Stefano Barsali

Stefano Barsali

Auto-generated profile, based on publicly available information

Stefano Barsali

DESTEC - University of Pisa, Pisa, Italy

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 August 2002 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
SBS. Barsali
S. Barsali
MCM. Ceraolo
M. Ceraolo
This paper explains how the lead-acid models described in a previous paper (see M. Ceraolo, IEEE Trans. Power Syst., vol.15, p.1184-90, 2000) can be utilized in practice. Two main issues are opened by that paper: (1) the paper does not supply detailed information on how to identify the several parameters of the proposed models, and (2) it defines a whole family of models, but does not discuss which model of the family is adequate for a given purpose. These two issues are tackled in this paper. For the first issue, the more complex one, two options are proposed and discussed: (1) a complete identification procedure involving extensive lab tests, and (2) a simplified one that combines information from lab tests and data, supplied by the manufacturer. In addition, further simplifications applicable in cases of batteries belonging to the same family are presented.

25 June 2003
Verified
Conference Paper
Closed access
SBS. Barsali
S. Barsali
MCM. Ceraolo
M. Ceraolo
PPP. Pelacchi
P. Pelacchi
DPD. Poli
D. Poli
It is expected that dispersed generation (DG) will play an increasing role in electric power systems in the near future. Among the benefits that DG can give to the power system operators and to the electricity customers, one of the most attractive is the possibility of improving the continuity of power supply. DG plants can be designed to supply portions of the distribution grid in the event of an upstream supply outage. Techniques for controlling DG plants that use feedback of only locally measurable variables are presented. This solution allows correct system operation and switching between parallel and isolated modes without needing online communication of control signals between the generators. The control technique is described with particular reference to inverter-interfaced systems (micro-turbines, fuel cells). Simulations of sample cases including different size and type of generators are presented.

26 February 2004 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
SBS. Barsali
S. Barsali
CMC. Miulli
C. Miulli
APA. Possenti
A. Possenti
This paper presents an approach to the problem of controlling the electricity generation of series hybrid electric vehicles (SHEVs) and proposes an algorithm with the goal to minimize fuel consumption. Starting from the knowledge of the vehicle electric generator consumption maps, as well as information on the vehicle battery behavior, and on some overall parameters characterizing the expected trip, the algorithm is able to define: whether to continuously keep the generator in the ON state or not; when to, if is the case, switch the generator ON or OFF; the instantaneous power to be delivered by the electric generator when in ON state. Adopting such parameters enables avoiding to previously know the battery losses on a given trip and offers the possibility to update the control according to online measures. Addresses are also given on how to online assess the trip parameters to be used as inputs for the algorithm.

1 May 2017 in Applied Energy
Verified
Journal Article
Closed access
MAMarco Antonelli
Marco Antonelli
SBStefano Barsali
Stefano Barsali
Umberto DesideriUmberto Desideri
Umberto Desideri
RGRomano Giglioli
Romano Giglioli
FPFabrizio Paganucci
Fabrizio Paganucci
GPGianluca Pasini
Gianluca Pasini

7 August 2002 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
SBS. Barsali
S. Barsali
MCM. Ceraolo
M. Ceraolo
APA. Possenti
A. Possenti
In a series hybrid electric vehicle (SHEV), an electric generator feeds a DC busbar (containing an electrochemical accumulator), which, in turns, feeds the vehicle traction system. A very important part of the vehicle is its control system, which has to maximize the vehicle efficiency while keeping the emissions within predetermined limits. To attain this goal, it can act in two ways: (1) it can switch the electric generator ON or OFF, and (2) when in the ON state, it can impose a given power to be delivered. To choose the control actions to perform it needs (a) an algorithm to understand the behavior of the battery (determine the state-of-charge, maximum power, losses) and (b) an algorithm to make some forecast of the system load (i.e., the power required in the future of the trip, as a function of time). This paper discusses the main problems that arise when trying to synthesize the control system of the vehicle, taking into account issues (a) and (b). Some lab tests are also presented in which some of the proposed control techniques are experimentally checked.

1 August 2015 in Renewable Energy
Verified
Journal Article
Closed access
SBS. Barsali
S. Barsali
AMA. De Marco
A. De Marco
RGR. Giglioli
R. Giglioli
GLG. Ludovici
G. Ludovici
APA. Possenti
A. Possenti