Rasmus Tyrsted Mikkelsen

Rasmus Tyrsted Mikkelsen

Auto-generated profile, based on publicly available information

Rasmus Tyrsted Mikkelsen

Section for Hip and Knee Replacement, Department of Orthopaedic Surgery, Vejle Hospital, Vejle, Denmark

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 June 2023 in Acta Orthopaedica
Verified
Journal Article
Open access
PDF file
RMRasmus Tyrsted Mikkelsen
Rasmus Tyrsted Mikkelsen
SOSøren Overgaard
Søren Overgaard
APAlma B Pedersen
Alma B Pedersen
JKJohan Kärrholm
Johan Kärrholm
MPMartin Paulsson
Martin Paulsson
CVClaus Varnum
Claus Varnum
Background and purpose: The bearings with the best survivorship for young patients with total hip arthroplasty (THA) should be identified. We compared hazard ratios (HR) of revision of primary stemmed cementless THAs with metal-on-metal (MoM), ceramic-on-ceramic (CoC), and ceramic-on-highly-crosslinked-polyethylene (CoXLP) with that of metal-on-highly-crosslinked-polyethylene (MoXLP) bearings in patients aged 20–55 years with primary osteoarthritis or childhood hip disorders.Patients and methods: From the Nordic Arthroplasty Register Association dataset we included 1,813 MoM, 3,615 CoC, 5,947 CoXLP, and 10,219 MoXLP THA in patients operated on between 2005 and 2017 in a prospective cohort study. We used the Kaplan–Meier estimator for THA survivorship and Cox regression to estimate HR of revision adjusted for confounders (including 95% confidence intervals [CI]). MoXLP was used as reference. HRs were calculated during 3 intervals (0–2, 2–7, and 7–13 years) to meet the assumption of proportional hazards.Results: Median follow-up was 5 years for MoXLP, 10 years for MoM, 6 years for CoC, and 4 years for CoXLP. 13-year Kaplan–Meier survival estimates were 95% (CI 94–95) for MoXLP, 82% (CI 80–84) for MoM, 93% (CI 92–95) for CoC, and 93% (CI 92–94) for CoXLP bearings. MoM had higher 2–7 and 7–13 years’ adjusted HRs of revision (3.6, CI 2.3–5.7 and 4.1, CI 1.7–10). MoXLP, CoC, and CoXLP had similar HRs in all 3 periods. The 7–13-year adjusted HRs of revision of CoC and CoXLP were statistically non-significantly higher.Conclusion: In young patients, MoXLP for primary cementless THA had higher revision-free survival and lower HR for revision than MoM bearings. Longer follow-up is needed to compare MoXLP, CoC, and CoXLP.

1 September 2017 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
RMRasmus T. Mikkelsen
Rasmus T. Mikkelsen
MFMarianne Fløjstrup
Marianne Fløjstrup
CLChristian Lund
Christian Lund
PKPer Kjærsgaard-Andersen
Per Kjærsgaard-Andersen
TSThomas Skjødt
Thomas Skjødt
CVClaus Varnum
Claus Varnum

16 September 2014 in Interactive CardioVascular and Thoracic Surgery
Verified
Journal Article
Open access
PDF file
LTLars L. Thomsen
Lars L. Thomsen
RMRasmus T. Mikkelsen
Rasmus T. Mikkelsen
MDMiroslawa Derejko
Miroslawa Derejko
HSHenrik Daa Schrøder
Henrik Daa Schrøder
PLPeter Licht
Peter Licht
Thoracoscopic sympathectomy is now used routinely to treat patients with disabling primary hyperhidrosis or facial blushing. Published results are excellent, but side effects, such as compensatory sweating, are also very frequent. The surgical techniques used and the levels of targeting the sympathetic chain vary tremendously. Most surgeons transect or resect the sympathetic chain, but application of a metal clip that blocks transmission of nerve impulses in the sympathetic chain is used increasingly worldwide. This approach offers potential reversibility if patients regret surgery, but the question of reversibility remains controversial. Two recent experimental studies found severe histological signs of nerve damage 4–6 weeks after clip removal, but they only used conventional histopathological staining methods. Thoracoscopic clipping of the sympathetic trunk was performed in adult sheep, and the clip was removed thoracoscopically after 7 days. Following another 4 weeks (n = 6) or 12 weeks (n = 3), the sympathetic trunks were harvested and analysed by conventional and specific nerve tissue immunohistochemical stains (S100, neurofilament protein and synaptophysin). The contralateral sympathetic chains were used as controls. Conventional and immunohistochemical stains demonstrated severe signs of neural damage on the operated side 4 weeks after clip removal. After 12 weeks, these changes had decreased markedly and conventional histology had almost normalized. Conventional and immunohistochemical stains confirmed that application of metal clips to the sympathetic chain caused severe histological damage in the sympathetic trunk that remained visible 4 weeks after clip removal. However, after 12 weeks, these signs of damage had clearly decreased, which suggests in theory that application of metal clips to the sympathetic chain is a reversible procedure if only the observation period is prolonged. Further studies with longer periods between application and removal as well as investigations of nerve conduction should be encouraged, because we do not know whether histological reversibility at cellular level translates into physiological reversibility and possible correlation of nerve trauma with the duration of the applied clip.

8 February 2023 in Acta Radiologica Open
Verified
Journal Article
Open access
RMRasmus T Mikkelsen
Rasmus T Mikkelsen
MSMartin Schou
Martin Schou
TTTrine Torfing
Trine Torfing
OGOle Graumann
Ole Graumann
SOSøren Overgaard
Søren Overgaard
CVClaus Varnum
Claus Varnum
Background: Metal artifact reduction sequence magnetic resonance imaging (MRI) scan is a common method to detect adverse reaction to metal debris in total hip arthroplasty (THA). It might be quicker and cheaper if ultrasonography (US) could screen for the need for an MRI. However, both require trained personnel. Purpose: We aimed to investigate the sensitivity and specificity of US for detecting pseudotumors (PT) when performed by an orthopedic surgery resident compared to MRI. We also investigated the sensitivity and specificity of US to detect PTs in obese and non-obese patients. Material and methods: We examined 205 patients with hip resurfacing arthroplasty, metal-on-metal or metal-on-polyethylene THA with both MRI and US. US was performed by an orthopedic surgery resident who was trained according to a standardized training program in musculoskeletal US. Results from MRI were used as gold standard. Results: US had a sensitivity of 0.92 (95% CI 0.81–0.98) and specificity of 0.94 (95% CI 0.89–0.97) for detecting PT. It had a positive predictive value of 0.84 (95% CI 0.73–0.91) and a negative predictive value of 0.97 (95% CI 0.93–0.99). US performed similarly in obese and non-obese patients. Conclusions: US had a high sensitivity and specificity for detecting PT when performed by an orthopedic surgery resident. Trained orthopedic surgeons could screen for the need of an MRI scan when searching PTs.

1 July 2018 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
RMRasmus T. Mikkelsen
Rasmus T. Mikkelsen
MFMarianne Fløjstrup
Marianne Fløjstrup
NKNicolai Klem
Nicolai Klem
RTRaymond Andre Tellefsen
Raymond Andre Tellefsen
CLChristian Lund
Christian Lund
CVClaus Varnum
Claus Varnum

1 March 2015
Verified
Journal Article
Closed access
LTLars Thomsen
Lars Thomsen
JLJes Sanddal Lindholt
Jes Sanddal Lindholt
OROle Roeder
Ole Roeder
AGAnders Green
Anders Green
RMRasmus Mikkelsen
Rasmus Mikkelsen