Background. The main goal of our study was to assess the volume of dentin removed and transportation in root canals using ProTaper Universal (PTU), ProTaper Gold (PTG) and One-Curve (OC). Ni-Ti rotary instruments in extracted human teeth using by micro-CT. Methods: Thirty human upper 1st premolar teeth with two separate root canals and sturdy, mature root tips were used in the present study. Specimens were decoronated and root length was standardized for micro CT scanning before root canal preparation done. The teeth were randomly separated into three categories (n = 10) according to the rotary NiTi system used for canal instrumentation, i.e., PTU (Dentsply, Maillefer), PTG (Dentsply, Maillefer), and OC (Micro-Mega SA). After root canal preparation, samples were scanned again on micro-CT by the same scanning parameters. Surface area, canal volume, structure model index (SMI), percentage of uninstrumented area and transportation parameters were obtained for each sample before and after micro-CT analyse. Results: No significant differences between the PTG and PTU in terms of the total volume of removed dentin, surface area and percentage of uninstrumented areas were found. However, regarding to parameters above, OC showed a lower efficacy than PTG and PTU in coronal section. Regarding canal transportation, PTG and OC showed lower mean transportation values at all levels. Conclusion: This paper demonstrated the root canal shaping abilities of the PTU, PTG, and OC NiTi file systems. The PTG and OC systems were associated less canal transportation and a better ability to preserve dentinal walls than PTU. There was no significance different between all rotary file systems for SMI values however, PTU and PTG showed greater canal volume and surface area change than OC file systems in coronal section.
18 January 2024 in Community Dentistry and Oral Epidemiology
Objective. To evaluate the voids in root canal treatment of deciduous molar canals using three obturating materials and two obturation systems using micro‐CT. Study Design. Thirty freshly extracted deciduous molars were used in this study. The specimens were instrumented using a ProTaper Universal rotary instrument and randomly assigned into six groups (n = 5). Mesiobuccal root canals were obturated using Ca(OH)2 and iodoform‐Ca(OH)2 and ZOE cement. The materials were applied straight from the syringe up to the 2 mm coronal level of the apex. Subsequently, the Lentulo spiral and ultrasonic activation with endoactivator were used for obturation. All samples were scanned by micro‐CT with 9.1 μm isotropic voxel resolution. The voids in cross‐sectional images and 3D volumes of voids were measured. Differences among materials were statically evaluated (p < 0.05). Results. All study groups showed voids. Ca(OH)2 and iodoform‐Ca(OH)2 with ultrasonic activation produced fewer voids whereas the ZOE groups showed higher voids with statistical significance (p < 0.05). Conclusions. Ca(OH)2 and iodoform‐Ca(OH)2 with ultrasonic activation decrease void formation. Further studies should be done with other obturation techniques and materials for deciduous tooth root canal management.
We evaluated and compared the effects of different NiTi rotary systems – ProTaper Next and New One Shape – on the volume of dentin removed, canal transportation, and canal curvature in extracted human teeth using CBCT scanning with different voxel sizes. Fifty extracted human maxillary first molars with mesiobuccal canal curvature (25-35°) were used. Specimens were instrumented with the ProTaper Next or New One Shape. Pre- and post-instrumentation scans were performed to compare transportation at the levels of 2, 5, and 8 mm and volumes with two different voxel sizes (0.125-and 0.100-mm3) using 3D CBCT images. This study evaluated and compare the volume of dentin removed, canal transportation, and canal curvature. Differences according to instrumentation and voxel sizes were assessed using the Mann–Whitney U-test and the Wilcoxon signed-rank test. Significant differences were found between apical and coronal levels for both systems (p < 0.05) in canal transportation. In comparing the systems, similar values were found at each level, without significant difference (p > 0.05) in terms of canal curvature and volume. Voxel sizes did not affect the measurements on canal volume, curvature or transportation; no significant difference was found between the 0.100- and 0.125-mm3 voxel sizes (p > 0.05). Both instrumentation systems produced similar canal transportation and volume changes. The two voxel resolutions also showed similar results, however a 0.125-mm3 voxel size can be recommend for a flat panel CBCT scanner with lower exposure dose.