Petr Balling

Petr Balling

Auto-generated profile, based on publicly available information

Petr Balling

Czech Metrology Institute, Okružní 31, 638 00 Brno, Czech Republic

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 May 2009 in Optics Express
Verified
Journal Article
Closed access
PDF file
PBPetr Balling
Petr Balling
PKPetr Křen
Petr Křen
PMPavel Mašika
Pavel Mašika
SBS.A. van Den Berg
S.A. van Den Berg
Interferometric measurement of distance using a femtosecond frequency comb is demonstrated and compared with a counting interferometer displacement measurement. A numerical model of pulse propagation in air is developed and the results are compared with experimental data for short distances. The relative agreement for distance measurement in known laboratory conditions is better than 10-7. According to the model, similar precision seems feasible even for long-distance measurement in air if conditions are sufficiently known. It is demonstrated that the relative width of the interferogram envelope even decreases with the measured length, and a fringe contrast higher than 90% could be obtained for kilometer distances in air, if optimal spectral width for that length and wavelength is used. The possibility of comb radiation delivery to the interferometer by an optical fiber is shown by model and experiment, which is important from a practical point of view.

23 May 2012 in Metrologia
Verified
Journal Article
Closed access
MPMarco Pisani
Marco Pisani
AYAndrew Yacoot
Andrew Yacoot
PBPetr Balling
Petr Balling
NBNicola Bancone
Nicola Bancone
CBCengiz Birlikseven
Cengiz Birlikseven
CWChristoph Weichert
Christoph Weichert

12 November 2015 in Metrologia
Verified
Journal Article
Closed access
PDF file
MDM Doležal
M Doležal
PBP Balling
P Balling
PNP B R Nisbet-Jones
P B R Nisbet-Jones
SKS A King
S A King
JJJ M Jones
J M Jones
EPE Peik
E Peik
In many of the high-precision optical frequency standards with trapped atoms or ions that are under development to date, the ac Stark shift induced by thermal radiation leads to a major contribution to the systematic uncertainty. We present an analysis of the inhomogeneous thermal environment experienced by ions in various types of ion traps. Finite element models which allow the determination of the temperature of the trap structure and the temperature of the radiation were developed for five ion trap designs, including operational traps at PTB and NPL and further optimized designs. Models were refined based on comparison with infrared camera measurement until an agreement of better than 10% of the measured temperature rise at critical test points was reached. The effective temperature rises of the radiation seen by the ion range from 0.8 K to 2.1 K at standard working conditions. The corresponding fractional frequency shift uncertainties resulting from the uncertainty in temperature are in the 10 −18 range for optical clocks based on the Sr + and Yb + E2 transitions, and even lower for Yb + E3, In + and Al + . Issues critical for heating of the trap structure and its predictability were identified and design recommendations developed.

25 July 2012 in Measurement Science and Technology
Verified
Journal Article
Closed access
PBPetr Balling
Petr Balling
PMPavel Mašika
Pavel Mašika
PKPetr Křen
Petr Křen
MDMiroslav Doležal
Miroslav Doležal

1 January 2005 in Optics Express
Verified
Journal Article
Closed access
PDF file
PBPetr Balling
Petr Balling
MFMarc Fischer
Marc Fischer
PKPhilipp Kubina
Philipp Kubina
RHRonald Holzwarth
Ronald Holzwarth
The frequency of a wavelength standard at 1542 nm (194 THz) developed in CMI for the telecommunication band C was measured with a fiber femtosecond frequency comb. The measurement was done for three transitions of acetylene 13C2H2: P(14), P(15) and P(16). The results agree well with values in the recommendation for Practical realization of the definition of the metre [1] and even better with recent measurements made in NMIJ/AIST [2,3] - the differences are lower than 2 kHz (or 1×10-11 rel.) for all three transitions. This agreement is significant considering the fact that the CMI laser uses an extremely simple spectroscopic arrangement and substantially lower saturation power.

11 March 2016 in Applied Physics B
Verified
Journal Article
Closed access
PDF file
PNP. B. R. Nisbet-Jones
P. B. R. Nisbet-Jones
SKS. A. King
S. A. King
JJJ. M. Jones
J. M. Jones
RGR. M. Godun
R. M. Godun
CBC. F. A. Baynham
C. F. A. Baynham
PGP. Gill
P. Gill