Athletes vary in hydration status due to ongoing training regimes, diet demands, and extreme exertion. With water being one of the largest body composition compartments, its variation can cause misinterpretation of body composition assessments meant to monitor strength and training progress. In this study, we asked what accessible body composition approach could best quantify body composition in athletes with a variety of hydration levels. The Da Kine Study recruited collegiate and intramural athletes to undergo a variety of body composition assessments including air-displacement plethysmography (ADP), deuterium-oxide dilution (D2O), dual-energy X-ray absorptiometry (DXA), underwater-weighing (UWW), 3D-optical (3DO) imaging, and bioelectrical impedance (BIA). Each of these methods generated 2- or 3-compartment body composition estimates of fat mass (FM) and fat-free mass (FFM) and was compared to equivalent measures of the criterion 6-compartment model (6CM) that accounts for variance in hydration. Body composition by each method was used to predict abdominal and thigh strength, assessed by isokinetic/isometric dynamometry. In total, 70 (35 female) athletes with a mean age of 21.8 ± 4.2 years were recruited. Percent hydration (Body Water6CM/FFM6CM) had substantial variation in both males (63-73 %) and females (58-78 %). ADP and DXA FM and FF M had moderate to substantial agreement with the 6C model (Lin's Concordance Coefficient [CCC] = 0.90-0.95) whereas the other measures had lesser agreement (CCC <0.90) with one exception of 3DO FFM in females (CCC = 0.91). All measures of FFM produced excellent precision with %CV < 1.0 %. However, FM measures in general had worse precision (% CV < 2.0 %). Increasing quartiles (significant p < 0.001 trend) of 6CM FFM resulted in increasing strength measures in males and females. Moreover, the stronger the agreement between the alternative methods to the 6CM, the more robust their correlation with strength, irrespective of hydration status. The criterion 6CM showed the best association to strength regardless of the hydration status of the athletes for both males and females. Simpler methods showed high precision for both FM and FFM and those with the strongest agreement to the 6CM had the highest strength associations. This study compared various body composition analysis methods in 70 athletes with varying states of hydration to the criterion 6-compartment model and assessed their relationship to muscle strength. The results showed that accurate and precise estimates of body composition can be determined in athletes, and a more accurate body composition measurement produces better strength estimates. The best laboratory-based techniques were air displacement plethysmography and dual-energy x-ray absorptiometry, while the commercial methods had moderate-poor agreement. Prioritizing accurate body composition assessment ensures better strength estimates in athletes.
Muscle mass and strength are crucial for physiological function and performance in athletes, playing a significant role in maintaining health and optimal athletic performance. Skeletal muscle, which constitutes the majority of lean soft tissue (LST) and appendicular lean soft tissue (ALST) when measured by dual-energy X-ray absorptiometry (DXA), represents a commonly used surrogate for strength. Research has investigated alternative measures of body composition, such as the assessment of ALST through bioelectrical impedance analysis (BIA) and the determination of whole-body muscle mass from creatine pool size using the deuterated creatine (D3Cr) dilution method, for their associations to strength. While the relationship between body composition measures and strength has been studied in older adults, this relationship remains unexplored in athletic populations. This study examined muscle body composition measures using DXA, D3Cr, and BIA and their association with strength in a sample of collegiate athletes. The study enrolled 80 collegiate athletes (40 females) of differing sports disciplines who consumed a 60 mg dose of D3Cr and completed DXA and BIA measures in addition to trunk and leg strength tests. Analysis was sex-stratified using Pearson’s correlations, linear regression, and quartile p trend significance. With an average participant age of 21.8 years, whole-body DXA correlations to muscle strength surpassed height- or mass-normalized values. This trend was especially pronounced in trunk strength’s relationship with body composition over leg strength, across measurement methods. While DXA LST values were higher than BIA and D3Cr in predicting strength, the values did not differ significantly. Adjustments for age, BMI, and BIA variables didn’t enhance this association. A significant trend between DXA LST and all strength measures underscored the equal relevance of DXA and D3Cr muscle mass to strength, favoring whole-body over regional assessments. This calls for future research on muscle mass’s effects on LST and functional outcomes in broader groups, highlighting the importance of comprehensive body composition analysis in athletic performance studies.