Claudia Lindner

Claudia Lindner

Auto-generated profile, based on publicly available information

Claudia Lindner

Division of Informatics, Imaging and Data Sciences, The University of Manchester, Manchester, UK

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2016 in Medical Image Analysis
Verified
Journal Article
Open access
Ching-Wei WangChing-Wei Wang
Ching-Wei Wang
CHCheng-Ta Huang
Cheng-Ta Huang
JLJia-Hong Lee
Jia-Hong Lee
CLChung-Hsing Li
Chung-Hsing Li
SCSheng-Wei Chang
Sheng-Wei Chang
CLClaudia Lindner
Claudia Lindner
Dental radiography plays an important role in clinical diagnosis, treatment and surgery. In recent years, efforts have been made on developing computerized dental X-ray image analysis systems for clinical usages. A novel framework for objective evaluation of automatic dental radiography analysis algorithms has been established under the auspices of the IEEE International Symposium on Biomedical Imaging 2015 Bitewing Radiography Caries Detection Challenge and Cephalometric X-ray Image Analysis Challenge. In this article, we present the datasets, methods and results of the challenge and lay down the principles for future uses of this benchmark. The main contributions of the challenge include the creation of the dental anatomy data repository of bitewing radiographs, the creation of the anatomical abnormality classification data repository of cephalometric radiographs, and the definition of objective quantitative evaluation for comparison and ranking of the algorithms. With this benchmark, seven automatic methods for analysing cephalometric X-ray image and two automatic methods for detecting bitewing radiography caries have been compared, and detailed quantitative evaluation results are presented in this paper. Based on the quantitative evaluation results, we believe automatic dental radiography analysis is still a challenging and unsolved problem. The datasets and the evaluation software will be made available to the research community, further encouraging future developments in this field. (http://www-o.ntust.edu.tw/~cweiwang/ISBI2015/).

18 December 2014 in IEEE Transactions on Pattern Analysis and Machine Intelligence
Verified
Journal Article
Closed access
CLClaudia Lindner
Claudia Lindner
PBPaul A. Bromiley
Paul A. Bromiley
MIMircea C. Ionita
Mircea C. Ionita
TCTim F. Cootes
Tim F. Cootes
A widely used approach for locating points on deformable objects in images is to generate feature response images for each point, and then to fit a shape model to these response images. We demonstrate that Random Forest regression-voting can be used to generate high quality response images quickly. Rather than using a generative or a discriminative model to evaluate each pixel, a regressor is used to cast votes for the optimal position of each point. We show that this leads to fast and accurate shape model matching when applied in the Constrained Local Model framework. We evaluate the technique in detail, and compare it with a range of commonly used alternatives across application areas: the annotation of the joints of the hands in radiographs and the detection of feature points in facial images. We show that our approach outperforms alternative techniques, achieving what we believe to be the most accurate results yet published for hand joint annotation and state-of-the-art performance for facial feature point detection.

20 September 2016 in Scientific Reports
Verified
Journal Article
Open access
CLClaudia Lindner
Claudia Lindner
Ching-Wei WangChing-Wei Wang
Ching-Wei Wang
CHCheng-Ta Huang
Cheng-Ta Huang
CLChung-Hsing Li
Chung-Hsing Li
SCSheng-Wei Chang
Sheng-Wei Chang
TCTim F. Cootes
Tim F. Cootes
Cephalometric tracing is a standard analysis tool for orthodontic diagnosis and treatment planning. The aim of this study was to develop and validate a fully automatic landmark annotation (FALA) system for finding cephalometric landmarks in lateral cephalograms and its application to the classification of skeletal malformations. Digital cephalograms of 400 subjects (age range: 7–76 years) were available. All cephalograms had been manually traced by two experienced orthodontists with 19 cephalometric landmarks, and eight clinical parameters had been calculated for each subject. A FALA system to locate the 19 landmarks in lateral cephalograms was developed. The system was evaluated via comparison to the manual tracings, and the automatically located landmarks were used for classification of the clinical parameters. The system achieved an average point-to-point error of 1.2 mm, and 84.7% of landmarks were located within the clinically accepted precision range of 2.0 mm. The automatic landmark localisation performance was within the inter-observer variability between two clinical experts. The automatic classification achieved an average classification accuracy of 83.4% which was comparable to an experienced orthodontist. The FALA system rapidly and accurately locates and analyses cephalometric landmarks in lateral cephalograms, and has the potential to significantly improve the clinical work flow in orthodontic treatment.

12 April 2013 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
CLC. Lindner
C. Lindner
STS. Thiagarajah
S. Thiagarajah
MWMark Wilkinson
Mark Wilkinson
TCThe Consortium
The Consortium
GWG. A. Wallis
G. A. Wallis
TCTimothy Francis Cootes
Timothy Francis Cootes
Extraction of bone contours from radiographs plays an important role in disease diagnosis, preoperative planning, and treatment analysis. We present a fully automatic method to accurately segment the proximal femur in anteroposterior pelvic radiographs. A number of candidate positions are produced by a global search with a detector. Each is then refined using a statistical shape model together with local detectors for each model point. Both global and local models use Random Forest regression to vote for the optimal positions, leading to robust and accurate results. The performance of the system is evaluated using a set of 839 images of mixed quality. We show that the local search significantly outperforms a range of alternative matching techniques, and that the fully automated system is able to achieve a mean point-to-curve error of less than 0.9 mm for 99% of all 839 images. To the best of our knowledge, this is the most accurate automatic method for segmenting the proximal femur in radiographs yet reported.

1 January 2012
Verified
Book Chapter
Closed access
PDF file
TCTim F. Cootes
Tim F. Cootes
MIMircea C. Ionita
Mircea C. Ionita
CLClaudia Lindner
Claudia Lindner
PSPatrick Sauer
Patrick Sauer

1 October 2013 in Osteoarthritis and Cartilage
Verified
Journal Article
Closed access
CLC Lindner
C Lindner
STS Thiagarajah
S Thiagarajah
MWMark Wilkinson
Mark Wilkinson
ACarcOGEN Consortium
arcOGEN Consortium
GWG A Wallis
G A Wallis
TCTimothy Francis Cootes
Timothy Francis Cootes