Marios Gourdouparis

Marios Gourdouparis

Auto-generated profile, based on publicly available information

Marios Gourdouparis

Imec, Eindhoven, AE, The Netherlands

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2024 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
YHYuming He
Yuming He
SVStan van der Ven
Stan van der Ven
HLHua-Peng Liaw
Hua-Peng Liaw
CSChengyao Shi
Chengyao Shi
PRPietro Russo
Pietro Russo
YLYao-Hong Liu
Yao-Hong Liu
Intracortical brain-computer interfaces offer superior spatial and temporal resolutions, but face challenges as the increasing number of recording channels introduces high amounts of data to be transferred. This requires power-hungry data serialization and telemetry, leading to potential tissue damage risks. To address this challenge, this paper introduces an event-based neural compressive telemetry (NCT) consisting of 8 channel-rotating Δ-ADCs, an event-driven serializer supporting a proposed ternary address event representation protocol, and an event-based LVDS driver. Leveraging a high sparsity of extracellular spikes and high spatial correlation of the high-density recordings, the proposed NCT achieves a compression ratio of >11.4×, while consumes only 1 µW per channel, which is 127× more efficient than state of the art. The NCT well preserves the spike waveform fidelity, and has a low normalized RMS error <23% even with a spike amplitude down to only 31 µV.

4 March 2024 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
CSChengyao Shi
Chengyao Shi
YHYuming He
Yuming He
MGMarios Gourdouparis
Marios Gourdouparis
GDGuido Dolmans
Guido Dolmans
YLYao-Hong Liu
Yao-Hong Liu
A near-field galvanic coupled transdural telemetry ASICs for intracortical brain-computer interfaces is presented. The proposed design features a two channels transmitter and three channels receiver (2TX-3RX) topology, which introduces spatial diversity to effectively mitigate misalignments (both lateral and rotational) between the brain and the skull and recovers the path loss by 13 dB when the RX is in the worst-case blind spot. This spatial diversity also allows the presented telemetry to support the spatial division multiplexing required for a high-capacity multi-implant distributed network. It achieves a signal-to-interference ratio of 12 dB, even with the adjacent interference node placed only 8 mm away from the desired link. While consuming only 0.33 mW for each channel, the presented RX achieves a wide bandwidth of 360 MHz and a low input referred noise of 13.21 nV/√ H z. The presented telemetry achieves a 270 Mbps data rate with a BER<10 -6 and an energy efficiency of 3.4 pJ/b and 3.7 pJ/b, respectively. The core footprint of the TX and RX modules is only 100 and 52 mm2, respectively, minimizing the invasiveness of the surgery. The proposed transdural telemetry system has been characterized ex-vivo with a 7-mm thick porcine tissue.

7 June 2021
Verified
Conference Paper
Closed access
MGMarios Gourdouparis
Marios Gourdouparis
Vassilis AlimisisVassilis Alimisis
Vassilis Alimisis
Christos DimasChristos Dimas
Christos Dimas
Paul SotiriadisPaul Sotiriadis
Paul Sotiriadis
A compact, ultra-low power (4nW), low supply voltage (0.6V) Gaussian-bump circuit architecture for Radial Basis Functions implementation is presented. It consists of only ten transistors, all operating in sub-threshold. The Gaussians center, height and width are independently and electronically controlled. The proposed architecture is used as a building block to construct a 2 – D Gaussian cascaded bump structure, demonstrating its dimensional scalability. Proper operation, sensitivity and accuracy are confirmed via theoretical analysis and simulation. The presented architectures were realized in TSMC 90nm CMOS process and were simulated using the Cadence IC Suite.