Nuno Loução

Nuno Loução

Auto-generated profile, based on publicly available information

Nuno Loução

Philips Healthcare Iberia, Madrid, Spain

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
LBLinda Bianchini
Linda Bianchini
JSJoão Santinha
João Santinha
NLNuno Loução
Nuno Loução
MFMário Figueiredo
Mário Figueiredo
FBFrancesca Botta
Francesca Botta
Alessandro LascialfariAlessandro Lascialfari
Alessandro Lascialfari

18 December 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
Andrada IanusAndrada Ianus
Andrada Ianus
ISInes Santiago
Ines Santiago
AGAntonio Galzerano
Antonio Galzerano
PMPaula Montesinos
Paula Montesinos
NLNuno Loução
Nuno Loução
NSNoam Shemesh
Noam Shemesh

1 May 2019 in Cancer Research
Verified
Journal Article
Open access
PDF file
ISInês Santiago
Inês Santiago
JSJoão Santinha
João Santinha
Andrada IanusAndrada Ianus
Andrada Ianus
AGAntonio Galzerano
Antonio Galzerano
RTRita Theias
Rita Theias
NSNoam Shemesh
Noam Shemesh
Noninvasive characterization of lymph node involvement in cancer is an enduring onerous challenge. In rectal cancer, pathologic lymph node status constitutes the most important determinant of local recurrence and overall survival, and patients with involved lymph nodes may benefit from preoperative chemo and/or radiotherapy. However, knowledge of lymph node status before surgery is currently hampered by limited imaging accuracy. Here, we introduce Susceptibility-Perturbation MRI (SPI) as a novel source of contrast to map malignant infiltration into mesorectal lymph nodes. SPI involves multigradient echo (MGE) signal decays presenting a nonmonoexponential nature, which we show is sensitive to the underlying microstructure via susceptibility perturbations. Using numerical simulations, we predicted that the large cell morphology and the high cellularity of tumor within affected mesorectal lymph nodes would induce signature SPI decays. We validated this prediction in mesorectal lymph nodes excised from total mesorectal excision specimens of patients with rectal cancer using ultrahigh field (16.4 T) MRI. SPI signals distinguished benign from malignant nodal tissue, both qualitatively and quantitatively, and our histologic analyses confirmed cellularity and cell size were the likely underlying sources for the differences observed. SPI was then adapted to a clinical 1.5 T scanner, added to patients' staging protocol, and compared with conventional assessment by two expert radiologists. Nonmonoexponential decays, similar to those observed in the ex vivo study, were demonstrated, and SPI classified lymph nodes more accurately than standard high-resolution T2-weighted imaging assessment. These findings suggest this simple, yet highly informative, method can improve rectal cancer patient selection for neoadjuvant therapy. Significance: These findings introduce an MRI methodology tailored to detect magnetic susceptibility perturbations induced by subtle alterations in tissue microstructure.

31 March 2023
Verified
Other
Open access
ISInês Santiago
Inês Santiago
JSJoão Santinha
João Santinha
AIAndrada Ianus
Andrada Ianus
AGAntonio Galzerano
Antonio Galzerano
RTRita Theias
Rita Theias
NSNoam Shemesh
Noam Shemesh
Noninvasive characterization of lymph node involvement in cancer is an enduring onerous challenge. In rectal cancer, pathologic lymph node status constitutes the most important determinant of local recurrence and overall survival, and patients with involved lymph nodes may benefit from preoperative chemo and/or radiotherapy. However, knowledge of lymph node status before surgery is currently hampered by limited imaging accuracy. Here, we introduce Susceptibility-Perturbation MRI (SPI) as a novel source of contrast to map malignant infiltration into mesorectal lymph nodes. SPI involves multigradient echo (MGE) signal decays presenting a nonmonoexponential nature, which we show is sensitive to the underlying microstructure via susceptibility perturbations. Using numerical simulations, we predicted that the large cell morphology and the high cellularity of tumor within affected mesorectal lymph nodes would induce signature SPI decays. We validated this prediction in mesorectal lymph nodes excised from total mesorectal excision specimens of patients with rectal cancer using ultrahigh field (16.4 T) MRI. SPI signals distinguished benign from malignant nodal tissue, both qualitatively and quantitatively, and our histologic analyses confirmed cellularity and cell size were the likely underlying sources for the differences observed. SPI was then adapted to a clinical 1.5 T scanner, added to patients' staging protocol, and compared with conventional assessment by two expert radiologists. Nonmonoexponential decays, similar to those observed in the ex vivo study, were demonstrated, and SPI classified lymph nodes more accurately than standard high-resolution T2-weighted imaging assessment. These findings suggest this simple, yet highly informative, method can improve rectal cancer patient selection for neoadjuvant therapy.Significance:These findings introduce an MRI methodology tailored to detect magnetic susceptibility perturbations induced by subtle alterations in tissue microstructure.

31 March 2023
Verified
Other
Open access
ISInês Santiago
Inês Santiago
JSJoão Santinha
João Santinha
AIAndrada Ianus
Andrada Ianus
AGAntonio Galzerano
Antonio Galzerano
RTRita Theias
Rita Theias
NSNoam Shemesh
Noam Shemesh
Figure S1. Raw data from MGE MRI on a representative patient in-vivo at 1.5 T.

14 May 2026 in The Breast
Verified
Journal Article
Open access
RTRafaela Timóteo
Rafaela Timóteo
ALAlexandre Laborde
Alexandre Laborde
BVBruno Vaz
Bruno Vaz
NLNuno Loução
Nuno Loução
YFYasna Forghani
Yasna Forghani
PGPedro Gouveia
Pedro Gouveia
Inaccurate tumor localization in breast-conserving surgery (BCS) can lead to positive margins and re-excision. In this technical pilot study, Digital Twins (DT) were used for non-invasive tumor localization in the operating room. Breast DTs were generated from supine breast magnetic resonance imaging and registered to patients in real-time using a 3D sensing system during four surgeries. Alignment accuracy was measured via nipple deviations (0-5 mm). Setup and marking times were clinically acceptable, with high perceived usability (SUS = 95). These preliminary results demonstrate the potential of integrating DTs into surgical workflows.