James L. Robar

James L. Robar

Auto-generated profile, based on publicly available information

James L. Robar

Department of Physics and Atmospheric Science, Dalhousie University, 5820 University Avenue, Halifax, Nova Scotia, B3H 1V7, Canada

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2018 in Practical Radiation Oncology
Verified
Journal Article
Open access
JRJames L. Robar
James L. Robar
KMKathryn Moran
Kathryn Moran
JAJames Allan
James Allan
JCJames Clancey
James Clancey
TJTami Joseph
Tami Joseph
RRRobert Rutledge
Robert Rutledge
This patient study evaluated the use of 3-dimensional (3D) printed bolus for chest wall radiation therapy compared with standard sheet bolus with regard to accuracy of fit, surface dose measured in vivo, and efficiency of patient setup. By alternating bolus type over the course of therapy, each patient served as her own control. For 16 patients undergoing chest wall radiation therapy, a custom 5.0 mm thick bolus was designed based on the treatment planning computed tomography scan and 3D printed using polylactic acid. Cone beam computed tomography scanning was used to image and quantify the accuracy of fit of the 2 bolus types with regard to air gaps between the bolus and skin. As a quality assurance measure for the 3D printed bolus, optically stimulated luminescent dosimetry provided in vivo comparison of surface dose at 7 points on the chest wall. Durations of patient setup and image guidance were recorded and compared. In 13 of 16 patients, the bolus was printed without user intervention, and the median print time was 12.6 hours. The accuracy of fit of the bolus to the chest wall was improved significantly relative to standard sheet bolus, with the frequency of air gaps 5 mm or greater reduced from 30% to 13% (P < .001) and maximum air gap dimension diminished from 0.5 ± 0.3 to 0.3 ± 0.3 mm on average. Surface dose was within 3% for both standard sheet and 3D printed bolus. On average, the use of 3D printed bolus reduced the setup time from 104 to 76 seconds. This study demonstrates 3D printed bolus in postmastectomy radiation therapy improves fit of the bolus and reduces patient setup time marginally compared with standard vinyl gel sheet bolus. The time savings on patient setup must be weighed against the considerable time needed for the 3D printing process.


2 September 2022 in Journal of Applied Clinical Medical Physics
Verified
Journal Article
Open access
JRJames L. Robar
James L. Robar
BKBarret Kammerzell
Barret Kammerzell
KHKevin Hulick
Kevin Hulick
PKPierre Kaiser
Pierre Kaiser
CYCalvin Young
Calvin Young
JSJames Stasiak
James Stasiak
Purpose: Thermoplastic immobilizers are used routinely in radiation therapy to achieve positioning accuracy. These devices are variable in quality as they are dependent on the skill of the human fabricator. We examine the potential multi jet fusion (MJF) 3D printing for the production immobilizers with a focus on the surface dosimetry of several MJF‐printed PA12‐based material candidates. Materials are compared with the goal of minimizing surface dose with comparison to standard thermoplastic. We introduce a novel metamaterial design for the shell of the immobilizer, with the aims of mechanical robustness and low‐dose buildup. We demonstrate first examples of adult and pediatric cranial and head‐and‐neck immobilizers.Methods: Three different PA12 materials were examined and compared to fused deposition modeling–printed polylactic acid (PLA), PLA with density lowered by adding hollow glass microspheres, and to perforated or perforated/stretched and solid status quo thermoplastic samples. Build‐up dose measurements were made using a parallel plate chamber. A metamaterial design was established based on a packed hexagonal geometry. Radiochromic film dosimetry was performed to determine the dependence of surface dose on the metamaterial design. Full cranial and head‐and‐neck prototype immobilizers were designed, printed, and assessed with regard to dimensional accuracy.Results: Build‐up dose measurements demonstrated the superiority of the PA12 material with a light fusing agent, which yielded a ∼15% dose reduction compared to other MJF materials. Metamaterial samples provided dose reductions ranging from 11% to 40% compared to stretched thermoplastic. MJF‐printed immobilizers were produced reliably, demonstrated the versatility of digital design, and showed dimensional accuracy with 97% of sampled points within ±2 mm.Conclusions: MJF is a promising technology for an automated fabrication of patient immobilizers. Material selection and metamaterial design can be leveraged to yield surface dose reduction of up to 40%. Immobilizer design is highly customizable, and the first examples of MJF‐printed immobilizers demonstrate excellent dimensional accuracy.

22 March 2016 in Medical Physics
Verified
Journal Article
Closed access
DPDavid Donald Mortimer Parsons
David Donald Mortimer Parsons
JRJames L. Robar
James L. Robar

22 February 2023 in Biomedical Physics & Engineering Express
Verified
Journal Article
Closed access
PSP Sadeghi
P Sadeghi
DBD Bastin-Decoste
D Bastin-Decoste
JRJ L Robar
J L Robar
The purpose of this work is to introduce and evaluate a capacitive monitoring array capable of continuous 6DOF cranial motion detection during high precision radiotherapy. The ring-shaped capacitive array consists of four equally sized conductive sensors positioned at the cranial vertex. The system is modular, non-contact, and provides continuous motion information through the thermoplastic immobilization mask without relying on skin monitoring or use of ionizing radiation. The array performance was evaluated through a volunteer study with a cohort of twenty-five individuals. The study was conducted in a linac suite and the volunteers were fitted with an S-frame thermoplastic mask. Each volunteer took part in one data acquisition session per day for three consecutive days. During the data acquisition, the conductive array was translated and rotated relative to their immobilized cranium in 1-millimetre and 1-degree steps to simulate cranial motion. Capacitive signals were collected at each position at a frequency of 20 Hz. The data from the first acquisition session was then used to train a classifier model and establish calibration equations. The classifier and calibration equations were then applied to data from the subsequent acquisition sessions to evaluate the system performance. The trained classifiers had an average success rate of 92.6% over the volunteer cohort. The average error associated with calibration had a mean value below 0.1 mm or 0.1 deg for all six motions. The capacitive array system provides a novel method to detect translational and rotational cranial motion through a thermoplastic mask.