Florent Gauthier

Florent Gauthier

Auto-generated profile, based on publicly available information

Florent Gauthier

ITER Organization, St. Paul-lez-Durance, France

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 January 2016 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
NMNicolai Martovetsky
Nicolai Martovetsky
TITakaaki Isono
Takaaki Isono
DBDenis Bessette
Denis Bessette
YTYoshikazu Takahashi
Yoshikazu Takahashi
YNYoshihiko Nunoya
Yoshihiko Nunoya
JDJean-Luc Duchateau
Jean-Luc Duchateau
The ITER central solenoid (CS) is a highly stressed magnet that must provide 30 000 plasma cycles under the ITER prescribed maximum operating conditions. To verify the performance of the ITER CS conductor in conditions close to those for the ITER CS, the CS insert was built under a USA-Japan collaboration. The insert was tested in the aperture of the CSMC facility in Naka, Japan, during the first half of 2015. A magnetic field of up to 13 T and a transport current of up to 60 kA provided a wide range of parameters to characterize the conductor. The CS insert has been tested under direct and reverse charges, which allowed a wide range of strain variation and provided valuable data for characterization of the CS conductor performance at different strain levels. The CS insert test program had several important goals as follows. 1) Measure the temperature margin of the CS conductor at the relevant ITER CS operational conditions. 2) Study the effects of electromagnetic forces and strain in the cable on the CS conductor performance. 3) Study the effects of the warmup and cooldown cycles on the CS conductor performance. 4) Compare the conductor performance in the CS insert with the performance of the CS conductor in a straight hairpin configuration (hoop strain free) tested in the SULTAN facility. 5) Measure the maximum temperature rise of the cable as a result of quench. The main results of the CS insert testing are presented and discussed.

8 March 2022 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
PBP. Bauer
P. Bauer
MBMarco Breschi
Marco Breschi
LCLorenzo Cavallucci
Lorenzo Cavallucci
JDJ. L. Duchateau
J. L. Duchateau
FGF. Gauthier
F. Gauthier
BTB. Turck
B. Turck
AC loss is a major heat load in the pulsed, superconducting ITER coils, and thus a design driver for the cryo-system and superconductor. Given the importance of AC loss, extensive AC loss characterization of the components of the ITER coils, from the superconducting strands, cables, long “coil-like” conductors (so called insert-coils) to the completed coils, were conducted over the past years. Recently the first Central Solenoid (CS) modules were factory tested including AC loss tests representative of the operational conditions. The modelling of the AC loss is critical for the preparation of ITER Tokamak operation and commissioning. The following describes the AC loss models for the ITER CS coils. Such models need to be simple to implement and fast to execute to allow simulation of the long ITER plasma scenarios. The paper explains the simplifications applied and discusses the implications. The status of the validations of the model on experimental data are presented.

24 February 2021 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
MBMarco Breschi
Marco Breschi
LCLorenzo Cavallucci
Lorenzo Cavallucci
PRPier Luigi Ribani
Pier Luigi Ribani
RBRoberto Bonifetto
Roberto Bonifetto
AZAndrea Zappatore
Andrea Zappatore
NMNicolai Martovetsky
Nicolai Martovetsky
The ITER Central Solenoid (CS) will be manufactured by assembling a stack of six modules, which are under fabrication by the US ITER organization and its subcontractors. The tests of the first CS Module have been performed at the premises of the General Atomics (GA) facility in Poway (US), in order to check compliance to the ITER requirements. Among other tests, the magnet was submitted to exponential dumps of the transport current from different initial values (10, 15, 20, 22.5, 25, 35, 40 kA) down to 0 kA. These tests are aimed at conducting DC breaker commissioning of the test facility and were used to measure the AC losses in the coil during electrodynamic transients. This paper presents the results of these measurements, along with a comparison with analytical computations of the losses in the magnet.

27 March 2023 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Open access
PBPierre Bauer
Pierre Bauer
MBMarco Breschi
Marco Breschi
LCLorenzo Cavallucci
Lorenzo Cavallucci
JDJean-Luc Duchateau
Jean-Luc Duchateau
FGFlorent Gauthier
Florent Gauthier
BTBernard Turck
Bernard Turck
While the ITER magnet system assembly is progressing, models are being developed to predict the performances of the coils in support of the preparation of commissioning and operation. In particular, the AC losses generated in the coils during a plasma scenario need to be estimated as input to thermo-hydraulic performance simulations. The largest AC losses during plasma operation are expected in the CS and PF coils. This paper discusses the results of simulations of AC losses in these coils during a representative ITER plasma pulse. These calculations also take into account the electromagnetic screening provided by the ITER passive structures, most importantly the vacuum vessel, discussing its impact on the conductor AC losses. The results will also be compared to earlier predictions. Finally, the CS and PF coil AC losses expected during commissioning will be briefly discussed.

14 February 2022 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
ATA. Torre
A. Torre
PBP. Bauer
P. Bauer
JDJ. L. Duchateau
J. L. Duchateau
FGF. Gauthier
F. Gauthier
BTB. Turck
B. Turck
During the years of ITER conductors qualification and production, samples from all domestic agencies were tested. Some of these tests were focused on characterizing the AC losses properties of the ITER conductors. The data produced originate from various facilities (PSI, University of Twente, CERN), using different experimental and data reduction protocols, for a large number of samples. The result is thus a considerable database of results with a wide spread in the properties. The need for a reduced set of parameters describing the AC losses properties of the ITER conductors is now becoming urgent in order to permit consistent analysis of the coils heat loads in commissioning and operation. In particular, PF and CS are pulsed coils, cooled by supercritical helium 4.5 K, operating at nominal currents up to 50 kA while subject to time varying fields that can reach 2 T/s during the plasma scenario. This paper summarizes the reference conductor samples, the models and the parameters that emerge from the extensive experimental characterizations, hoping to give a strong baseline for analysts investigating AC losses in ITER CS and PF conductors.

7 February 2022 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
MBMarco Breschi
Marco Breschi
LCLorenzo Cavallucci
Lorenzo Cavallucci
PBP. Bauer
P. Bauer
FGF. Gauthier
F. Gauthier
RBRoberto Bonifetto
Roberto Bonifetto
JSJ. Sheeron
J. Sheeron
The ITER Central Solenoid (CS) will be realized by assembling a stack of six modules. Each module is a solenoid consisting of 40 pancakes wound with a Nb 3 Sn Cable in Conduit Conductor (CICC). The tests of the second module (CSM#2) were performed at the General Atomics (GA) facility in Poway (US). During the test campaign, the CS Module is submitted to dumps of the transport current from different initial values (10, 15, 20, 25, 30, 35, 40 kA) to 0 kA, which allow measuring the AC losses in the coil. In this paper we present the results on AC losses during the dumps from different initial transport currents, as computed with two different methods. The first method is based on the observation that the dumps determine a very fast pressure rise of the supercritical helium embedded in the module, which undergoes an isochoric transformation. This approach is therefore based on the computation of the variation of internal energy of the helium during the pressure rise itself. The second method is based instead on a calorimetric procedure aimed at estimating the enthalpy variation of the supercritical helium due to the thermal power deposited during the current dumps. The main contribution to the losses during these dumps is due to the coupling losses. As for the hysteresis losses in the magnet, the results obtained through slow current cycle tests are also presented.