Atul Kumar Mishra

Atul Kumar Mishra

Auto-generated profile, based on publicly available information

Atul Kumar Mishra

Department of Computer Science and Engineering, RV College of Engineering, Bengaluru, India

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2026 in IEEE Access
Verified
Journal Article
Open access
NHNishant Vasantkumar Hegde
Nishant Vasantkumar Hegde
SGSaksham Gupta
Saksham Gupta
AMAtul Kumar Mishra
Atul Kumar Mishra
DPD Pratiba
D Pratiba
PKP. Ramakanth Kumar
P. Ramakanth Kumar
TST. Shankar
T. Shankar
Manual monitoring of intravenous (IV) therapy is labor-intensive and susceptible to human error, posing risks to patient safety. Existing computer vision-based approaches have addressed either drip rate estimation or fluid level monitoring in isolation, limiting their clinical applicability. This work presents and validates a dual-module computer vision framework for a practical, automated IV monitoring system that simultaneously addresses both tasks. For the critical task of drip rate estimation, we conduct a comparative study of two distinct deep learning paradigms on a diverse custom dataset of 3,458 images, evaluated on a strictly held-out test set: a state-of-the-art YOLOv8 object detector, achieving mAP0.50 of 95.34%, and a novel heatmap-based point-event regression network (ResNet-18 encoder with convolutional decoder), achieving a frame-wise accuracy of 88.44% and recall of 95.16%. The second module leverages a bespoke convolutional neural network (CNN) for fluid level classification, reaching a test accuracy of 95.26% on a public benchmark dataset. Finally, we demonstrate a proof-of-concept prototype that successfully integrates both modules into a unified, automated video-based application, validated on pre-recorded clinical video footage. End-to-end counting evaluation on a 7-video set spanning drip rates from 17 to 94 dpm shows the heatmap-based counter achieves 91.0% mean counting accuracy versus 77.5% for the YOLOv8-based counter, with the heatmap demonstrating markedly greater robustness at elevated infusion rates. By validating high-performance solutions for both monitoring tasks and demonstrating a clear path to integration, this study establishes a comprehensive framework for a holistic IV infusion monitoring system with the potential to enhance patient safety and reduce the burden on clinical staff.