Xiaoqiu Tao

Xiaoqiu Tao

Auto-generated profile, based on publicly available information

Xiaoqiu Tao

Sichuan tobacco quality supervision and testing station , Chengdu, Sichuan 610041 P.R. China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2021 in Korean Journal of Chemical Engineering
Verified
Journal Article
Closed access
PDF file
Yubin WangYubin Wang
Yubin Wang
XTXiaoqiu Tao
Xiaoqiu Tao
JLJun Li
Jun Li
SZSiqi Zhang
Siqi Zhang
YJYang Jin
Yang Jin
MCMing Chen
Ming Chen

15 January 2021 in Journal of Analytical Methods in Chemistry
Verified
Journal Article
Open access
PDF file
巍熊巍 熊
巍 熊
LWLing Wang
Ling Wang
HZHaiyan Zhang
Haiyan Zhang
XTXiaoqiu Tao
Xiaoqiu Tao
XJXuehua Jiang
Xuehua Jiang
WXWenwen Xu
Wenwen Xu
A sensitive and selective ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS-MS) method for the determination of apremilast in beagle dog plasma has been developed and successfully validated in the current study. Clopidogrel was employed as an internal standard (IS), and liquid-liquid extraction by tert-butylmethyl ether was used for sample preparation. Chromatographic separation was achieved on a UPLC BEH Shield RP18 column (50 mm × 2.1 mm, 1.7 μm) with 5 mM ammonium formate water and 5 mM ammonium formate methanol as the mobile phase with gradient elution. Calibration plots were linear in the range of 2–3000 ng/mL for apremilast in beagle dog plasma. Mean recoveries of apremilast in beagle dogs plasma ranged from 87.4% to 97.4%. The intrarun and interrun precision was less than 6% and 9%, respectively, with the accuracy between 92.4% and 101.1%. The method has also been successfully applied in the pharmacokinetics study of apremilast. The mean t1/2Z was 5.41 h for 30 mg·day−1 for beagle dogs after oral administration. The AUC0-t increased linearly from 3.51 to 1802.13 after administration of single doses.

1 October 2021 in Journal of Chromatographic Science
Verified
Journal Article
Closed access
PDF file
巍熊巍 熊
巍 熊
XTXiaoqiu Tao
Xiaoqiu Tao
HZHaiyan Zhang
Haiyan Zhang
MHMei Huang
Mei Huang
JSJimin Shao
Jimin Shao
A novel method has been developed for the simultaneous determination of multiclass pesticide residues in tobacco and cigarette smoke, using a modified QuEChERS (quick, easy, cheap, effective, rugged and safe) procedure and ultra-performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS). Cigarette mainstream smoke particulate was collected on a Cambridge filter pad. Pesticide residues was extracted with an aqueous solution, back extracted into acetonitrile after freezing, purified by dispersive solid phase extraction with primary-secondary amine adsorbents and analyzed by UPLC–MS/MS. The obtained mean recoveries of 16 pesticides commonly used on tobacco at three fortification levels (5.9, 94.1 and 352.9 ng g−1) ranged from 69.3 to 115.9% with relative standard deviations between 2.4 and 11.3%. The limits of detection ranged from 0.14 to 13.28 ng g−1. Finally, the proposed method was applied to study the pesticide smoke transfer ratio in 2 cigarettes with pesticide standard spiked and 51 cigarettes with one or more pesticide residues. The transfer ratio of pesticides residue in tobacco into the smoke might be much less than that from artificially spiked tobacco (<25%) with spiking levels varied from 1.88 to 9.41 μg g−1. The transfer ratio of pesticide from artificially spiked tobacco into cigarette mainstream smoke was from 0.0 to 56.5%, and pesticide residues from tobacco into cigarette smoke were from 0.0 to 26.1% using the ISO smoking method (ISO 3308 2012).