10 April 2014 in Radiation Research
In the event of a nuclear incident in a heavily populated area, the surge in demand for medical evaluation will likely overwhelm our emergency care system, compromising our ability to care for victims with life-threatening injuries or exposures. Therefore, there exists a need for a rapidly deployable biological assay for radiation exposure that can be performed in the field by individuals with little to no medical training. Saliva is an attractive biofluid for this purpose, due to the relative ease of its collection and the wide array of biomolecules it contains. To determine whether the human salivary proteome is responsive to ionizing radiation exposure, we characterized the abundances of salivary proteins in humans before and after total body irradiation. Using an assay panel targeting 90 analytes (growth factors, chemokines and cytokines), we identified proteins that were significantly radiation responsive in human saliva. The responses of three proteins (monocyte chemo-attractant protein 1, interleukin 8 and intercellular adhesion molecule 1) were confirmed using independent immunoassay platforms and then verified and further characterized in 130 saliva samples from a completely independent set of 38 patients undergoing total body irradiation. The results demonstrate the potential for detecting radiation exposure based on analysis of human saliva.
2 October 2009 in Genome Research
Although a highly accurate sequence of the Caenorhabditis elegans genome has been available for 10 years, the exact transcript structures of many of its protein-coding genes remain unsettled. Approximately two-thirds of the ORFeome has been verified reactively by amplifying and cloning computationally predicted transcript models; still a full third of the ORFeome remains experimentally unverified. To fully identify the protein-coding potential of the worm genome including transcripts that may not satisfy existing heuristics for gene prediction, we developed a computational and experimental platform adapting rapid amplification of cDNA ends (RACE) for large-scale structural transcript annotation. We interrogated 2000 unverified protein-coding genes using this platform. We obtained RACE data for approximately two-thirds of the examined transcripts and reconstructed ORF and transcript models for close to 1000 of these. We defined untranslated regions, identified new exons, and redefined previously annotated exons. Our results show that as much as 20% of the C. elegans genome may be incorrectly annotated. Many annotation errors could be corrected proactively with our large-scale RACE platform.
1 November 2023 in Clinical Ophthalmology
Purpose: Intraocular pressure (IOP) measurement is critical in diagnosing and managing eye conditions. This study aims to assess the comparability of three alternative devices for measuring IOP: Noncontact tonometer, Icare rebound tonometer, and Tono-Pen. Patients and Methods: A cross-sectional study included 172 adult participants (87 males and 85 females) who underwent IOP and central corneal thickness (CCT) assessments. IOP was measured using Noncontact (Canon TX-20), Icare (Icare TA01i), and Tono-Pen (Tonopen XL). CCT was measured with the built-in pachymetry of the Noncontact tonometer. Correlation coefficients and Bland-Altman analyses were conducted to assess the relationships and agreements between these tonometers. Participants were grouped based on IOP and CCT levels. The mean of the standard deviation of the three tonometer results was calculated to evaluate measurement result variability. One-way analysis of variance was conducted for comparing between the groups. Results: IOP measurements among the three devices were not significantly different, indicating their comparability. Correlation analysis revealed strong correlations between the tonometers. Bland-Altman analysis showed good agreement, with the Icare rebound tonometer and Tono-Pen exhibiting narrower limits of agreement. Furthermore, IOP levels influenced measurement result variability, with higher IOP levels associated with greater variance. Conclusion: This study demonstrates that the alternative devices examined can provide reliable IOP measurements. It highlights the potential of these alternative devices for IOP measurement. These findings have implications for clinical practice, offering practitioners additional tools for accurate IOP assessment.
27 November 2023 in Journal Français d'Ophtalmologie