Luis Carlos Álvarez

Luis Carlos Álvarez

Auto-generated profile, based on publicly available information

Luis Carlos Álvarez

Univ. Nacional Autónoma de México (Mexico)

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2012
Verified
Conference Paper
Closed access
PDF file
NBNat Butler
Nat Butler
CKChris Klein
Chris Klein
OFOri Fox
Ori Fox
GLGennadiy Lotkin
Gennadiy Lotkin
JBJosh Bloom
Josh Bloom
LSLeroy M. Sparr
Leroy M. Sparr

15 October 2013 in Applied Optics
Verified
Journal Article
Closed access
PDF file
JFJorge Fuentes-Fernandez
Jorge Fuentes-Fernandez
SCSalvador Cuevas
Salvador Cuevas
LÁLuis C. Álvarez-Nuñez
Luis C. Álvarez-Nuñez
AWAlan Watson
Alan Watson
Curvature wavefront sensors (WFSs), which obtain the wavefront aberrations from two defocused intensity images at each side of the pupil plane, have shown to be highly efficient for astronomical applications. We propose here an alternative defocusing mechanism for curvature sensors, based on an electrowetting-based variable focus liquid lens. Typically, the sampling rates of a WFS for active optics are of the order of 0.01 Hz, and the focus modulation can be done by simply moving the detector back and forth. On the other hand, adaptive optics may require speeds of up to several hundred hertz, and the modulation is then done by using a fast vibrating membrane mirror. We believe variable focus liquid lenses may be able to perform this focus modulation, reducing the overall size of the system and without the need of extra moving parts. We have done a full characterization of the Varioptic Arctic 416 liquid lens, and we have evaluated its potential performance in different curvature configurations.

9 August 2016
Verified
Conference Paper
Closed access
PDF file
AWAlan M. Watson
Alan M. Watson
SCSalvador Cuevas Cardona
Salvador Cuevas Cardona
LNLuis C. Alvarez Nuñez
Luis C. Alvarez Nuñez
FÁFernando Ángeles
Fernando Ángeles
RBRosa L. Becerra-Godínez
Rosa L. Becerra-Godínez
STSilvio J. Tinoco
Silvio J. Tinoco
COATLI will provide 0.3 arcsec FWHM images from 550 to 900 nm over a large fraction of the sky. It consists of a robotic 50-cm telescope with a diffraction-limited fast-guiding imager. Since the telescope is small, fast guiding will provide diffraction-limited image quality over a field of at least 1 arcmin and with coverage of a large fraction of the sky, even in relatively poor seeing. The COATLI telescope will be installed at the at the Observatorio Astron\'omico Nacional in Sierra San Pedro M\'artir, M\'exico, during 2016 and the diffraction-limited imager will follow in 2017.Comment: To appear in the proceedings of SPIE conference 9908 "Ground-based and Airborne Instrumentation for Astronomy VI". 9 page

9 August 2016
Verified
Conference Paper
Closed access
PDF file
AWAlan M. Watson
Alan M. Watson
JAJosé A. Acosta-Pulido
José A. Acosta-Pulido
LÁLuis C. Álvarez-Núñez
Luis C. Álvarez-Núñez
VBVicente Bringas-Rico
Vicente Bringas-Rico
NCNicolás Cardiel
Nicolás Cardiel
FBFrancisco Váldez Berriozabal
Francisco Váldez Berriozabal
FRIDA is a diffraction-limited imager and integral-field spectrometer that is being built for the adaptive-optics focus of the Gran Telescopio Canarias. In imaging mode FRIDA will provide scales of 0.010, 0.020 and 0.040 arcsec/pixel and in IFS mode spectral resolutions of 1500, 4000 and 30,000. FRIDA is starting systems integration and is scheduled to complete fully integrated system tests at the laboratory by the end of 2017 and to be delivered to GTC shortly thereafter. In this contribution we present a summary of its design, fabrication, current status and potential scientific applications.Comment: To appear in the proceedings of SPIE conference 9908 "Ground-based and Airborne Instrumentation for Astronomy VI". 8 page

4 August 2014
Verified
Conference Paper
Closed access
PDF file
BSBe. Sánchez
Be. Sánchez
CKC. Keiman
C. Keiman
CEC. Espejo
C. Espejo
SCS. Cuevas
S. Cuevas
LÁL. C. Álvarez
L. C. Álvarez
JUJ. Uribe
J. Uribe
FRIDA (inFRared Imager and Dissector for the Adaptive optics system of the Gran Telescopio Canarias (GTC)) is designed as a diffraction limited instrument that will offer broad and narrow band imaging and integral field spectroscopy capabilities with low, intermediate and high (R ~ 30,000) spectral resolutions, to operate in the wavelength range 0.9 – 2.5 μm. The integral field unit is based on a monolithic image slicer and the imaging and IFS observing modes will use the same Teledyne 2Kx2K detector. FRIDA will be based on a Nasmyth B of GTC, behind the adaptive optics (AO) system. The key scientific objectives of the instrument include studies of solar system bodies, low mass objects, circumstellar outflow phenomena in advanced stages of stellar evolution, active galactic nuclei high redshift galaxies, including resolved stellar populations, semidetached binary systems, young stellar objects and star forming environments. FRIDA subsystems are presently being manufactured and tested. In this paper we present the challenges to perform the verification of some critical specifications of a cryogenic and diffraction limited NIR instrument as FRIDA. FRIDA is a collaborative project between the main GTC partners, namely, Spain, México and Florida.

9 August 2016
Verified
Conference Paper
Closed access
PDF file
SCSalvador Cuevas
Salvador Cuevas
RLRosalia Langarica
Rosalia Langarica
AWAlan M. Watson
Alan M. Watson
JFJorge Fuentes-Fernández
Jorge Fuentes-Fernández
FÁFernando Ángeles
Fernando Ángeles
STSilvio J. Tinoco
Silvio J. Tinoco