19 December 2017 in IEEE Transactions on Power Systems
Power system operation will encounter numerous variabilities as the proliferation of renewable energy continues. Such random events will require the evaluation of corresponding variables and the assessment of their impacts on the monitoring and the control of stochastic power systems. In this paper, a global sensitivity analysis (GSA) method is proposed to perform a priority ranking of renewable energy variabilities that will affect the voltage stability of power systems. First, a probabilistic model for the load margin calculation is presented considering the renewable power generation. Then, GSA is applied to models with correlated random input variables and the importance index is designed for evaluating the impacts of such variables. Next, the stochastic response surface method (SRMS) is adopted in GSA to improve the computation efficiency of the proposed evaluation method. Finally, the overall procedure is presented to identify critical variables that can affect the variability of load margins in voltage stability analyses. The proposed method is applied to power systems with a large penetration of renewable power and the influences of critical variabilities on voltage stability are analyzed. In this paper, the proposed method is tested using the IEEE 9-bus and the IEEE 118-bus systems, and its accuracy is compared with those of the local sensitivity analysis method and the commonly used GSA methods.
24 January 2019 in IEEE Transactions on Sustainable Energy
This paper proposes a data-driven optimization method to solve the integrated energy and reserve dispatch problem with variable and correlated renewable energy generation. The proposed method applies the kernel density estimation to establish an ambiguity set of continuous multivariate probability distributions and the optimization model for the integrated dispatch is formulated as a combination of stochastic and robust optimization problems. First, a risk-averse two-stage stochastic optimization model is formulated to hedge the distributional uncertainty. Next, the second-stage worst-case expectation is evaluated, using the equivalent model reformulation, as a combination of conditional value-at-risk (CVaR) and the extreme cost in the worst-case scenario. The CVaR is calculated using a scenario-based stochastic optimization problem. After describing the wind power correlation in ellipsoidal uncertainty sets, the robust optimization problem for finding the worst-case cost is cast into a mixed-integer second-order cone programming problem. Finally, the column-and-constraint generation method is employed to solve the proposed risk-averse two-stage problem. The proposed method is tested on the 6-bus and IEEE 118-bus systems and validated by comparing the results with those of conventional stochastic and robust optimization methods.
15 August 2018 in IEEE Transactions on Power Systems
In this paper, a hierarchical control scheme is proposed to improve the optimal economic operation of hybrid AC/DC microgrids. The proposed scheme consists of two layers: 1) The lower layer which is an iterative process embedded into the droop-based frequency/voltage regulation for solving the economic dispatch problem. The equal incremental cost criterion is applied in AC and DC sections separately; 2) The upper layer in which the power exchange between the two sections is regulated by the primary, secondary and tertiary IC coordination to ensure the economic and secure operations of hybrid AC/DC microgrids are maintained. In this hierarchical control structure, AC and DC sections are coordinated to regulate the microgrid frequency and voltages while implementing a droop scheme in a distributed plug and play architecture. In the proposed scheme, the centralized control is implemented in the tertiary IC coordination to minimize the total generation cost in a microgrid by removing the difference in incremental costs between the AC and DC sections. The effectiveness of the proposed scheme is verified by using a scaled-down hybrid AC/DC microgrid through time-domain simulations in PSCAD/EMTDC.
10 May 2022 in IEEE Transactions on Sustainable Energy
Probabilistic forecasting of photovoltaic (PV) power provides system operators with pertinent information on the uncertainty of PV power generation. This paper proposes a spatio-temporal probabilistic forecasting model based on monotone broad learning system (MBLS) and Copula theory. MBLS is a novel neural network structure for providing an efficient quantile regression solution. MBLS guarantees the monotonicity between quantiles and their probability for thoroughly avoiding the quantile crossing problem. The historical PV data are then clustered using the self-organizing map and samples in each cluster are used for Copula parameter estimations. The proposed approach provides an efficient spatio-temporal forecast of multiple PV plants by combining marginal distributions predicted by MBLS with Copula functions. The real-world data of PV plants in Australia and USA are used to the validate the superiority of the proposed method through detailed comparisons with existing methods using comprehensive evaluation criteria. The presented results demonstrate that the proposed method can provide high-quality probabilistic forecasts corresponding with PV power scenarios.
14 March 2023 in IEEE Transactions on Smart Grid
The proliferation of electric vehicles (EVs) and the increasing interdependence across power distribution networks (DNs) and transportation networks (TNs) have increased the complexity and vulnerability of the two systems in extreme circumstances. As the interdependence of two infrastructures tightens over time, it is viewed as a dire necessity to strengthen the resilience of the coordinated transportation-power distribution networks (TDNs) against natural disasters. This paper constructs a coordinated optimization method of TN traffic link reversing, DN line switching, and fast charging pile management, to improve the TDN performance in the emergency response stage after disasters. A dynamic TN model and a multi-period DN model are integrated in TDN modeling to capture flow propagations and state variations among time intervals. The coordinated optimization for TDN emergency response is designed as a mixed-integer nonlinear programming (MINLP) problem with high-order objective functions and nonlinear constraints to minimize TN travel costs and DN active and reactive power shortages. An accuracy-aware adaptive piecewise linearization approach combined with Gray code-based encoding is utilized to improve the computational efficiency for solving the TDN optimization problem. Numerical simulations show that the TDN performance is enhanced by coordinating various DN and TN resources, as compared with those of separate and conventional topology controls. The proposed TDN solution method has significantly reduced the computation time for managing extreme conditions while guaranteeing the accuracy of the results as compared with those of the nonlinear model and the linearized model by uniform piecewise linearization.
6 May 2020 in IEEE Transactions on Sustainable Energy
The uncertainties of single-phase integrated distributed energy resources (DERs) in the active distribution network (ADN) might lead to serious voltage unbalance (VU) problems. To cope with the corresponding VU problems, this paper proposes a two-stage uncertainty quantification and unbalance mitigation (UQUM) framework to quantify and mitigate the impacts of variable DERs on VU. In Stage one, the global sensitivity analysis based on the Rosenblatt transformation (RT-based GSA) method is proposed to quantify the impacts of correlated DERs with nonlinear correlation and tail dependence on VU. The RT-GSA method can identify the critical DERs which have significant impacts on VU. In Stage two, the joint allocation of fixed and mobile energy storage devices (ESDs) is proposed to compensate the uncertainties of critical DERs (identified in Stage one) for alleviating VU. The effectiveness of the proposed UQUM framework is verified in a 123-bus three-phase ADN system and the results are discussed.