Birgitta Gleeson

Birgitta Gleeson

Auto-generated profile, based on publicly available information

Birgitta Gleeson

FIND, Geneva, Switzerland

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2024 in The Lancet
Verified
Journal Article
Open access
RPRemco Peters
Remco Peters
JKJeffrey D Klausner
Jeffrey D Klausner
LMLaura Mazzola
Laura Mazzola
MMMandisa M Mdingi
Mandisa M Mdingi
HJHyunsul Jung
Hyunsul Jung
CFCecilia Ferreyra
Cecilia Ferreyra
A rapid and affordable point-of-care test is a priority for Neisseria gonorrhoeae control. WHO and Foundation for Innovative New Diagnostics (FIND) have a target product profile for a non-molecular N gonorrhoeae rapid point-of-care test that requires a clinical sensitivity of greater than 80% and a specificity over 95% to be considered useful in syndromic management; test turnaround time should be 30 min or under, and the test should cost less than US$3. A novel lateral flow assay (LFA) was developed to achieve that profile. In this cross-sectional study we evaluated the performance of the novel N gonorrhoeae lateral flow assay (NG-LFA) at the primary health-care level in South Africa. Male patients with urethral discharge syndrome and female patients with vaginal discharge syndrome were recruited from five primary health-care facilities in the Buffalo City Metropolitan Municipality health district of South Africa. First-void urine specimens and nurse-collected vaginal swabs were tested in-facility with the NG-LFA and Xpert CT/NG PCR assay. N gonorrhoeae multi-antigen sequence typing (NG-MAST) was performed on all LFA positive specimens. Between March 7, and Sept 19, 2022, we enrolled 200 male patients with urethral discharge and 200 female patients with vaginal discharge. The median age of male patients was 24 years (IQR 21-31 years), and the median age of female patients was 25 years (IQR 21-32 years). In addition, 23 male patients and 12 female patients who presented at the facility with a partner notification slip were enrolled of whom one (4%) and five (42%) were symptomatic, respectively. NG-LFA and Xpert results were available for all participants. In urine specimens, NG-LFA sensitivity was 96·1% (Wilson 95% CI 91·2-98·3; 123 LFA-positive among 128 PCR-positive specimens) and 91·7% in vaginal swab specimens (78·2-97·1; 33 LFA-positive among 36 PCR-positive). The specificity was 97·2% in urine specimens (90·4-99·2; 70 LFA-negative among 72 PCR-negative) and 96·3% in vaginal specimens (92·2-98·3; 158 LFA-negative among 164 PCR-negative). In 156 LFA-positive specimens, NG-MAST showed 93 different sequence types. The novel NG-LFA had excellent clinical sensitivity and specificity in symptomatic male and female patients. The test met the optimal requirement for sensitivity and the minimal requirement for specificity specified in the target product profile. NG-LFA could provide an important tool to optimise clinical management and reduce excess antibiotic use in settings without direct access to laboratory testing. Global Antimicrobial Resistance Innovation Fund (GAMRIF) via FIND and National Institutes of Health.

10 September 2024 in BMJ Global Health
Verified
Journal Article
Open access
PDF file
BGBirgitta Gleeson
Birgitta Gleeson
CFCecilia Ferreyra
Cecilia Ferreyra
KPKara Palamounta
Kara Palamounta
SJShevin T Jacob
Shevin T Jacob
NSNaomi Spotswood
Naomi Spotswood
SLSara Liaghati-Mobarhan
Sara Liaghati-Mobarhan

9 January 2024 in BMC Health Services Research
Verified
Journal Article
Open access
PDF file
LVLindsey de Vos
Lindsey de Vos
JDJoseph Daniels
Joseph Daniels
AGAvuyonke Gebengu
Avuyonke Gebengu
LMLaura Mazzola
Laura Mazzola
BGBirgitta Gleeson
Birgitta Gleeson
RPRemco Peters
Remco Peters
Background: South Africa maintains an integrated health system where syndromic management of sexually transmitted infections (STI) is the standard of care. An estimated 2 million cases ofNeisseria gonorrhoeae (N. gonorrhoeae)occur in South Africa every year. Point-of-care diagnostic tests (POCT) may address existing STI control limitations such as overtreatment and missed cases. Subsequently, a rapid lateral flow assay with fluorescence-based detection (NG-LFA) with a prototype reader was developed forN. gonorrhoeaedetection showing excellent performance and high usability; however, a better understanding is needed for device implementation and integration into clinics.Methods: A qualitative, time-series assessment using 66 in-depth interviews was conducted among 25 trained healthcare workers involved in the implementation of the NG-LFA. Findings were informed by the Normalization Process Theory (NPT) as per relevant contextual (strategic intentions, adaptive execution, and negotiation capacity) and procedural constructs (coherence, cognitive participation, collective action, reflexive monitoring) to examine device implementation within primary healthcare levels. Interviews were audio-recorded, transcribed, and then analyzed using a thematic approach guided by NPT to interpret results.Results: Overall, healthcare workers agreed that STI POCT could guide better STI clinical decision-making, with consideration for clinic integration such as space constraints, patient flow, and workload. Perceived NG-LFA benefits included enhanced patient receptivity and STI knowledge. Further, healthcare workers reflected on the suitability of the NG-LFA given current limitations with integrated primary care. Recommendations included sufficient STI education, and appropriate departments for first points of entry for STI screening.Conclusions: The collective action and participation by healthcare workers in the implementation of the NG-LFA revealed adaptive execution within the current facility environment including team compositions, facility-staff receptivity, and STI management experiences. User experiences support future clinic service integration, highlighting the importance of further assessing patient-provider communication for STI care, organizational readiness, and identification of relevant departments for STI screening.

19 December 2023 in Sexually Transmitted Diseases
Verified
Journal Article
Open access
BGBirgitta Gleeson
Birgitta Gleeson
JPJeremie Piton
Jeremie Piton
LMLaura Mazzola
Laura Mazzola
SMSean BS McHugh
Sean BS McHugh
JBJillian Bs Bender
Jillian Bs Bender
CFCecilia Ferreyra
Cecilia Ferreyra
Background: Neisseria gonorrhoeae (NG) has acquired significant resistance, primarily due to extensive and unwarranted antibiotic utilization over several decades. This resistance has largely been associated with the syndromic management of sexually transmitted infections, particularly in low- and middle-income countries where affordable point of care tests are unavailable. To address this diagnostic gap, FIND has developed a low-cost lateral flow assay for the detection of NG at the point of care. Methods: The early performance of the lateral flow assay was evaluated using frozen clinical samples. Limit of detection, inclusivity, and exclusivity studies were performed using well-characterized NG strains, common commensal genital microorganisms, and other Neisseria bacteria. Subsequently, clinical performance was evaluated at 2 sexual health clinics in Birmingham, Alabama. Results: The observed limit of detection with reference NG strains was 5 × 103 CFU/mL. Inclusivity was demonstrated for 31 NG strains. Exclusivity testing showed no cross-reactivity with 28 non-Neisseria and nongonococcal Neisseria species; cross-reactivity was observed with Neisseria meningitidis, Neisseria lactamica, and Neisseria polysaccharea. The lateral flow assay demonstrated clinical sensitivity and specificity of 78.6% and 100% in female vaginal swabs and 100% and 89.7% in male urine, respectively. Conclusions: FIND has developed a lateral flow assay that aligns with the majority of the World Health Organization Target Product Profile criteria for confirming or excluding NG infection at the point of care. The NG lateral flow assay has now achieved design freeze (final device optimization) and is ready for technology transfer to a manufacturing partner. This test has the potential to support the shift in patient management from a syndromic to an etiological approach.

11 February 2025 in PLOS Global Public Health
Verified
Journal Article
Open access
PDF file
KMKevin Martin
Kevin Martin
EDEthel Dauya
Ethel Dauya
CCChido Dziva Chikwari
Chido Dziva Chikwari
CMConstance R. S. Mackworth-Young
Constance R. S. Mackworth-Young
VSVictoria Simms
Victoria Simms
CFCecilia Ferreyra
Cecilia Ferreyra
Affordable, easy-to-use and rapid diagnostics may support a move away from syndromic management for sexually transmitted infections (STIs) in resource-constrained settings. A lateral flow assay for Neisseria gonorrhoeae (NG-LFA) has shown high sensitivity and specificity (>90%) in symptomatic individuals. We investigated the performance and acceptability of this assay as a screening tool for NG among pregnant women. This evaluation was embedded within a prospective study evaluating point-of-care STI screening in pregnant women attending antenatal care (ANC) in Harare, Zimbabwe. Participants were included regardless of symptom status, ANC visit number, or gestational age. Nurse-collected vaginal swabs were tested on-site using the NG-LFA and the Xpert CT/NG assay (Xpert) (reference test). The implementation team members (n=4) were interviewed to assess acceptability and usability of NG-LFA. Of 912 participants, 4.8% (44/912) self-reported presence of abnormal vaginal discharge. Xpert NG prevalence was 4.2% (38/912); 81.6% (31/38) of infections were asymptomatic. The sensitivity, specificity, positive predictive value, and negative predictive value (NPV) of the NG-LFA were 65.8% (25/38; 95% CI 48.6%–80.4%), 99.2% (867/874; 95% CI 98.4–99.7%), 78.1% (25/32; 95% CI 60.0-90.7%), and 98.5% (867/880; 95% CI 97.5-99.2%). The NG-LFA was considered easy-to-use and interpret but discordant results led to issues of trust in the NG-LFA results. Among predominantly asymptomatic pregnant women, the NG-LFA had high specificity, but relatively low sensitivity meaning one in three cases of gonorrhoea were not detected. Further studies are warranted to assess the clinical performance and cost-effectiveness of the NG-LFA in other settings and populations.

1 October 2024 in BMJ Paediatrics Open
Verified
Journal Article
Open access
PDF file
LLLizel Georgi Lloyd
Lizel Georgi Lloyd
ADAngela Dramowski
Angela Dramowski
ABAdrie Bekker
Adrie Bekker
DBDaynia Ballot
Daynia Ballot
CFCecilia Ferreyra
Cecilia Ferreyra
MWMirjam Van Weissenbruch
Mirjam Van Weissenbruch
Background and objectives Neonatal mortality due to severe bacterial infections is a pressing global issue, especially in low-middle-income countries (LMICs) with constrained healthcare resources. This study aims to validate the Neonatal Healthcare-associated infectiOn Prediction (NeoHoP) score, designed for LMICs, across diverse neonatal populations. Methods Prospective data from three South African neonatal units in the Neonatal Sepsis Observational (NeoOBS) study were analysed. The NeoHoP score, initially developed and validated internally in a South African hospital, was assessed using an external cohort of 573 sepsis episodes in 346 infants, focusing on different birth weight categories. Diagnostic metrics were evaluated, including sensitivity, specificity, positive predictive value and area under the receiver operating characteristic curve. Results The external validation cohort displayed higher median birth weight and gestational age compared with the internal validation cohort. A significant proportion were born before reaching healthcare facilities, resulting in increased sepsis evaluation, and diagnosed healthcare-associated infections (HAIs). Gram-negative infections predominated, with fungal infections more common in the external validation cohort. The NeoHoP score demonstrated robust diagnostic performance, with 92% specificity, 65% sensitivity and a positive likelihood ratio of 7.73. Subgroup analysis for very low birth weight infants produced similar results. The score’s generalisability across diverse neonatal populations was evident, showing comparable performance across different birth weight categories. Conclusion This multicentre validation confirms the NeoHoP score as a reliable 'rule-in' test for HAI in neonates, regardless of birth weight. Its potential as a valuable diagnostic tool in LMIC neonatal units addresses a critical gap in neonatal care in low-resource settings.