30 April 2019 in Brazilian Dental Science
Objective: Despite the higher translucency of nano-crystalline Y-TZP than the conventional Y-TZP, it couldn’t be used in the anterior region of the mouth in its fully anatomical form without veneering for better esthetics. This study evaluated the color change (?E) and translucency parameter (TP) of the bilayered nano-crystalline zirconia restorations after different treatments of the zirconia surface before and after accelerated aging. Material and Methods: Forty samples of inCoris TZI were cut in the form of discs 15 mm (diameter) and 1mm (thickness) so that after sintering each disc dimensions’ would be 12 mm (diameter) and 0.8 mm (thickness). All discs were colored by dipping in aqueous zirconia coloring solution of shade A2, then divided into four groups according to the type of surface treatment received before sintering; being tribochemical silica coating, zirconia powder deposition, glass grading, and a control untreated group. After sintering, all discs were veneered with a layer of porcelain 0.7 mm (thickness) and 12 mm (diameter). (?E) and TP were measured using VITA Easyshade Compact spectrophotometer before and after accelerated autoclave aging. Results: Different surface treatments applied had significant effect (P<0.05) over ?E and TP. Glass graded group showed the highest ?E value and the least TP value among both un-aged and aged sub-groups. Conclusion: Different surface treatments applied affected the color and translucency negatively where the control untreated group showed the highest TP and the least color deviation from the A2 color parameters. On the other hand, accelerated autoclave aging had no effect over translucency or color.KeywordsAging; Ceramic restoration; Color; Translucent.
1 July 2019 in Egyptian Dental Journal
Statement of problem: With the advancement of digital technology, extraoral digital scanners have become popular among dental laboratories and dentists. The literature concerning accuracy of restorations fabricated from digital images of extraoral scanners is non conclusive.Aim: The the aim of the study is to compare the accuracy of single crowns generated from CAD/CAM Systems using digital images of two extra-oral scanners. Materials and Methods: Twenty 3D printed dies were scanned using the investigated extraoral scanners (InEos X5 and Ceramill map 400). The digital images were used to produce a 3D virtual crown design on the systems’ respective CAD softwares. Crowns were milled of lithium disilicate blocks. The milled crowns were divided into two groups according to the type of CAD/CAM system used; Group I/M (Cerec system: In Eos X5 and MCX5) and Group C/C (Amanngirbach System: Ceramill map 400 and Ceramill motion2), 10 crowns each. The marginal gap distance between the crown and the 3D printed resin die was measured using a digital microscope and replica technique was used to measure the internal gap between the crowns and their respective 3D printed resin dies. Results: Group I/M demonstrated statistically significant smaller median marginal gap distance 95 μm while Group C/C demonstrated a median marginal gap distance of 113 μm. The was no statistically significant difference between both systems with regards to internal fitness. The accuracy of crowns of both systems was within clinically acceptable range.Conclusions: Crowns generated from CEREC system (In Eos X5/ MCX5) showed better marginal accuracy than AmannGirrbach system. (Ceramill map 400 / Ceramill motion 2). Both systems produced marginal accuracy and internal fitness within the clinically accepted range.