Oleksandr V. Kyslov

Oleksandr V. Kyslov

Auto-generated profile, based on publicly available information

Oleksandr V. Kyslov

Kharkiv National Medical University, Kharkiv, Ukraine

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2026 in Clinical and Preventive Medicine
Verified
Journal Article
Open access
PDF file
OKOleksandr V. Kyslov
Oleksandr V. Kyslov
ONOksana A. Nakonechna
Oksana A. Nakonechna
LPLiudmyla D. Popova
Liudmyla D. Popova
SDSvitlana A. Denysenko
Svitlana A. Denysenko
IIIevgen G. Ivanov
Ievgen G. Ivanov
Introduction. Polypropylene implants are widely used in surgical practice; however, some authors point to numerous postoperative complications after their use, the main cause of which is the development of aseptic inflammation. This necessitates the search for effective anti-inflammatory coatings.Aim. To evaluate the influence of polypropylene implants coated with tantalum and its derivatives on inflammation and regeneration processes.Materials and methods. The study used 40 male rats, divided into 6 groups: intact (1); with surgical intervention without an implant (2); with an uncoated polypropylene implant (3); with a tantalum-coated implant (4); with a tantalum pentoxide-coated implant (5); with a tantalum nitride-coated implant (6). Morphological and immunohistochemical studies were performed.Results. In rats of groups 3 and 6, pronounced neutrophilic infiltration, purulent exudate, and a thin layer of immature granulation tissue were detected. Multinucleated foreign body giant cells were often observed in the granulation tissue. In rats of groups 4 and 5, neutrophilic infiltration was absent, granulation tissue was mature, and its layer thickness was one-third greater compared to groups 3 and 6. In rats of groups 4 and 5, a greater number of Ki-67 positive and a smaller number of p53 positive cells were detected, and a higher proliferative-apoptotic ratio (Ki-67/p53) was found compared to rats of groups 3 and 6.Conclusions. Polypropylene implant induces aseptic inflammation, leading to increased apoptosis and decreased regeneration. Coating the implant with tantalum or tantalum pentoxide prevents inflammation, reduces apoptosis, and increases cell proliferation. Coating the implant with tantalum nitride does not change it, while coating with tantalum or tantalum pentoxide improves its biointegration.

31 December 2023 in Experimental and Clinical Medicine
Verified
Journal Article
Open access
PDF file
ONO.A. Nakonechna
O.A. Nakonechna
OKO.V. Kyslov
O.V. Kyslov
For the past 10 years, specialists in hernioplasty have noted that there is a problem with the occurrence of an adhesion process after the implantation of surgical meshes. In the future, tantalum-based coatings may become an inhibitor of the development of adhesion and inflammatory processes after surgical mesh implantation. The aim of our study was to determine the state of the antioxidant system by the activity of superoxide dismutase 1 and catalase in the blood of rats after implantation of surgical meshes coated on the basis of tantalum, tantalum oxide and tantalum nitride. After acclimatization, which lasted 21 days, the experimental animals were divided into 6 groups by random sampling: the first (intact) group included 6 rats. The second group included 6 rats that underwent surgery, but without implementation of a surgical mesh. The third group included 7 rats with an implanted surgical mesh coated with tantalum. The fourth group included 7 rats with an implanted surgical mesh covered with tantalum oxide. The fifth group includes 7 rats with an implanted surgical mesh covered with tantalum nitride. The sixth group included 7 rats with an implanted surgical mesh without a coating. To achieve the goal, 40 laboratory rats were implanted with surgical meshes between the abdominal wall and various sections of the large intestine. After 28 days, the activity of SuperOxide Dismutase 1 (SOD 1) and catalase was determined in the blood of the animals. SOD 1 activity was statistically 126.3% higher, and catalase activity was 92.5% higher in the experimental group with surgical mesh without coating. SOD 1 activity was 126.6% higher and catalase activity was 100.0% higher in the experimental group with tantalum nitride coated surgical mesh. In the groups implanted with polypropylene surgical meshes coated with tantalum and tantalum oxide, the activity of SOD 1 was higher by 86.2% and 97.1%, respectively, and the activity of catalase was higher by 70.3% and 67.6%, respectively. As a result of the study, we came to the conclusion that coatings made of tantalum and tantalum oxide demonstrate high biocompatibility in comparison with the results of a group of experimental animals that were implanted with a surgical mesh without a coating. The use of tantalum and tantalum oxide coatings provides a protective effect of the implant against oxidative damage, which indicates their potential to improve the effectiveness of the use of surgical meshes. Keywords: tantalum oxide, superoxide dismutase 1, catalase.

30 August 2024 in Clinical and Preventive Medicine
Verified
Journal Article
Open access
PDF file
ONOksana A. Nakonechna
Oksana A. Nakonechna
OKOleksandr V. Kyslov
Oleksandr V. Kyslov
IKIhor A. Kulyk
Ihor A. Kulyk
ІКІгор А. Кулик
Ігор А. Кулик
Aim. To investigate the viability and types of cell death of peripheral blood leukocytes in experimental animals after implantation of surgical meshes with a tantalum-based coating and its derivatives. Materials and methods. The experimental group included 40 male rats of the WAG population. Polypropylene surgical mesh was surgically implanted between the abdominal wall and sections of the large intestine with different types of coatings. After 28 days, collected blood was analyzed by a BD FACSCanto™ II flow cytometer. Results. It was determined that there were no significant changes in the viability of blood leukocytes between the animals of the intact group and the group of animals that underwent surgery without implantation. Analysis of leukocyte viability in groups of rats implanted with tantalum and tantalum oxide-coated meshes showed a slight decrease in viable cells compared with the results of the intact group. At the same time, the percentage of necrotic cells showed a slight increase. In the group of rats implanted with a mesh with tantalum nitride-coated, a decrease in viable leukocytes was determined in comparison with the results of the intact group by 12,9%, while the percentage of necrotic leukocytes was 3,8% higher. A 16,2% decrease in viable leukocytes was determined in the group of rats implanted with a non-coated mesh compared to the results of the intact group. At the same time, the percentage of necrotic cells was 6,9% higher. Conclusions. Implantation of uncoated and tantalum nitride-coated surgical meshes was found to decrease the percentage of viable blood leukocytes in rats compared to intact animals, while implantation of tantalum- and tantalum-oxide-coated surgical meshes did not significantly decrease viable white blood cells. leukocytes.