Herve Tortel

Herve Tortel

Auto-generated profile, based on publicly available information

Herve Tortel

Aix-Marseille Université, CNRS, Ecole Centrale Marseille, Institut Fresnel, 13013 Marseille, France

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 1999 in Journal of Electromagnetic Waves and Applications
Verified
Journal Article
Closed access
HTH. Tortel
H. Tortel
GMG. Micolau
G. Micolau
MSM. Saillard
M. Saillard
The method of decomposition of the time reversal operator has been introduced with the aim of focusing acoustic waves on a selected target. It is based on the derivation of the invariants of the ti...

14 October 2014 in IEEE Antennas and Wireless Propagation Letters
Verified
Journal Article
Open access
CEC. Eyraud
C. Eyraud
JGJ.-M. Geffrin
J.-M. Geffrin
ALA. Litman
A. Litman
HTH. Tortel
H. Tortel
An accurate knowledge of the complex permittivity value of materials is compulsory when performing experimental electromagnetic applications. Unfortunately, these values are not so obvious to determine in practice. In this letter, we propose a novel approach for determining the complex dielectric constant of materials. This method combines free-space far-field scattering pattern measurements with a Bayesian procedure, which fully exploits the measurement uncertainties. Therefore, the measured values weighted according to their experimental accuracy are incorporated in the permittivity determination algorithm. In this letter, the samples are all shaped as spheres in order to benefit from efficient Mie scattered field computations. The dielectric properties of typical plastic samples are first determined and compared to values found in the literature in order to assess the validity and the accuracy of the proposed methodology. A more “exotic” sample extracted from a microwave absorber, which is a polyurethane foam charged with carbon particles, is also analyzed.

9 November 2010 in IEEE Geoscience and Remote Sensing Letters
Verified
Journal Article
Closed access
XZX. Zhang
X. Zhang
HTH. Tortel
H. Tortel
SRS. Ruy
S. Ruy
ALA. Litman
A. Litman
This letter deals with the monitoring of the volumetric water content of a soil column in a fully controlled environment by means of a noninvasive microwave imaging system. Indeed, soil moisture is an important piece of information to improve fluid flow modeling or to better understand the water uptake by plant roots. In this letter, we address the problem of recovering the footprint of soil moisture evolution with respect to time using a built-in laboratory microwave setup coupled to a robust qualitative microwave imaging method: the linear sampling method (LSM). The evolution of the water content in the soil is ruled by the Richards equations and stored at different time steps. The associated maps of soil water content are converted into permittivity maps using the Dobson model. Electromagnetic scattered fields are then computed with finite-element software. We have tested the LSM in a situation that can be encountered in agricultural soils where the water content is not homogeneous. We show that the evolution of the soil water content can be qualitatively monitored with the LSM. We also point out that the source is more precisely located by considering the evolution in time of the singular system of the multistatic matrix (multiple signal classification method).

3 February 2009 in Inverse Problems
Verified
Journal Article
Closed access
RLR Lencrerot
R Lencrerot
ALA Litman
A Litman
HTH Tortel
H Tortel
JGJ-M Geffrin
J-M Geffrin

1 January 2010 in Progress In Electromagnetics Research
Verified
Journal Article
Closed access
PDF file
ALAmelie Litman
Amelie Litman
JGJean-Michel Geffrin
Jean-Michel Geffrin
HTHerve Tortel
Herve Tortel
International audienceThe calibration of the multistatic scattering matrix plays an important part in the construction of a quantitative microwave imaging system. For scattering measurement applications, the calibration must be performed on the amplitude and on the phase of the fields of interest. When the antennas are not completely identical, as for example with a multiplexed antennas array, a specific calibration procedure must be constructed. In the present work, we explain how a complex calibration matrix can be defined which takes advantage of the geometrical organization of the antennas. Indeed, for arrays of antennas positioned on a circle, the inherent symmetries of the configuration can be fully exploited by means of an adequate reorganization of the multistatic scattering matrix. In addition, the reorganization permits to detect antenna pairs which are not properly functioning and to estimate the signal-to-noise ratio. Experimental results obtained within a cylindrical cavity enclosed by a metallic casing are provided to assess the performance of the proposed calibration procedure.This calibration protocol, which is described here in detail, has already been applied to provide quantitative images of dielectric targets [1, 2]

1 September 2021 in Journal of Quantitative Spectroscopy and Radiative Transfer
Verified
Journal Article
Closed access
JRJean-Baptiste Renard
Jean-Baptiste Renard
JGJean-Michel Geffrin
Jean-Michel Geffrin
VVVanesa Tobon Valencia
Vanesa Tobon Valencia
HTHervé Tortel
Hervé Tortel
FMFrancois MENARD
Francois MENARD
GBGwenaël Berthet
Gwenaël Berthet