midazolam) and three dexmedetomidine trials (two vs fentanyl, one vs midazolam) were included. Due to study heterogeneity it was not possible to pool studies. A narrative synthesis is provided. Reporting of study results using the outcome "time maintained at target sedation score' for clonidine or dexmedetomidine was poor. Only one trial compared clonidine with midazolam using a sedation score outcome. This study was underpowered to demonstrate equivalence to midazolam as a sedative. The adjunctive use of clonidine demonstrated significant decreases in opioid use in neonates but not in older groups. Clonidine dose was inconsistent between studies. Dexmedetomidine demonstrated an opioid-sparing effect in two small trials. Further studies, including dose-finding studies and studies with sedation score-based outcomes, are needed.

18 March 2020 in Applied Clinical Informatics
Verified
Journal Article
Closed access
PDF file
MHMoninne M. Howlett
Moninne M. Howlett
EBEileen Butler
Eileen Butler
KLKaren M. Lavelle
Karen M. Lavelle
BCBrian J. Cleary
Brian J. Cleary
CBCormac V. Breatnach
Cormac V. Breatnach
Background Increased use of health information technology (HIT) has been advocated as a medication error reduction strategy. Evidence of its benefits in the pediatric setting remains limited. In 2012, electronic prescribing (ICCA, Philips, United Kingdom) and standard concentration infusions (SCIs)—facilitated by smart-pump technology—were introduced into the pediatric intensive care unit (PICU) of an Irish tertiary-care pediatric hospital. Objective The aim of this study is to assess the impact of the new technology on the rate and severity of PICU prescribing errors and identify technology-generated errors. Methods A retrospective, before and after study design, was employed. Medication orders were reviewed over 24 weeks distributed across four time periods: preimplementation (Epoch 1); postimplementation of SCIs (Epoch 2); immediate postimplementation of electronic prescribing (Epoch 3); and 1 year postimplementation (Epoch 4). Only orders reviewed by a clinical pharmacist were included. Prespecified definitions, multidisciplinary consensus and validated grading methods were utilized. Results A total of 3,356 medication orders for 288 patients were included. Overall error rates were similar in Epoch 1 and 4 (10.2 vs. 9.8%; p = 0.8), but error types differed (p < 0.001). Incomplete and wrong unit errors were eradicated; duplicate orders increased. Dosing errors remained most common. A total of 27% of postimplementation errors were technology-generated. Implementation of SCIs alone was associated with significant reductions in infusion-related prescribing errors (29.0% [Epoch 1] to 14.6% [Epoch 2]; p < 0.001). Further reductions (8.4% [Epoch 4]) were identified after implementation of electronically generated infusion orders. Non-infusion error severity was unchanged (p = 0.13); fewer infusion errors reached the patient (p < 0.01). No errors causing harm were identified. Conclusion The limitations of electronic prescribing in reducing overall prescribing errors in PICU have been demonstrated. The replacement of weight-based infusions with SCIs was associated with significant reductions in infusion prescribing errors. Technology-generated errors were common, highlighting the need for on-going research on HIT implementation in pediatric settings.

15 July 2022 in Drug Safety
Verified
Journal Article
Closed access
PDF file
ASAdam Sutherland
Adam Sutherland
MJMatthew David Jones
Matthew David Jones
MHMoninne Howlett
Moninne Howlett
SASara Arenas-Lopez
Sara Arenas-Lopez
APArif Patel
Arif Patel
BFBryony Dean Franklin
Bryony Dean Franklin

16 November 2023 in International Journal of Clinical Pharmacy
Verified
Journal Article
Closed access
PDF file
MHMoninne M. Howlett
Moninne M. Howlett
SSSharon Sutton
Sharon Sutton
EMEimear L. McGrath
Eimear L. McGrath
CBCormac V. Breatnach
Cormac V. Breatnach

5 August 2020 in Applied Clinical Informatics
Verified
Journal Article
Closed access
PDF file
MHMoninne M. Howlett
Moninne M. Howlett
CBCormac V. Breatnach
Cormac V. Breatnach
EBErika Brereton
Erika Brereton
BCBrian J. Cleary
Brian J. Cleary
Background Processes for delivery of high-risk infusions in pediatric intensive care units (PICUs) are complex. Standard concentration infusions (SCIs), smart-pumps, and electronic prescribing are recommended medication error reduction strategies. Implementation rates in Europe lag behind those in the United States. Since 2012, the PICU of an Irish tertiary pediatric hospital has been using a smart-pump SCI library, interfaced with electronic infusion orders (Philips ICCA). The incidence of infusion errors is unknown. Objectives To determine the frequency, severity, and distribution of smart-pump infusion errors in PICUs. Methods Programmed infusions were directly observed at the bedside. Parameters were compared against medication orders and autodocumented infusion data. Identified deviations were categorized as medication errors or discrepancies. Error rates (%) were calculated as infusions with errors and errors per opportunities for error (OEs). Predefined definitions, multidisciplinary consensus and grading processes were employed. Results A total of 1,023 infusions for 175 patients were directly observed over 27 days between February and September 2017. The drug library accommodated 96.5% of infusions. Compliance with the drug library was 98.9%. A total of 133 infusions had ≥1 error (13.0%); a further 58 (5.7%) had ≥1 discrepancy. From a total of 4,997 OEs, 153 errors (3.1%) and 107 discrepancies (2.1%) were observed. Undocumented bolus doses were most commonly identified (n = 81); this was the only deviation in 36.1% (n = 69) of infusions. Programming errors were rare (0.32% OE). Errors were minor, with just one requiring minimal intervention to prevent harm. Conclusion The error rates identified are low compared with similar studies, highlighting the benefits of smart-pumps and autodocumented infusion data in PICUs. A range of quality improvement opportunities has been identified.

7 December 2018 in BMC Medical Informatics and Decision Making
Verified
Journal Article
Open access
PDF file
MHMoninne M. Howlett
Moninne M. Howlett
BCBrian J. Cleary
Brian J. Cleary
CBCormac V. Breatnach
Cormac V. Breatnach
The use of health information technology (HIT) to improve patient safety is widely advocated by governmental and safety agencies. Electronic-prescribing and smart-pump technology are examples of HIT medication error reduction strategies. The introduction of new errors on HIT implementation is, however, also recognised. To determine the impact of HIT interventions, clear medication error definitions are required. This study aims to achieve consensus on defining as medication errors a range of either technology-generated, or previously unaddressed infusion-related scenarios, common in the paediatric intensive care setting. This study was conducted in a 23-bed paediatric intensive care unit (PICU) of an Irish tertiary paediatric hospital. A modified Delphi technique was employed: previously undefined medication-incidents were identified by retrospective review of voluntary incident reports and clinical pharmacist interventions; a multidisciplinary expert panel scored each incident using a 9-point Likert scale over a number of iterative rounds; levels of agreement were assessed to produce a list of medication errors. Differences in scoring between healthcare professionals were assessed. Seventeen potential errors or ‘scenarios’ requiring consensus were identified, 13 of which related to technology recently implemented into the PICU. These were presented to a panel of 37 participants, comprising of doctors, nurses and pharmacists. Consensus was reached to define as errors all reported smart-pump scenarios (n = 6) and those pertaining to the pre-electronic process of prescribing weight-based paediatric infusions (n = 4). Of 7 electronic-prescribing scenarios, 4 were defined as errors, 2 were deemed not to be and consensus could not be achieved for the last. Some differences in scoring between healthcare professionals were found, but were only significant (p < 0.05) for two and three scenarios in consensus rounds 1 and 2 respectively. The list of medication errors produced using the Delphi technique highlights the diversity of previously undefined medication errors in PICU. The increased complexity of electronic-prescribing processes is evident from the difficulty in achieving consensus on those scenarios. Reducing ambiguity in defining medication errors should assist future research on the impact of HIT medication safety initiatives in critical care. The increasing use of HIT and associated new errors will necessitate further similar studies.