By improving its own gain performance, low light level imaging detection system based on microchannel plate(MCP) can collect weak signals that are difficult to observe by human eyes. However, when the detection system improves its own electronic gain, it will aggravate the image diffusion phenomenon collected by the detection system, which will seriously affect the imaging quality of the detection system. In order to improve the imaging quality of the detection system based on MCP under the experimental condition of high gain, in this paper, we present a high resolution imaging technique based on single photon signals experimentally. Under the condition of high gain, it is difficult for human eyes to recognize the target image acquired by the detection system based on MCP. However, the resolution of the target image can be improved to 28.57lp/mm through the reconstruction technology presentd in this paper.
In the laser systems for measurement and so on, like gyro; in its laser cavity or path, it makes use of the optical components which need very high performances, like low loss, low scatter, low reflection, low absorption and high transmittance. In this article, we design and manufacture the 632.8nm(He-Ne laser) low loss AR (LLAR) on crystal quartz, the results show this LLAR have the total loss is about 30ppm and have high uniformity, the fluctuations of the total loss mainly from the surface contamination and the inner defects of crystal material.
Indium tin oxide (ITO) thin film with SiO2 protective upper layer prepared by electron beam evaporation was annealed in air up to 300°C. Evolution of transmittance, resistance and surface morphology of this SiO2/ITO coating was studied. Transmittance in visible and near-infrared range both increased while absorption edge exhibited red shift after annealing. Resistance increased monotonously with rising annealing temperature, yet increments became smaller at temperatures above 270°C. Micron-defects were observed on the surface of SiO2/ITO coating after annealing. Enhancement of crystallinity of ITO layer at high temperatures was thought to be responsible for these morphology and resistance evolutions.
An explicit model from the matrix method is utilized to describe the measurement sensitivity of the photothermal detuning technique dependent on the polarization of the probe beam. Numerical results show that the optimal probe wavelengths and the slope of the main spectral band edges are different for both s- and p-polarized beams with the same incident angle. Compared with the random polarized probe beam at the larger incident angle, the measurement sensitivity can be improved approximately twice over with the p- and s-polarized probe beams under the optimal condition.