Jon K. Moon

Jon K. Moon

Auto-generated profile, based on publicly available information

Jon K. Moon

MEI Research, Ltd. Edina, MN United States

Research Focus & Metrics

Academic Career Length

37Years (1990-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 1999 in The American Journal of Clinical Nutrition
Verified
Journal Article
Open access
PDF file
NBNancy F Butte
Nancy F Butte
JHJudy M Hopkinson
Judy M Hopkinson
NMNitesh Mehta
Nitesh Mehta
JMJon K Moon
Jon K Moon
ESE O'Brian Smith
E O'Brian Smith
Background: Metabolic adjustments occur during pregnancy and lactation to support fetal growth and milk synthesis; however, the effect of body composition and hormonal milieu on these changes is poorly understood. Objective: We hypothesized that energy metabolism changes during pregnancy and lactation to support fetal growth and milk synthesis, and that body composition and hormonal milieu influence these alterations. Design: We measured energy expenditure, body composition, and hormone, metabolite, and catecholamine concentrations in 76 women (40 lactating, 36 nonlactating) at 37 wk gestation and 3 and 6 mo postpartum. Total energy expenditure (TEE), basal metabolic rate (BMR), sleeping metabolic rate (SMR), and minimal SMR (MSMR) were measured with room calorimetry. Fat-free mass (FFM) and fat mass were estimated with a 4-component model. Results: TEE, BMR, SMR, and MSMR were 15–26% higher during pregnancy than postpartum after being adjusted for FFM, fat mass, and energy balance. TEE, SMR, and MSMR were higher in lactating than in nonlactating women. Fasting serum insulin, insulin-like growth factor I, fatty acids, and leptin, and 24-h urinary free norepinephrine, epinephrine, and dopamine correlated positively with TEE, BMR, SMR, and MSMR. In nonlactating women, the respiratory quotient decreased over time, carbohydrate oxidation decreased, and fat oxidation increased. Substrate utilization was not influenced by body composition, fasting serum hormones, or 24-h urinary catecholamines. Conclusions: These results indicate increased energy expenditure and preferential use of carbohydrates during pregnancy and lactation. Elevated respiratory quotient and carbohydrate utilization during pregnancy continue during lactation, consistent with preferential use of glucose by the fetus and mammary gland.

25 June 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
DBDale S. Bond
Dale S. Bond
JTJ. Graham Thomas
J. Graham Thomas
HRHollie Raynor
Hollie Raynor
JMJon Moon
Jon Moon
JSJared Sieling
Jared Sieling
RWRena R. Wing
Rena R. Wing
Excessive sedentary time (SED) has been linked to obesity and other adverse health outcomes. However, few sedentary-reducing interventions exist and none have utilized smartphones to automate behavioral strategies to decrease SED. We tested a smartphone-based intervention to monitor and decrease SED in overweight/obese individuals, and compared 3 approaches to prompting physical activity (PA) breaks and delivering feedback on SED. Participants [N = 30; Age = 47.5(13.5) years; 83% female; Body Mass Index (BMI) = 36.2(7.5) kg/m2] wore the SenseWear Mini Armband (SWA) to objectively measure SED for 7 days at baseline. Participants were then presented with 3 smartphone-based PA break conditions in counterbalanced order: (1) 3-min break after 30 SED min; (2) 6-min break after 60 SED min; and (3) 12-min break after 120 SED min. Participants followed each condition for 7 days and wore the SWA throughout. All PA break conditions yielded significant decreases in SED and increases in light (LPA) and moderate-to-vigorous PA (MVPA) (p<0.005). Average % SED at baseline (72.2%) decreased by 5.9%, 5.6%, and 3.3% [i.e. by mean (95% CI) −47.2(−66.3, −28.2), −44.5(−65.2, −23.8), and −26.2(−40.7, −11.6) min/d] in the 3-, 6-, and 12-min conditions, respectively. Conversely, % LPA increased from 22.8% to 26.7%, 26.7%, and 24.7% [i.e. by 31.0(15.8, 46.2), 31.0(13.6, 48.4), and 15.3(3.9, 26.8) min/d], and % MVPA increased from 5.0% to 7.0%, 6.7%, and 6.3% (i.e. by 16.2(8.5, 24.0), 13.5(6.3, 20.6), and 10.8(4.2, 17.5) min/d] in the 3-, 6-, and 12-min conditions, respectively. Planned pairwise comparisons revealed the 3-min condition was superior to the 12-min condition in decreasing SED and increasing LPA (p<0.05). The smartphone-based intervention significantly reduced SED. Prompting frequent short activity breaks may be the most effective way to decrease SED and increase PA in overweight/obese individuals. Future investigations should determine whether these SED reductions can be maintained long-term. ClinicalTrials.gov NCT01688804

13 March 2015 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
Shanon CaspersonShanon Casperson
Shanon Casperson
JSJared Sieling
Jared Sieling
JMJon Moon
Jon Moon
LJLuAnn Johnson
LuAnn Johnson
JRJames Roemmich
James Roemmich
LWLeah D Whigham
Leah D Whigham
Mobile and tablet apps, ubiquitous and pervasive computing, wearable computing and domotics for health.

1 February 1995 in The Journal of Nutrition
Verified
Journal Article
Closed access
JMJon K. Moon
Jon K. Moon
FVFiroz A. Vohra
Firoz A. Vohra
OJOmar S. Valerio Jimenez
Omar S. Valerio Jimenez
MPMaurice R. Puyau
Maurice R. Puyau
NBNancy F. Butte
Nancy F. Butte
Large room calorimeters are capable of rapid measurements that are usually made in hoods or small rooms. We evaluated the performance gains of four calorimeters constructed with modern control systems, sample gas preparation and data processing. Calibration of the calorimeters and instruments was performed in place, with traceability to international standards. Performance was evaluated by infusion of N2-CO2 gas and 243 24-h studies of individuals. Our subjects included children weighing 20 kg and adults engaged in heavy exercise. Errors for 24-h infusion measurements (n = 23) were -0.34 +/- 1.24% for oxygen consumption rate and 0.11 +/- 0.98% for carbon dioxide production rate. Calorimeter 90% response times were 2 to 6 min over a range of oxygen consumption rates from 100 to > 4000 mL/min. Closed-loop control of supply and exhaust air flows provided consistent 24-h mean CO2 levels (0.39 +/- 0.015%) and pressures (13.2 +/- 4.4 Pa). Room calorimeters operated with closed-loop control can be used for accurate measurement of energy expenditure rate dynamics for a wide range of individuals.

28 June 2008 in Insect Molecular Biology
Verified
Journal Article
Closed access
PDF file
YKY. D. Koo
Y. D. Koo
JAJ.‐E. Ahn
J.‐E. Ahn
RSR. A. Salzman
R. A. Salzman
JMJ. Moon
J. Moon
YCY. H. Chi
Y. H. Chi
KZKeyan Zhu-Salzman
Keyan Zhu-Salzman

1 October 1996 in Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
JMJon K. Moon
Jon K. Moon
NBNancy F. Butte
Nancy F. Butte
Moon, Jon K., and Nancy F. Butte. Combined heart rate and activity improve estimates of oxygen consumption and carbon dioxide production rates. J. Appl. Physiol.81(4): 1754–1761, 1996.—Oxygen consumption (V˙o2) and carbon dioxide production (V˙co2) rates were measured by electronically recording heart rate (HR) and physical activity (PA). Mean daily V˙o2andV˙co2measurements by HR and PA were validated in adults ( n = 10 women and 10 men) with room calorimeters. Thirteen linear and nonlinear functions of HR alone and HR combined with PA were tested as models of 24-h V˙o2andV˙co2. Mean sleepV˙o2andV˙co2were similar to basal metabolic rates and were accurately estimated from HR alone [respective mean errors were −0.2 ± 0.8 (SD) and −0.4 ± 0.6%]. The range of prediction errors for 24-h V˙o2andV˙co2was smallest for a model that used PA to assign HR for each minute to separate active and inactive curves (V˙o2, −3.3 ± 3.5%; V˙co2, −4.6 ± 3%). There were no significant correlations betweenV˙o2orV˙co2errors and subject age, weight, fat mass, ratio of daily to basal energy expenditure rate, or fitness. V˙o2,V˙co2, and energy expenditure recorded for 3 free-living days were 5.6 ± 0.9 ml ⋅ min−1⋅ kg−1, 4.7 ± 0.8 ml ⋅ min−1⋅ kg−1, and 7.8 ± 1.6 kJ/min, respectively. Combined HR and PA measured 24-h V˙o2andV˙co2with a precision similar to alternative methods.