Mohammad Hassan Jahanandish

Mohammad Hassan Jahanandish

Auto-generated profile, based on publicly available information

Mohammad Hassan Jahanandish

Department of Urology, Stanford University School of Medicine, Stanford, CA 94305, USA

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2019 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
MJMohammad Hassan Jahanandish
Mohammad Hassan Jahanandish
NFNicholas Fey
Nicholas Fey
KHKenneth Hoyt
Kenneth Hoyt
Objective: Powered assistive devices need improved control intuitiveness to enhance their clinical adoption. Therefore, the intent of individuals should be identified and the device movement should adhere to it. Skeletal muscles contract synergistically to produce defined lower-limb movements so unique contraction patterns in lower-extremity musculature may provide a means of device joint control. Ultrasound (US) imaging enables direct measurement of the local deformation of muscle segments. Hence, the objective of this study was to assess the feasibility of using US to estimate human lower-limb movements. Methods: A novel algorithm was developed to calculate US features of the rectus femoris muscle during a non-weight-bearing knee flexion/extension experiment by 9 able-bodied subjects. Five US features of the skeletal muscle tissue were studied, namely, thickness, angle between aponeuroses, pennation angle, fascicle length, and echogenicity. A multiscale ridge filter was utilized to extract the structures in the image and a random sample consensus (RANSAC) model was used to segment muscle aponeuroses and fascicles. A localization scheme further guided RANSAC to enable tracking in an US image sequence. Gaussian process regression (GPR) models were trained using segmented features to estimate both knee joint angle and angular velocity. Results: The proposed segmentation-estimation approach could estimate knee joint angle and angular velocity with an average root mean square error value of 7.45 degrees and 0.262 rad/s, respectively. The average processing rate was 3-6 frames per second that is promising towards real-time implementation. Conclusion: Experimental results demonstrate the feasibility of using US to estimate human lower-extremity motion. The ability of algorithm to work in real-time may enable the use of US as a neural interface for lower-limb applications. Significance: Intuitive intent recognition of human lower-extremity movements using wearable US imaging, may enable volitional assistive device control, and enhance locomotor outcomes for those with mobility impairments.

21 October 2020 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
KRKaitlin G. Rabe
Kaitlin G. Rabe
MJMohammad Hassan Jahanandish
Mohammad Hassan Jahanandish
JBJacob R. Boehm
Jacob R. Boehm
AFAnn Majewicz Fey
Ann Majewicz Fey
KHKenneth Hoyt
Kenneth Hoyt
NFNicholas Fey
Nicholas Fey
Clinical translation of “intelligent” lower-limb assistive technologies relies on robust control interfaces capable of accurately detecting user intent. To date, mechanical sensors and surface electromyography (EMG) have been the primary sensing modalities used to classify ambulation. Ultrasound (US) imaging can be used to detect user-intent by characterizing structural changes of muscle. Our study evaluates wearable US imaging as a new sensing modality for continuous classification of five discrete ambulation modes: level, incline, decline, stair ascent, and stair descent ambulation, and benchmarks performance relative to EMG sensing. Ten able-bodied subjects were equipped with a wearable US scanner and eight unilateral EMG sensors. Time-intensity features were recorded from US images of three thigh muscles. Features from sliding windows of EMG signals were analyzed in two configurations: one including 5 EMG sensors on muscles around the thigh, and another with 3 additional sensors placed on the shank. Linear discriminate analysis was implemented to continuously classify these phase-dependent features of each sensing modality as one of five ambulation modes. US-based sensing statistically improved mean classification accuracy to 99.8% (99.5-100% CI) compared to 8-EMG sensors (85.8%; 84.0-87.6% CI) and 5-EMG sensors (75.3%; 74.5-76.1% CI). Further, separability analyses show the importance of superficial and deep US information for stair classification relative to other modes. These results are the first to demonstrate the ability of US-based sensing to classify discrete ambulation modes, highlighting the potential for improved assistive device control using less widespread, less superficial and higher resolution sensing of skeletal muscle.

22 July 2016 in Assistive Technology
Verified
Journal Article
Closed access
STSajjad Taghvaei
Sajjad Taghvaei
MJMohammad Hasan Jahanandish
Mohammad Hasan Jahanandish
KKKazuhiro Kosuge
Kazuhiro Kosuge
Population aging of the societies requires providing the elderly with safe and dependable assistive technologies in daily life activities. Improving the fall detection algorithms can play a major role in achieving this goal. This article proposes a real-time fall prediction algorithm based on the acquired visual data of a user with walking assistive system from a depth sensor. In the lack of a coupled dynamic model of the human and the assistive walker a hybrid “system identification-machine learning” approach is used. An autoregressive-moving-average (ARMA) model is fitted on the time-series walking data to forecast the upcoming states, and a hidden Markov model (HMM) based classifier is built on the top of the ARMA model to predict falling in the upcoming time frames. The performance of the algorithm is evaluated through experiments with four subjects including an experienced physiotherapist while using a walker robot in five different falling scenarios; namely, fall forward, fall down, fall back, fall left, and fall right. The algorithm successfully predicts the fall with a rate of 84.72%.

5 February 2025 in Medical Image Analysis
Verified
Journal Article
Closed access
CLCynthia Xinran Li
Cynthia Xinran Li
IBIndrani Bhattacharya
Indrani Bhattacharya
SVSulaiman Vesal
Sulaiman Vesal
PGPejman Ghanouni
Pejman Ghanouni
HJHassan Jahanandish
Hassan Jahanandish
MRMirabela Rusu
Mirabela Rusu

1 June 2019
Verified
Conference Paper
Closed access
MJMohammad Hassan Jahanandish
Mohammad Hassan Jahanandish
NFNicholas Fey
Nicholas Fey
KHKenneth Hoyt
Kenneth Hoyt
Control of lower-limb assistive devices would benefit from predicting the intent of individuals in advance of upcoming motion, rather than estimating the current states of their motion. Human lower-limb motion estimation using ultrasound (US) image derived features of skeletal muscle has been demonstrated. However, predictability of motion in time remains an open question. The objective of this study was to assess the predictability of distal lower-limb motion using US image features of rectus femoris (RF) muscle during non-weight-bearing knee flexion/extension. A series of time shifts was introduced between the US features and the joint position in 67 ms steps from 0 ms (i.e., estimation, no prediction) up to predicting 467 ms in advance. A US-based algorithm to estimate lower-limb motion was then used to predict the knee joint position in time using the US features after introducing the time shifts. The accuracy of joint motion prediction after each time shift was compared to the accuracy of joint motion estimation. The reliability of the prediction was then assessed using an analysis of variance (ANOVA) test. The motion prediction accuracy was found to be reliable up to 200 ms, where the average root mean square error (RMSE) of prediction across 9 healthy subjects was 0.89 degrees greater than the average RMSE (7.39 degrees) of motion estimation for the same group of subjects. These findings suggest a reliable prediction of upcoming lower-limb motion is feasible using the US features of skeletal muscle up to a certain point. A reliable prediction may provide lower-limb assistive device control systems with a time-window for processing and control planning, and actuation hence improving the volitional control behaviors of lower-limb assistive devices.

4 October 2021
Verified
Conference Paper
Closed access
MJM. Hassan Jahanandish
M. Hassan Jahanandish
LBLokesh Basavarajappa
Lokesh Basavarajappa
KHKenneth Hoyt
Kenneth Hoyt
Noninvasive ultrasound (US) sensing has been recently introduced as an intuitive human-machine interface. Most research to date has focused on using US images of muscle to predict human movement intentions. However, the richness of unprocessed US signals as a source of neuromuscular information may have been left unnoticed. In the present study, we investigate the feasibility of using unprocessed US signals of muscle tissue to continuously predict knee motion kinematics during seated knee flexion/extension and sit-to-stand movements. Unprocessed US signals were compared to US images using a mutual information analysis to quantify the information gained from each of these US data forms about knee motion. The motion prediction accuracy of unprocessed US signals was compared to motion prediction accuracy of US images. It was observed that a statistically comparable amount of information can be gained from both US data forms $(p\lt 0.05)$. The prediction accuracies were also statistically comparable $(p\lt 0.05)$, and average root mean squared error for knee angle prediction was 1.66° when using unprocessed US signals compared to 2.25° when using US images. Noteworthy, the computation speed was around 33 frames per second (FPS) when using US images compared to 251 FPS when using unprocessed US signals. Overall, this study highlights the promise of unprocessed US signals as a source of neuromuscular information for human motion prediction in real-time, while omitting the signal processing steps required to reconstruct the US images and the associated engineering sophistication, facilitating the future integration of US sensing as a human-machine interface.