1 March 2016 in Cellular and Molecular Gastroenterology and Hepatology
Conventional white-light colonoscopy aims to reduce the incidence and mortality of colorectal cancer (CRC). CRC has been found to arise from missed polypoid and flat precancerous lesions. We aimed to establish proof-of-concept for real-time endoscopic imaging of colonic adenomas using a near-infrared peptide that is specific for claudin-1. We used gene expression profiles to identify claudin-1 as a promising early CRC target, and performed phage display against the extracellular loop of claudin-1 (amino acids 53-80) to identify the peptide RTSPSSR. With a Cy5.5 label, we characterized binding parameters and showed specific binding to human CRC cells. We collected in vivo near-infrared fluorescence images endoscopically in the CPC;Apc mouse, which develops colonic adenomas spontaneously. With immunofluorescence, we validated specific peptide binding to adenomas from the proximal human colon. We found a 2.5-fold increase in gene expression for claudin-1 in human colonic adenomas compared with normal. We showed specific binding of RTSPSSR to claudin-1 in knockdown and competition studies, and measured an affinity of 42 nmol/L and a time constant of 1.2 minutes to SW620 cells. In the mouse, we found a significantly higher target-to-background ratio for both polypoid and flat adenomas compared with normal by in vivo images. On immunofluorescence, we found significantly greater intensity for human adenomas (mean ± SD, 25.5 ± 14.0) vs normal (mean ± SD, 9.1 ± 6.0) and hyperplastic polyps (mean ± SD, 3.1 ± 3.7; P = 10-5 and 8 × 10-12, respectively), and for sessile serrated adenomas (mean ± SD, 20.1 ± 13.3) vs normal and hyperplastic polyps (P = .02 and 3 × 10-7, respectively). Claudin-1 is overexpressed in premalignant colonic lesions, and can be detected endoscopically in vivo with a near-infrared, labeled peptide.
1 May 2016 in Gastroenterology
The multimodal video colonoscope (CF-Y0012, Olympus) was designed for forward viewing with 2 separate standard definition detectors to collect either white light or fluorescence images, shown in schematic (Figure 1A). All modes of illumination are delivered through 2 standard fiber optic light guides. A filter (520-600 nm) is located between the fluorescence objective and detector to allow light from fluorescein isothiocyanate (FITC) to pass. Reflectance images (540-560 nm) can be collected that are co-registered with fluorescence. The white light and fluorescence/reflectance images are collected at 20 and 10 frames/sec, respectively (Figure 1B–D), and all images are displayed on the monitor at 30 frames/sec. A summary of the optical and instrument parameters is shown (Figure 1E). The maximum divergence angle and depth-of-field of all imaging modes are similar to that of a conventional colonoscope and allow for the proximal colon to be rapidly visualized. A standard nozzle (air/water nozzle) provides air for insufflation and water to clear the lens. The dimensions of the distal end (14.8 mm), working length (1680 mm), and total length (2010 mm) are identical to that of a conventional video colonoscope. Videos are recorded in MP4 format with 8-bit intensity (0-255 gray levels) using an image digitizer (IMH-10, Olympus). The entire system, including the endoscope, light source, video processor, and image digitizer, is contained on a portable instrument cart. Figure 1 Multimodal video colonoscope. (A) Schematic of prototype instrument. Separate standard definition detectors are used to collect either (B) white light (WL) or (C) fluorescence images. A filter located in between the fluorescence objective and detector passes light from fluorescein isothiocyanate. (D) Reflectance images collected with the same detector are co-registered with fluorescence. (E) Summary of optical parameters. White light and fluorescence/reflectance images are collected at 20 and 10 frames/sec, respectively. aw, air/water nozzle. View Large Image Figure Viewer Download Hi-res image Download (PPT)
1 April 2019 in Optics & Laser Technology