Shuo Tang

Shuo Tang

Auto-generated profile, based on publicly available information

Shuo Tang

Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC, Canada

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2009 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
STShuo Tang
Shuo Tang
WJWoonggyu Jung
Woonggyu Jung
DMDaniel T. McCormick
Daniel T. McCormick
TXTuqiang Xie
Tuqiang Xie
JSJiangping Su
Jiangping Su
ZCZhongping Chen
Zhongping Chen
Multiphoton microscopy (MPM) is an important tool for high-resolution, noninvasive imaging of thick biological tissues.1, 2, 3, 4, 5 MPM utilizes femtosecond lasers to excite nonlinear contrast signals that include two-photon excited fluorescence (TPEF) and second-harmonic generation (SHG). TPEF can be detected from intrinsic sources (e.g., cofactors, proteins) and exogenous fluorophores, while strong SHG signals can be obtained from noncentrosymmetric molecules such as collagen, a common extracellular matrix protein. Thus, MPM can image and distinguish cellular and extracellular matrix structures simultaneously. MPM systems have been mostly developed using free-space optics and microscope platforms. However, for in vivo imaging and clinical applications, a fiber-optic MPM endoscope is desirable where light can be delivered through a flexible fiber and images can be acquired using a miniature probe.6, 7, 8, 9 Delivering femtosecond pulses through fibers and designing miniature scanning probes are two challenges in MPM endoscopy.

1 January 2009 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
STShuo Tang
Shuo Tang
JLJian Liu
Jian Liu
TKTatiana B. Krasieva
Tatiana B. Krasieva
ZCZhongping Chen
Zhongping Chen
BTBruce Jason Tromberg
Bruce Jason Tromberg
We implement a fiber-delivered compact femtosecond fiber laser at 1030-nm wavelength in multiphoton imaging. The laser pulse duration is 150 fs, the average power is 200 mW, and the repetition rate is 40 MHz. The laser measures 200×160×45 mm in size and its output is delivered through a photonic bandgap fiber. Intrinsic second-harmonic generation signal is excited from rat tail tendon and human skin samples. Two-photon excited fluorescence signal is obtained from human skin tissues stained with exogenous fluorophore. Our results show that femtosecond fiber lasers at 1030-nm wavelength have significant potential in developing compact, all-fiber-based, portable multiphoton systems and endoscopes. Multiphoton microscopy (MPM), including two-photon excited fluorescence (TPEF) and second-harmonic generation (SHG), has become an important tool for high-resolution, noninvasive imaging of thick biological tissues.1, 2, 3 In TPEF, fluorescence from endogenous or exogenous fluorophores is excited by two-photon absorption. SHG is a nonlinear scattering process where two excitation photons are converted into light that is half the wavelength (twice the energy) of the excitation source. TPEF and SHG imaging can provide complementary information about cellular and extracellular matrix structures.4 Recently there has been tremendous effort to develop compact multiphoton systems for in vivo imaging and clinical applications. In compact systems, femtosecond pulses from ultrafast lasers are coupled into double cladding photonic crystal fibers (PCFs)5, 6, 7 or hollow core photonic bandgap fibers (PBFs).8, 9 Fiber-connected miniature scanning probes are developed to provide flexible access to tissues and acquire MPM images.8, 9, 10 While the probes are becoming smaller and smaller, the sources that they have used are still the traditional solid-state Ti:sapphire lasers which are bulky, expensive, not portable, and require precise alignment. Finding new ultrafast laser sources that are low cost, compact, and portable is expected to enhance the impact of MPM in research and particularly in clinical studies. Semiconductor lasers have been recently demonstrated for MPM imaging.11, 12, 13 By frequency doubling a 1540-nm gain-switched semiconductor laser, Yokoyama have developed a pulsed source with 5-ps pulse duration at 770-nm wavelength, and applied the source for MPM imaging of actin filaments in PtK2 cells.11 Using a gain-switched semiconductor laser, Taira developed a 980-nm wavelength source with 3.5-ps pulse duration and obtained MPM images of mouse kidney tissues.13 The pulsewidth of those semiconductor lasers is limited to several picoseconds, which cannot excite MPM signals as efficiently as femtosecond pulses. Recently, femtosecond fiber lasers have emerged as a promising compact light source for MPM applications.14, 15, 16 Millard used a 1560-nm wavelength femtosecond fiber laser for third-harmonic generation (THG).14 Unruh applied a frequency doubled 1560-nm wavelength femtosecond fiber laser for two-photon fluorescence correlation spectroscopy (FCS).15 The 1560-nm femtosecond fiber lasers and their frequency doubled versions were still output into free space. Therefore, they lacked the capability of direct fiber delivery of femtosecond pulses from the laser sources. Femtosecond fiber lasers at 1030-nm fundamental wavelength have not been reported in MPM applications. There are several advantages of using the 1030-nm wavelength for MPM. Exploring longer wavelength excitation for MPM can potentially reduce tissue scattering and increase imaging depth in turbid tissues. The 1030-nm wavelength band can be used to excite a large selection of fluorescent proteins and dyes that have been originally developed for confocal and fluorescence imaging.13, 16, 17 Squirrell showed that two-photon imaging using 1047-nm excitation wavelength maintained embryo viability over the long term.17 In this work, we introduce a compact short-pulsed, high-power, fiber-delivered femtosecond fiber laser at 1030-nm wavelength for MPM applications. The main advantage of using the fiber laser is the compactness of the laser source and fiber delivery of femtosecond pulses, which makes it an ideal source for developing compact and portable MPM systems. Such advantages are demonstrated by coupling the fiber laser to an MPM microscope system to provide excitation wavelength at 1030nm , and implementing the fiber laser in an all-fiber connected multiphoton spectroscopy system. The femtosecond fiber laser (PolarOnyx, Sunnyvale, California) is composed of an oscillator that generates seed femtosecond pulses, and an amplifier that boosts the power to 200mW . In the oscillator, a high concentration Yb-doped PCF is used as the gain medium. A 980-nm pump laser pumps Yb ions for amplification of intracavity pulses. Passive mode locking is achieved through nonlinear polarization evolution in the slightly birefringent fiber laser cavity.18 Polarization filtering is through a fiber-based inline polarization isolator and polarization controllers inside the laser cavity. Amplification of the seed pulse is achieved by using a short piece of high concentration double cladding Yd-doped fiber pumped with another 980-nm pump laser. After the amplifier, a piece of PBF is used to compress the pulsewidth. The PBF can provide ∼−100ps∕nm∕km anomalous group velocity dispersion (GVD) to compress positively chirped pulses from the amplifier. The output fiber is terminated with an FC/APC fiber connector to deliver femtosecond pulses. Figures 1a and 1b show the spectrum and autocorrelation trace of the laser output. The pulse duration is 150fs measured at the end of the output fiber, and the spectral bandwidth is 20nm , which brings the time-bandwidth product of the laser to be ∼0.8 . The pulse is not transform limited, and the residue chirp is mainly due to higher order dispersion from the fibers. The laser output power is 200mW and pulse repetition rate is ∼40MHz . The fiber laser has a highly compact size of 200×160×45mm , including the oscillator, amplifier, and pump lasers. <!-- named anchor --> Fig. 1 Characteristics of the femtosecond fiber laser: (a) spectrum and (b) autocorrelation trace. The insertion shows a photograph of the packaged fiber laser. Due to its compact size, the fiber laser can be conveniently coupled to any MPM microscope systems to provide excitation wavelengths at 1030nm . In our experiment, the output of the fiber laser is collimated and coupled into an MPM scanning microscope. Details about the MPM microscope can be found in Ref. 19. Figures 2a and 2b show the MPM images excited with the 1030-nm wavelength fiber laser. Figure 2a shows the backward SHG imaging of rat tail tendon where the collagen fiber bundles are observed. Figure 2b shows the TPEF imaging of the cross section (side view) of ex vivo human skin. The skin sample is stained with yellow-orange vital nuclear dye, and the cellular structure of the skin is captured by the TPEF imaging. In Fig. 2b, the TPEF signal is mainly from the epidermis (outer) layer of the skin, which is cellular. The dermis (inner) layer shows little TPEF signal because it is mainly composed of an extracellular matrix. In this experiment, no dispersion compensation is applied to simplify the system design. Therefore, to minimize pulse broadening of the excitation light, a 10×(0.3NA) objective is used that has less dispersion than a high NA objective. The excitation power at the sample location is ∼20mW . The images have 256×256pixels , and the acquisition time is ∼6s /frame. Higher image resolution can be achieved by using a high NA objective and implementing dispersion precompensation to maintain short pulse at the sample location. <!-- named anchor --> Fig. 2 Multiphoton images excited with the femtosecond fiber laser. (a) SHG image from rat tail tendon. (b) TPEF image from ex vivo human skin stained with nuclear vital dye. The scale bar is 50μm . To take full advantage of the fiber delivery of femtosecond pulses, the fiber laser is implemented in an all-fiber connected multiphoton spectroscopy system. Figure 3a shows the schematic of the experimental setup. Femtosecond pulses from the fiber laser are delivered to the tissue site by PBF. At the end of the PBF, the laser power is 200mW and the pulsewidth reaches the minimum of 150fs . Thus, MPM signal can be excited from the proximate area of the end of the excitation fiber. Signal collection is through a fiber bundle positioned next to the excitation fiber. The other side of the fiber bundle is coupled to a spectrograph (SpectraPro-150, Acton Research, Princeton Instruments, Trenton, New Jersey) with a grating of 300grooves∕mm blazed at 500-nm wavelength, followed by a cooled charge-coupled device (CCD) camera (NTE/CCD-512-EBFT, Princeton Instruments, Trenton, New Jersey). Figure 3b shows the spectrum of intrinsic MPM signal excited from ex vivo human skin without staining. A 5-s integration time is used. As shown by the solid line, a strong peak is observed at 515nm , which corresponds to the SHG signal excited by the 1030-nm wavelength. The strong SHG signal is excited from the dermis layer, composed mostly of collagen fibers. From the epidermis layer, very low SHG signal is observed, as shown by the dotted line. Due to the long excitation wavelength, very low autofluorescence is excited from the skin sample. <!-- named anchor --> Fig. 3 (a) Schematic of the MPM spectroscopy system using the fiber laser. (b) MPM spectrum excited from human skin. Solid line: spectrum from dermis layer; doted line: spectrum from epidermis layer. Figure 4 shows the comparison of MPM imaging of human skin excited with 1030- and 800-nm wavelengths. The images are obtained using a Zeiss LSM510, where the laser source (Chameleon, Coherent, Santa Clara, California) can be tuned to 1030 and 800nm , respectively. A 40×water NA=0.8 objective is used. The laser power before the objective is ∼15mW in both cases. For the SHG channel, bandpass filters of 500to530nm and 390to465nm are used for 1030- and 800-nm excitation, respectively. The TPEF channel is filtered with a 535to590-nm bandpass filter. Both images are collected in a backward mode. In Fig. 4a, bright SHG but very low TPEF signal is observed when 1030-nm excitation is used. In Fig. 4b, both SHG and TPEF signals are observed from the same sample when 800nm excitation is used. In Fig. 4b, the TPEF signal shows in yellow, because the 390to465-nm filter also collects some TPEF signal in the SHG channel. In our study, only a gradual decrease in backward SHG intensity is observed when the excitation moves to longer wavelengths. From 800to1030nm , a ∼50% drop in the SHG intensity is observed, which can be compensated by increasing the laser power by 140%. Therefore, SHG imaging can be implemented using a wide range of laser wavelengths. Figure 4a also shows that the autofluorescence background is largely reduced when excitation moves to 1030nm . This property can be used to provide highly specific fluorescence imaging with no autofluorescence background when used together with exogenous fluorophores. <!-- named anchor --> Fig. 4 Comparison of MPM imaging of human skin using 1030- and 800-nm wavelength excitation. (a) Human skin excited by 1030-nm wavelength. (b) The same sample excited by 800-nm wavelength. SHG and TPEF are color coded in green and red, and the overlapping areas are in yellow. Scale bar is 50μm . In conclusion, we have implemented a compact, all-fiber-based femtosecond fiber laser in multiphoton imaging and spectroscopy at the wavelength band of

11 December 2012 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
YZYifeng Zhou
Yifeng Zhou
KCKenny K. H. Chan
Kenny K. H. Chan
TLTom Lai
Tom Lai
STShuo Tang
Shuo Tang
We present a noninvasive method for characterizing the refractive index (RI) and thickness distribution in biological tissues using a combined multiphoton microscopy (MPM) and optical coherence tomography (OCT) system. Tissue layers are distinguished by the MPM and OCT images, and the RI and thickness of each layer are determined by analyzing the co-registered MPM and OCT images. The precision of this method is evaluated on four standard samples which are water, air, immersion oil and cover glass. Precision of within ~1% error compared to reference values is obtained. Biological tissue measurement is demonstrated on fish cornea. Three layers are detected, which are identified as the epithelium and stroma I and II of the cornea. The corresponding RI of each layer is measured to be ~1.446–1.448, 1.345–1.372, and 1.392–1.436, respectively. The difference of RI in the three layers correlates with the tissue compositions including cells in epithelium, large collagen fiber bundles in stroma I, and small collagen fibers in stroma II. The combined MPM/OCT technique is shown to be able to distinguish tissue layers through biochemically specific contrasts and measure RI and thickness of tissue layers at different depths.

4 November 2010 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
KCKenny K. H. Chan
Kenny K. H. Chan
STShuo Tang
Shuo Tang
The useful imaging range in spectral domain optical coherence tomography (SD-OCT) is often limited by the depth dependent sensitivity fall-off. Processing SD-OCT data with the non-uniform fast Fourier transform (NFFT) can improve the sensitivity fall-off at maximum depth by greater than 5dB concurrently with a 30 fold decrease in processing time compared to the fast Fourier transform with cubic spline interpolation method. NFFT can also improve local signal to noise ratio (SNR) and reduce image artifacts introduced in post-processing. Combined with parallel processing, NFFT is shown to have the ability to process up to 90k A-lines per second. High-speed SD-OCT imaging is demonstrated at camera-limited 100 frames per second on an ex-vivo squid eye.

20 July 2021 in Biomedical Optics Express
Verified
Journal Article
Closed access
XZXin Zhou
Xin Zhou
SMSina Maloufi
Sina Maloufi
DLDaniel C. Louie
Daniel C. Louie
NZNing Zhang
Ning Zhang
QLQihao Liu
Qihao Liu
STShuo Tang
Shuo Tang
The depolarization property of skin has been found to be important for skin cancer detection. Previous techniques based on light polarization lack the capability of depth differentiation. Polarization-sensitive optical coherence tomography (PS-OCT) has the advantage of both depth-resolved 3D imaging and high sensitivity to polarization. In this study, we investigate the depolarization property of skin tissue using PS-OCT, especially with the degree of polarization uniformity (DOPU) contrast. Well designed skin phantoms with various surface roughness levels and optical properties mimicking skin are imaged by PS-OCT and the DOPU values are quantified. The result shows a correlation between DOPU and surface roughness, where a higher roughness corresponds to a lower DOPU value. An index matching experiment with a water layer confirms the impact of surface condition on light depolarization. Refraction of backscattered photons on the surface boundary is attributed to the broadening of backscattering angle and thus depolarization. To the best of our knowledge, this is the first time the impact of surface roughness on DOPU is reported and its mechanism explained. Furthermore, through preliminary in vivo skin imaging, the capability of DOPU in detecting depolarization in skin is demonstrated. By utilizing the 3D imaging from PS-OCT, DOPU can offer a high-resolution depth differentiation and quantification of depolarization in skin tissue.

19 April 2016 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
LHLin Huang
Lin Huang
AMArthur K. Mills
Arthur K. Mills
YZYuan Zhao
Yuan Zhao
DJDavid J. Jones
David J. Jones
STShuo Tang
Shuo Tang
We report on a miniature fiber-optic multiphoton microscopy (MPM) system based on a frequency-doubled femtosecond Er-doped fiber laser. The femtosecond pulses from the laser source are delivered to the miniature fiber-optic probe at 1.58 µm wavelength, where a standard single mode fiber is used for delivery without the need of free-space dispersion compensation components. The beam is frequency-doubled inside the probe by a periodically poled MgO:LiNbO3 crystal. Frequency-doubled pulses at 786 nm with a maximum power of 80 mW and a pulsewidth of 150 fs are obtained and applied to excite intrinsic signals from tissues. A MEMS scanner, a miniature objective, and a multimode collection fiber are further used to make the probe compact. The miniature fiber-optic MPM system is highly portable and robust. Ex vivo multiphoton imaging of mammalian skins demonstrates the capability of the system in imaging biological tissues. The results show that the miniature fiber-optic MPM system using frequency-doubled femtosecond fiber laser can potentially bring the MPM imaging for clinical applications.