Keisuke Yagi

Keisuke Yagi

Auto-generated profile, based on publicly available information

Keisuke Yagi

Domain of Mechanical Systems Engineering, Ibaraki University, Hitachi, Japan

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 August 2022 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
MKMaxwell Kennard
Maxwell Kennard
KYKeisuke Yagi
Keisuke Yagi
MHModar Hassan
Modar Hassan
HKHideki Kadone
Hideki Kadone
HMHiromi Mochiyama
Hiromi Mochiyama
KSKenji Suzuki
Kenji Suzuki
Even with proper lifting techniques, fatigue can cause many debilitating injuries. Exoskeleton lumbar support devices help prevent these injuries for workers and improve their overall performance. In this article, we present a study on the performance of a semiactive lower back support exoskeleton. The device is powered by a spring–damper mechanism that utilizes a magnetorheological fluid to add a resistive force to the hip joint. The braking force of the device showed a range between 100 and 900 N depending on the compression stroke, coil current, and actuation speed. Muscle activation of the latissimus dorsi, erector spinae, and gluteus maximus was reduced. The analysis based on a biomechanical model showed a power reduction of 40% at the hip joint in the bending phase, and a total reduction of 20% during the entire lifting cycle. The automatic control system using only embedded sensors showed successful and stable functioning but had excessive delays in the activation of the device.

31 January 2018 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
KYKeisuke Yagi
Keisuke Yagi
KSKenji Suzuki
Kenji Suzuki
HMHiromi Mochiyama
Hiromi Mochiyama
We propose a new wearable device for human joint impedance estimation. The device utilizes snap-through buckling of closed-elastica to impose perturbations on human joints. Actuation is based on the law of momentum conservation, that is, the proposed device induces an impact on human joint dynamics. The snap-through buckling generates a comparatively high velocity even with small actuators, and thus, the device is significantly lighter in weight and more compact compared to conventional systems. In addition, it can impose a torque perturbation on a human joint within a sufficiently short time period. Because of the perturbation in the short period, the estimation algorithm also developed in this letter enables us to consider the resulting response as an impulse response, and thereby no synchronization between the input-output data is required. We conduct pilot tests to verify the proposed method for ankle joint impedance estimation and discuss the basic performance of this method compared to the related work. We also discuss the viability of using this method for a variety of purposes in human joint impedance estimation.

1 December 2020 in IET Control Theory & Applications
Verified
Journal Article
Open access
PDF file
KYKeisuke Yagi
Keisuke Yagi
In this paper, the matched‐pole–zero model which has been widely used for discretisation of a single‐input–single‐output control system described in transfer‐function forms is extended to be applicable to the system in state‐space forms. The matched‐pole–zero model is classified as the discrete‐time model, where poles and transmission zeros are mapped into the discrete‐time domain according to the same discretisation law defined by a certain algebraic relationship. In order to obtain the matched‐pole–zero model, the paper presents an equivalent reconfiguration, which transforms a system into an internal feedback structure around a subsystem based on the principle of control zeros. Discretisation of the subsystem produces a discrete‐time model, where transmission zeros are mapped according to the desired law. The proposed matched‐pole–zero model is obtained by modifying the pole placements of this discrete‐time model. As long as the direct‐term matrix of the underlying system is nonsingular, the proposed model can be obtained algorithmically and is applicable to a multi‐input‐multi–output system without any modification. The paper provides numerical examples verifying that the proposed matched‐pole‐zero model preserves the unique characteristics of the underlying system due to the zeros, such as the blocking and the decoupling properties, and causes smaller discretisation errors than the comparable matched‐pole–zero model.

6 April 2023 in Advanced Robotics
Verified
Journal Article
Closed access
YEYuki Endo
Yuki Endo
KYKeisuke Yagi
Keisuke Yagi
YMYoshikazu Mori
Yoshikazu Mori
TTToshinobu Takei
Toshinobu Takei
HMHiromi Mochiyama
Hiromi Mochiyama
We propose a remote joint impedance estimation system called Tele-snap for a rehabilitation diagnosis under the COVID-19 pandemic. Dynamic resistance of the human joint is essential physical information reflecting the motor function. The resistance is assessed based on the touching sensation of the doctor (physiotherapist), but the pandemic restricts such an in-person manner. Our proposing system aims to provide this physical information quantified by the joint impedance for a diagnosis in the telerehabilitation context. The proposed system employs a compact impulsive perturbation generator called the snap motor and a marker-less motion capture technology called the OpenPose. The subsystem installed in the patient's place is then simplified remarkably, which consists of the wearable snap motor and Raspberry Pi with a built-in camera module. The proposed system can collect the dataset for impedance estimation through the examiner's teleoperation of the snap motor and camera via a virtual private network, with no need for the operation by the patient. We verify the proposed system through an in-person experiment and then demonstrate the remote impedance estimation scheme. GRAPHICAL ABSTRACT

13 September 2023 in Bioinspiration & Biomimetics
Verified
Journal Article
Closed access
KTKiichi Tajima
Kiichi Tajima
KYKeisuke Yagi
Keisuke Yagi
YMYoshikazu Mori
Yoshikazu Mori
We propose an impulsive motion generator inspired by snapping shrimp. The proposed device mimics the geometrical arrangement of a unique claw joint called cocking slip joint and integrates it with an artificial rack-pinion actuator mechanism rather than adopting the musculoskeletal system as it is. The design approach allows the proposed device to reproduce the impulsive slip motion through the torque reversal and unlatching mechanism of the underlying unique joint by using a single servo motor. Static and dynamic analyses revealed that the actuator force required to store and release elastic energy was remarkably small compared with the resulting acceleration force and rotation/tip speed. Through simulations and experiments, we validated the mechanical analyses and confirmed that the resulting ultrafast slip motion was comparable with the claw closure of snapping shrimp based on the cocking slip joint. Moreover, from an engineering perspective, the motion profiles are modifiable through design parameters, and the repeatability of the impulsive slip motion is satisfactory.

22 December 2020 in Advanced Robotics
Verified
Journal Article
Closed access
KYK. Yagi
K. Yagi
YMY. Mori
Y. Mori
HMH. Mochiyama
H. Mochiyama
The paper is concerned with force-sensorless estimation of human joint impedance utilizing an impulsive force. We analyze the dynamic response of a human joint induced by the impulsive perturbation and derive the relationship between the amplitude of the perturbation force and the initial value of the induced angular velocity. This relationship means that the force amplitude required by the estimation algorithm can be replaced with a specific value of the velocity, which leads to eliminating the need for force-sensing. In order to verify the force-sensorless impedance estimation experimentally, a wearable-type snap-through buckling mechanism is employed as the impulsive force generator. The experiments are carried out with a benchmark setup and a healthy male participant. The impedance estimation has been achieved without using any force sensor and performs good consistency with the specific mechanical impedance of the setup and with the ankle impedance reported by related works respectively. The obtained results thus indicate the feasibility of the proposed force-sensorless scheme. GRAPHICAL ABSTRACT