Yungang Wang

Yungang Wang

Auto-generated profile, based on publicly available information

Yungang Wang

National Satellite Meteorological Center China Meteorological Administration Beijing China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2022 in Journal of Geophysical Research: Space Physics
Verified
Journal Article
Closed access
JWJin Wang
Jin Wang
YSYang-Yi Sun
Yang-Yi Sun
TYTao Yu
Tao Yu
YWYungang Wang
Yungang Wang
MTMao Tian
Mao Tian
YQYifan Qi
Yifan Qi

18 March 2022 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
YWYungang Wang
Yungang Wang
LFLiping Fu
Liping Fu
FJFang Jiang
Fang Jiang
XHXiuqing Hu
Xiuqing Hu
CLChengbao Liu
Chengbao Liu
TMTian Mao
Tian Mao
The Ionospheric Photometer (IPM) is carried on the Feng Yun 3-D (FY3D) meteorological satellite, which allows for the measurement of far-ultraviolet (FUV) airglow radiation in the thermosphere. IPM is a compact and high-sensitivity nadir-viewing FUV remote sensing instrument. It monitors 135.6 nm emission in the nightside thermosphere and 135.6 nm and N2 Lyman–Birge–Hopfield (LBH) emissions in the dayside thermosphere that can be used to invert the peak electron density of the F2 layer (NmF2) at night and the O/N 2 ratio in the daytime, respectively. Preliminary observations show that the IPM could monitor the global structure of the equatorial ionization anomaly (EIA) structure around 02:00 LT using atomic oxygen (OI) 135.6 nm nightglow. It could also identify the reduction of O/N 2 in the high-latitude region during the geomagnetic storm of 26 August 2018. The IPM-derived NmF2 agrees well with that observed by four ionosonde stations along 120∘ E with a standard deviation of 26.67 %. Initial results demonstrate that the performance of IPM meets the design requirements and therefore can be used to study the thermosphere and ionosphere in the future.

9 July 2024 in Journal of Geophysical Research: Space Physics
Verified
Journal Article
Closed access
GCGang Chen
Gang Chen
XCXuesi Cai
Xuesi Cai
SZShaodong Zhang
Shaodong Zhang
WGWanlin Gong
Wanlin Gong
GYGuotao YANG
Guotao YANG
PHPengfei Hu
Pengfei Hu

30 September 2021 in EGUsphere
Verified
Preprint
Open access
PDF file
YWYungang Wang
Yungang Wang
LFLiping Fu
Liping Fu
FJFang Jiang
Fang Jiang
XHXiuqing Hu
Xiuqing Hu
CLChengbao Liu
Chengbao Liu
TMTian Mao
Tian Mao
The Ionospheric Photometer (IPM) is carried on the Feng Yun 3D (FY3D) meteorological satellite, which allows for the measurement of far-ultraviolet (FUV) airglow radiation in the thermosphere. IPM is a compact and high-sensitivity nadir-viewing FUV remote sensing instrument. It monitors 135.6 nm emission in the night-side thermosphere and 135.6 nm and N2 LBH emissions in the day-side thermosphere that can be used to invert the peak electron density of the F2 layer (NmF2) at night and O / N2 ratio in the daytime, respectively. Preliminary observations show that the IPM could monitor the global structure of the equatorial ionization anomaly (EIA) structure around 2:00 local time using OI 135.6 nm nightglow properly. It could also identify the reduction of O / N2 in the high-latitude region during the geomagnetic storm of Aug. 26, 2018. The IPM derived NmF2 accords well with that observed by 4 ionosonde stations along 120° E with a standard deviation of 26.67 %. Initial results demonstrate that the performance of IPM meets the designed requirement and therefore can be used to study the thermosphere and ionosphere in the future.

30 October 2021
Verified
Other
Open access
PDF file
YWYungang Wang
Yungang Wang
LFLiping Fu
Liping Fu
FJFang Jiang
Fang Jiang
XHXiuqing Hu
Xiuqing Hu
CLChengbao Liu
Chengbao Liu
TMTian Mao
Tian Mao
The Ionospheric Photometer (IPM) is carried on the Feng Yun 3D (FY3D) meteorological satellite, which allows for the measurement of far-ultraviolet (FUV) airglow radiation in the thermosphere. IPM is a compact and high-sensitivity nadir-viewing FUV remote sensing instrument. It monitors 135.6 nm emission in the night-side thermosphere and 135.6 nm and N2 LBH emissions in the day-side thermosphere that can be used to invert the peak electron density of the F2 layer (NmF2) at night and O / N2 ratio in the daytime, respectively. Preliminary observations show that the IPM could monitor the global structure of the equatorial ionization anomaly (EIA) structure around 2:00 local time using OI 135.6 nm nightglow properly. It could also identify the reduction of O / N2 in the high-latitude region during the geomagnetic storm of Aug. 26, 2018. The IPM derived NmF2 accords well with that observed by 4 ionosonde stations along 120° E with a standard deviation of 26.67 %. Initial results demonstrate that the performance of IPM meets the designed requirement and therefore can be used to study the thermosphere and ionosphere in the future.

28 October 2024
Verified
Preprint
Open access
PDF file
YMYuntao Mao
Yuntao Mao
ZCZiwei Chen
Ziwei Chen
YLYanfeng Li
Yanfeng Li
HCHoujin Chen
Houjin Chen
TMTian Mao
Tian Mao
YWYungang Wang
Yungang Wang
The ionosphere profoundly impacts our daily lives, with ionograms serving as essential tools for assessing its state. However, due to the ionosphere’s unstable nature, these ionograms are often complex, highly variable, and plagued by various forms of noise and signal interference. While existing methods for ionogram analysis have focused on technical and model innovations, they have largely ignored the importance of improving the quality of the ionograms themselves. The basic principle ”Quality in, quality out” aptly describes this situation: the quality of the input ionograms fundamentally limits the best performance of any analysis. By enhancing data quality, we can boost the potential of analytic methods. To this end, we define ionogram reconstruction as a process that includes denoising, enhancing weak signals, and connecting interrupted signals. We present a low-cost and high-quality ionogram reconstruction pipeline, meticulously tailored in its training strategies, model architecture, and loss functions to align with the characteristics of ionograms. Key innovations include the use of semi-supervised learning to reduce manual labeling costs, the invention of the Tanh Valve and External Residual Connection mechanisms to speed up model convergence, and the creation of a loss function with a tracking mechanism to shift model focus. Experimental results confirm that our pipeline is exceptionally well-suited for ionogram reconstruction, with every design choice proving indispensable.