Moritz H. Albrecht

Moritz H. Albrecht

Auto-generated profile, based on publicly available information

Moritz H. Albrecht

University Hospital Frankfurt, Department of Diagnostic and Interventional Radiology, Theodor-Stern-Kai 7, 60590 Frankfurt, Germany

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2019 in Radiology
Verified
Journal Article
Closed access
MAMoritz H. Albrecht
Moritz H. Albrecht
Thomas Josef VoglThomas Josef Vogl
Thomas Josef Vogl
SMSimon S. Martin
Simon S. Martin
JNJohn W. Nance
John W. Nance
TDTaylor M. Duguay
Taylor M. Duguay
USU. Joseph Schoepf
U. Joseph Schoepf
A growing body of literature encourages routine implementation of virtual monoenergetic imaging for dual-energy CT because it affords fewer beam-hardening artifacts, reduced iodine dose, and better... In this article, the authors discuss the technical background and summarize the current body of literature regarding virtual monoenergetic (VM) images derived from dual-energy CT data, which can be...

28 January 2020 in European Radiology Experimental
Verified
Journal Article
Open access
PDF file
CBChristian Booz
Christian Booz
IYIbrahim Yel
Ibrahim Yel
JWJulian L. Wichmann
Julian L. Wichmann
SBSabine Boettger
Sabine Boettger
AKAhmed Al Kamali
Ahmed Al Kamali
BBBoris Bodelle
Boris Bodelle
Background: Bone age (BA) assessment performed by artificial intelligence (AI) is of growing interest due to improved accuracy, precision and time efficiency in daily routine. The aim of this study was to investigate the accuracy and efficiency of a novel AI software version for automated BA assessment in comparison to the Greulich-Pyle method. Methods: Radiographs of 514 patients were analysed in this retrospective study. Total BA was assessed independently by three blinded radiologists applying the GP method and by the AI software. Overall and gender-specific BA assessment results, as well as reading times of both approaches, were compared, while the reference BA was defined by two blinded experienced paediatric radiologists in consensus by application of the Greulich-Pyle method. Results: Mean absolute deviation (MAD) and root mean square deviation (RSMD) were significantly lower between AI-derived BA and reference BA (MAD 0.34 years, RSMD 0.38 years) than between reader-calculated BA and reference BA (MAD 0.79 years, RSMD 0.89 years; p < 0.001). The correlation between AI-derived BA and reference BA (r = 0.99) was significantly higher than between reader-calculated BA and reference BA (r = 0.90; p < 0.001). No statistical difference was found in reader agreement and correlation analyses regarding gender (p = 0.241). Mean reading times were reduced by 87% using the AI system. Conclusions: A novel AI software enabled highly accurate automated BA assessment. It may improve efficiency in clinical routine by reducing reading times without compromising the accuracy compared with the Greulich-Pyle method.

1 September 2018 in European Journal of Radiology
Verified
Journal Article
Closed access
LLLukas Lenga
Lukas Lenga
RCRouben Czwikla
Rouben Czwikla
JWJulian L. Wichmann
Julian L. Wichmann
DLDoris Leithner
Doris Leithner
MAMoritz H. Albrecht
Moritz H. Albrecht
SMSimon S. Martin
Simon S. Martin

3 September 2021 in European Radiology Experimental
Verified
Journal Article
Open access
PDF file
TDTommaso D’angelo
Tommaso D’angelo
MAMoritz H. Albrecht
Moritz H. Albrecht
DCDanilo Caudo
Danilo Caudo
SMSilvio Mazziotti
Silvio Mazziotti
TVThomas J. Vogl
Thomas J. Vogl
CBChristian Booz
Christian Booz
Dual-energy CT (DECT) has emerged into clinical routine as an imaging technique with unique postprocessing utilities that improve the evaluation of different body areas. The virtual non-calcium (VNCa) reconstruction algorithm has shown beneficial effects on the depiction of bone marrow pathologies such as bone marrow edema. Its main advantage is the ability to substantially increase the image contrast of structures that are usually covered with calcium mineral, such as calcified vessels or bone marrow, and to depict a large number of traumatic, inflammatory, infiltrative, and degenerative disorders affecting either the spine or the appendicular skeleton. Therefore, VNCa imaging represents another step forward for DECT to image conditions and disorders that usually require the use of more expensive and time-consuming techniques such as magnetic resonance imaging, positron emission tomography/CT, or bone scintigraphy. The aim of this review article is to explain the technical background of VNCa imaging, showcase its applicability in the different body regions, and provide an updated outlook on the clinical impact of this technique, which goes beyond the sole improvement in image quality.

5 October 2021 in European Radiology Experimental
Verified
Journal Article
Open access
PDF file
VKVitali Koch
Vitali Koch
NHNils Große Hokamp
Nils Große Hokamp
MAMoritz H. Albrecht
Moritz H. Albrecht
LGLeon D. Gruenewald
Leon D. Gruenewald
IYIbrahim Yel
Ibrahim Yel
CBChristian Booz
Christian Booz
Background: Dual-source dual-energy computed tomography (DECT) offers the potential for opportunistic osteoporosis screening by enabling phantomless bone mineral density (BMD) quantification. This study sought to assess the accuracy and precision of volumetric BMD measurement using dual-source DECT in comparison to quantitative CT (QCT). Methods: A validated spine phantom consisting of three lumbar vertebra equivalents with 50 (L1), 100 (L2), and 200 mg/cm3 (L3) calcium hydroxyapatite (HA) concentrations was scanned employing third-generation dual-source DECT and QCT. While BMD assessment based on QCT required an additional standardised bone density calibration phantom, the DECT technique operated by using a dedicated postprocessing software based on material decomposition without requiring calibration phantoms. Accuracy and precision of both modalities were compared by calculating measurement errors. In addition, correlation and agreement analyses were performed using Pearson correlation, linear regression, and Bland-Altman plots. Results: DECT-derived BMD values differed significantly from those obtained by QCT (p < 0.001) and were found to be closer to true HA concentrations. Relative measurement errors were significantly smaller for DECT in comparison to QCT (L1, 0.94% versus 9.68%; L2, 0.28% versus 5.74%; L3, 0.24% versus 3.67%, respectively). DECT demonstrated better BMD measurement repeatability compared to QCT (coefficient of variance < 4.29% for DECT, < 6.74% for QCT). Both methods correlated well to each other (r = 0.9993; 95% confidence interval 0.9984–0.9997; p < 0.001) and revealed substantial agreement in Bland-Altman plots. Conclusions: Phantomless dual-source DECT-based BMD assessment of lumbar vertebra equivalents using material decomposition showed higher diagnostic accuracy compared to QCT.

1 November 2020 in European Journal of Radiology
Verified
Journal Article
Closed access
CBChristian Booz
Christian Booz
JNJochen Noeske
Jochen Noeske
MAMoritz H. Albrecht
Moritz H. Albrecht
LLLukas Lenga
Lukas Lenga
SMSimon S. Martin
Simon S. Martin
JWJulian L. Wichmann
Julian L. Wichmann