Qinfang Miao

Qinfang Miao

Auto-generated profile, based on publicly available information

Qinfang Miao

School of Biomedical Engineering & State Key Laboratory of Advanced Medical Materials and Devices ShanghaiTech University Shanghai China

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 September 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
HHHongzhang Huang
Hongzhang Huang
ZZZijian Zhou
Zijian Zhou
ZLZhenfeng Lyu
Zhenfeng Lyu
QMQinfang Miao
Qinfang Miao
GCGenqiang Chen
Genqiang Chen
HQHaikun Qi
Haikun Qi

19 March 2026 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Closed access
QMQinfang Miao
Qinfang Miao
YSYefei Shi
Yefei Shi
BLBo Li
Bo Li
RLRui Luo
Rui Luo
KYKe Yang
Ke Yang
HQHaikun Qi
Haikun Qi

5 August 2025 in medRxiv
Verified
Preprint
Open access
PDF file
QMQinfang Miao
Qinfang Miao
HHHongzhang Huang
Hongzhang Huang
ZLZhenfeng Lyu
Zhenfeng Lyu
WLWenjian Liu
Wenjian Liu
TWTianyi Wu
Tianyi Wu
HQHaikun Qi
Haikun Qi
Background: Myocardial T1 and T2 mapping provide a non-invasive quantitative assessment of cardiac tissue. While established at 1.5-T and 3.0-T MRI, the mapping performance and reference values at 5.0-T MRI remain to be investigated. This study aims to evaluate the feasibility and establish reference values for cardiac T1 and T2 mapping at 5.0-T MRI in healthy subjects. Methods: In this prospective study, 50 healthy volunteers underwent cardiac MRI at both 3.0-T and 5.0-T MRI systems from February to April 2025. Mapping protocols included MOdified Look Locker Inversion recovery (MOLLI, T1), T2-prepared gradient-echo (T2-prep-GRE, T2), and a simultaneous multi-parametric mapping technique (Multimap, T1 and T2). At 3.0-T MRI, both balanced steady-state free precession (bSSFP) and fast low-angle shot (FLASH) readouts were employed, while only the FLASH readout was used at 5.0-T MRI. Intra-observer, inter-observer, and scan-rescan reproducibility were assessed. Statistical analyses included coefficient of variation (CoV), intraclass correlation coefficient (ICC), and Bland-Altman analysis. Results: All techniques at 5.0-T MRI yielded high-quality, artifact-free images. Native T1 values were significantly higher at 5.0 T than at 3.0-T MRI (MOLLI: 1452.9 ± 33.2 ms vs. 1305.9 ± 38.3 ms, P < 0.0001), while T2 values were significantly lower (T2-prep-GRE: 37.53 ± 1.74 ms vs. 43.97 ± 2.95 ms, P < 0.0001). Scan-rescan reproducibility at 5.0 T (ICC: 0.87–0.92; CoV: 2.41%–3.25%) was comparable to 3.0-T MRI. The measurement precision of 5.0 T was higher than 3.0-T MRI with FLASH readout and slightly inferior to bSSFP-based techniques. Multimap achieved efficient, simultaneous T1 and T2 quantification with acceptable reproducibility at 5.0-T MRI. Conclusion: Myocardial T1 and T2 mapping at 5.0-T MRI are reliable and reproducible in healthy individuals, offering reference values for normal myocardium at this field strength. The good measurement reproducibility and precision of 5.0-T cardiac mapping support its clinical potential for myocardial tissue characterization.

17 August 2026 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
QMQinfang Miao
Qinfang Miao
HHHongzhang Huang
Hongzhang Huang
ZLZhenfeng Lyu
Zhenfeng Lyu
WLWenjian Liu
Wenjian Liu
TWTianyi Wu
Tianyi Wu
HQHaikun Qi
Haikun Qi

1 June 2026 in Radiology: Cardiothoracic Imaging
Verified
Journal Article
Closed access
QMQinfang Miao
Qinfang Miao
WZWenjing Zhao
Wenjing Zhao
ZLZhenfeng Lyu
Zhenfeng Lyu
HHHongzhang Huang
Hongzhang Huang
Yan ChenYan Chen
Yan Chen
HQHaikun Qi
Haikun Qi
Multiparametric cardiac MRI depicted dynamic, region-specific progression from inflammation to fibrosis in autoimmune myocarditis, with T2 mapping and extracellular volume fraction supporting stage-specific tissue characterization.