Hanpei Xu

Hanpei Xu

Auto-generated profile, based on publicly available information

Hanpei Xu

College of Optoelectronic Engineering, National Key Laboratory of Fundamental Science, Novel Micro/Nano Device and System Technology, and the Key Laboratory of Optoelectronic Technology and System, Education Ministry of China, Chongqing University, Chongqing, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 December 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
ZWZhuang Wang
Zhuang Wang
JWJiahui Wang
Jiahui Wang
HXHanpei Xu
Hanpei Xu
QWQuan Wen
Quan Wen
DLDongling Li
Dongling Li
JLJinhua Li
Jinhua Li
Accurate gas detection is essential for mitigating harmful gas emissions and ensuring production safety. This study introduces an FR4-based tunable Fabry-Pérot (F-P) filter equipped with an electromagnetic actuator to address the precision limitations of conventional gas detectors. Simulations and analyses were performed on distributed Bragg reflectors with various multilayer film configurations on silicon and silicon dioxide substrates. Results indicate that a five-layer (poly-Si/SiO 2 ) membrane stack reflector achieves a high reflectance of 98.51%, enabling the filter to attain a Full Width at Half Maximum ( FWHM ) of 0.9 nm and a free spectral range ( FSR ) of 173.6 nm. To overcome the challenges of limited cavity length control in the F-P cavity, a novel electromagnetically actuated cascaded folded beam structure, designed via finite element analysis, is proposed. This mechanism achieves a reflector displacement of 1.6 μm under a low actuating voltage of 30 mV while maintaining a parallelism finesse exceeding 300. Additionally, the system achieves a displacement tuning precision of 22.7 nm/mA, surpassing existing designs, and the displacement adjustment error below 20 nm. Experimental validation demonstrated an excellent linear correlation (R²=0.9998) between the applied signals and reflector displacements, facilitating precise wavelength control. The proposed methane detection system, based on the electromagnetic F-P tunable filter, exhibits significant potential for high-precision methane monitoring in environmental and industrial applications.

19 April 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
YZYuanyuan Zhou
Yuanyuan Zhou
HXHanpei Xu
Hanpei Xu
XYXingquan Yuan
Xingquan Yuan
QWQuan Wen
Quan Wen
DLDongling Li
Dongling Li
Micro-gratings have become pivotal components in advanced optical systems, offering precise light manipulation and analysis. However, achieving a high spectral resolution and enlarged scanning angles without sacrificing linearity remains a challenging endeavor. This paper presents an electromagnetically driven micro-grating designed to address these challenges. To achieve these enhancements, our work employs a multi-degree-of-freedom resonator design which comprises a grating, an actuator coil frame, an integrated angle sensor, and four cantilever torsion springs. The scanning angle amplification effect is realized through optimizing the MIMO (Multiple-Input-Multiple-Output) behavior associated with the system’s second-order harmonic. With the amplification effect of scanning angle, a minor displacement in the actuator coil frame can achieve a significant scanning angle on the grating. A theoretical model of proposed multi-degree-of-freedom design has been established together with a finite element simulation model. The potential optimization parameters have been analyzed and discussed in detail. We fabricated a demonstrator based on Flame-Retardant-4 material, and the experiment results showed the device with mirror size 12mm × 12mm could reach a 6.94° scanning angle with a 75 mArms drive current. The amplification ratio of 1.84 (drive coil 3.77°) could be observed aligning well with harmonic simulation’s prediction. Also, The micro-grating exhibits excellent linearity with a correlation coefficient of 0.99979.