Division of Oral and Maxillofacial Reconstructive Surgery, Department of Disease Management Dentistry, Tohoku University Graduate School of Dentistry, Sendai, Japan
Auto-generated profile, based on publicly available information
Kensuke Yamauchi
Division of Oral and Maxillofacial Reconstructive Surgery, Department of Disease Management Dentistry, Tohoku University Graduate School of Dentistry, Sendai, Japan
Accidental displacement of a dental implant into the maxillary sinus is an infrequent although not uncommon complication encountered in dental clinical practice, with the main cause thought to be inadequate bone height in the posterior maxilla. We report a case of migration of a dental implant into the maxillary sinus, and discuss the benefits of its removal by a combination of endoscopically assisted and bone repositioning techniques. A 35-year-old Japanese man with a partially edentulous maxilla underwent implant placement at a private clinic. Three months later, at the time of abutment connection, the implant at the site of his maxillary right first molar was accidentally pushed into the sinus. The hole on the alveolar ridge made for placement of the implant was small and far from the dislocated implant, thus access was achieved in a transoral manner via the frontal wall of his maxillary sinus with an endoscopic approach. Piezoelectric instruments were used to perform an osteotomy. The bone lid was removed, and the implant was identified using a rigid endoscope and removed with a surgical aspirator, followed by repositioning of the bony segment; the area was secured with an absorbable suture. Removal of migrated implants should be considered in order to prevent possible sinusal disease complications. In the present case, removal of a dental implant displaced into the maxillary sinus by use of a combination of endoscopically assisted and bone repositioning techniques proved to be a safe and reliable procedure.
1 January 2018 in Journal of Periodontal & Implant Science
Purpose: The purpose of this study was to assess the clinical interventions and the accuracy of maxillary reposition using a computer-aided design/computer-aided manufacturing (CAD/CAM) splint derived via surgical simulation. Materials and Methods: The retrospective study comprised 24 patients who underwent bimaxillary surgery. The patients were assigned to 1 of 2 groups by a way of maxillary repositioning. One group received conventional intermediate wafers and the other CAD/CAM wafers during Le Fort I osteotomy. We recorded operation time, blood loss, the operative accuracy. Accuracy was analyzed by 3-dimensional computed tomography images before and immediately after the operation. The evaluation points were the right maxillary first incisor (U1), the right maxillary second molar (M2-right), and the left maxillary second molar (M2-left). Results: The 2 groups did not differ significantly in operation time and blood losses. The vertical axis of U1 data differed significantly between the 2 groups (P = 0.008). None of the horizontal, vertical, or anteroposterior axis of M2-right data differed significantly, and anteroposterior axis of M2-left data differed significantly (P = 0.0296). The CAD/CAM group 3-dimensional distance errors were less than those of the conventional group for all points. Conclusion: Placement of CAD/CAM splint allowed highly accurate repositioning; the accuracy exceeded that afforded by conventional model surgery using a facebow and articulator.