Samah Kamel Elshamndy

Samah Kamel Elshamndy

Auto-generated profile, based on publicly available information

Samah Kamel Elshamndy

Physics Department, College of Science, Jouf University, Sakaka 2014, Saudi Arabia

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 July 2023 in Physica Scripta
Verified
Journal Article
Closed access
MHMohamed Asran Hassan
Mohamed Asran Hassan
ECE V Chernyshova
E V Chernyshova
EAE V Argunov
E V Argunov
AKA Khanina
A Khanina
DKDmitriy Karpenkov
Dmitriy Karpenkov
AEA El-Khouly
A El-Khouly
This work presents experimental investigation of the thermoelectric and structural characteristics of new double half Heusler alloys Hf2-xTixFeNiSb2 (x= 0, 0.15, 0.25 and 0.4). The studied samples were synthesized using different techniques of melt spinning, arc melting and spark plasma sintering. Crystal structure of the studied compounds was examined via x-ray diffraction (XRD). A face centered cubic structure was found to be the dominant crystallization phase. Homogeneity and relatively high density were obtained in the fabricated samples. Thermoelectric properties of the samples were studied over a temperature range from 300 to 800 K. Thermal conductivity was found to be significantly decreased with the Titanium (Ti) doping due to enhanced the phonon scattering. The highest value of the thermoelectric figure of merit was obtained for Hf1.75Ti0.25FeNiSb2 to be 0.28±0.014 at 800 K.

1 January 2020 in Journal of Radiation Research and Applied Sciences
Verified
Journal Article
Open access
MAM. S. Ali
M. S. Ali
GHG. S. Hassan
G. S. Hassan
AAA. M. Abdelmonem
A. M. Abdelmonem
SESamah K. Elshamndy
Samah K. Elshamndy
FEF. Elmasry
F. Elmasry
AYA. M. Yasser
A. M. Yasser
Through the introduced work a viable numerical scheme has been developed, using Numerov’s method, to study the energy spectra of mesons and hadronic interactions. Upon the implementation of the non-relativistic quark model and the Quantum Chromodynamics theory elements which describe the phenomenological interactions between the charm–anticharm quarks via two proposed potentials, our model accurately predicts the mass spectra of charmed quarkonium as an example of mesonic systems. It was found that our results agree well with the experimental charmonium masses that were published via the Particle Data Group (PDG). The proposed model has been tested for numerical instabilities and found that it works well for both proposed potentials. Although this model is suited to study the dynamics of charmonium interactions, we found that the results for one of the potentials are in better agreement with the published data. In addition, we predicted the mass spectrum of new charmed multiplets using the same previously mentioned potentials.

22 January 2019 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
PFPaolo Francescon
Paolo Francescon
WKWarren Kilby
Warren Kilby
NSNinfa Satariano
Ninfa Satariano
COChiara Orlandi
Chiara Orlandi
SESamah Kamel Elshamndy
Samah Kamel Elshamndy
Small field dosimetry correction factors are usually determined from calculations or measurements using one specific example of a treatment system. The sensitivity of the corrections to inter-unit variation is therefore not evaluated. We propose two methods for this evaluation that could be applied to any system. We use them to assess the variability in for the CyberKnife System caused by design changes between pre-M6 and M6 versions, and to the variability in and resulting from measured beam-data variations across 139 units. We also perform measurements to investigate the differences in reported for microchambers in a CyberKnife-specific study versus TRS-483. The results show that is smaller for the M6 version than pre-M6 versions by 0.4% for a Farmer chamber, and 0.1% for shorter chambers. The presence or absence of a lead filter within the treatment head had no significant impact on . The beam-data analysis showed inter-unit variations in of ±0.8% (2 s.d.) for Farmer chambers and ⩽ ±0.5% for shorter cavities (<10 mm) pre-M6, reducing to 0.4% and 0.2% respectively with M6. Inter-unit variations for microDiamond and microchambers were ⩽ ±1% at 5 mm field size, except for microchambers with axis perpendicular to the beam where this was > ±2%. Differences of up to 9% were confirmed between Output Factors measured using a microchamber and corrected using TRS-483 , and a consensus dataset for the same treatment unit determined using multiple detectors and Monte Carlo simulation. A set of practical recommendations for small field dosimetry with the CyberKnife System is derived from these results.

18 December 2014 in International Journal of Cancer Therapy and Oncology
Verified
Journal Article
Open access
PDF file
AAAmin Amin
Amin Amin
MKMohamed Kelaney
Mohamed Kelaney
SESamah K Elshamndy
Samah K Elshamndy
OGOsiris W. Guirguis
Osiris W. Guirguis
Purpose: Intensity modulated radiotherapy (IMRT) for cervical esophageal cancer is challenging. Although IMRT techniques using inverse planning algorithms are facilitating the treatment planning process, the irradiation dose to the normal tissues can be a critical issue. This study was performed to investigate the effect of beam numbers and their directions and local optimization on: (1) dose conformity and homogeneity to the planning target volume (PTV) and (2) dose to the organ at risks (OARs). Methods: Four upper esophageal cancer cases were randomly selected for this treatment planning study. Eight IMRT plans were generated for each case with the same dose-volume constraints but with different beam numbers and arrangements. Local optimization using regular structures drawn automatically around the PTV with margins from 0.5-1.5 cm was performed. IMRT plans were evaluated with respect to isodose distributions, dose-volume histograms (DVHs) parameters, homogeneity index (HI), and conformity index (CI). The statistical comparison between the types of plans was done using the One Way ANOVA test. Results: The results showed that IMRT using three or five beams was not sufficient to obtain good dose optimization. The seven field plans showed the best coverage for the PTV with tolerable doses for the OARs, and the beam orientation was very critical. Increasing beams (Bs) number from 7 to 13 did not show significant differences in the PTV coverage, while the mean lung dose was increased. The PTV coverage were 95.1, 95.1, 98.1, 97.3, 97.3, 97.3, 97.0, and 97.0% for 3Bs, 5Bs, 7Bs, 9Bs, 13Bs, 7Bs(30), 7Bs(60) (beam angles were changed from 0o to 30o and 60o), and 7Bs(R) (seven IMRT plans with ring), respectively. The mean heart dose did not exceed 0.36 Gy with p < 0.05. For lung doses, the best plan was the one with 9Bs which reduced lung volume doses V20Gy (%) and V30Gy (%), and reduced mean lung dose from 5.4 to 4.5 Gy with p < 0.05 for 7Bs(R) plans. IMRT improved the homogeneity indices (p > 0.05), yet conformity was better with 9Bs and 7Bs(R) IMRT plans with p < 0.05. Conclusion: Seven equispaced coplanar intensity-modulated beams with an addition of a ring structure can produce desirable dose distributions to the PTV. Moreover, dose-volume of exposed normal lung can be reduced with 9Bs and 7Bs(R) IMRT plans.