Osita Uchechukwu Omeje

Osita Uchechukwu Omeje

Auto-generated profile, based on publicly available information

Osita Uchechukwu Omeje

Department of Electrical & Electronics Engineering, University of Lagos, Yaba, Nigeria

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 June 2025 in Journal of King Saud University – Engineering Sciences
Verified
Journal Article
Open access
PDF file
OOOsita U. Omeje
Osita U. Omeje
OBOlanrewaju M. Bankole
Olanrewaju M. Bankole
DODANIEL ESENE OKOJIE
DANIEL ESENE OKOJIE
CECandidus U. Eya
Candidus U. Eya
Accurate fault location in transmission lines remains a critical challenge for modern power systems, particularly as networks become increasingly complex with the integration of renewable energy sources and smart grid technologies. Traditional fault location methods often need help with high-impedance faults, non-homogeneous line parameters, and dynamic system conditions, leading to extended outage durations and reduced system reliability. This study addresses these challenges by developing an enhanced fault location method that combines conventional electromagnetic principles with advanced machine learning techniques. The methodology employs an approach that integrates modified impedance-based calculations with convolutional neural networks and machine learning regression. The method was validated using a modified IEEE 39-bus test system through simulations, incorporating several fault scenarios and system conditions. Testing utilised synchronised measurements from both transmission line ends, with data captured at 4096 samples per second. Results demonstrate significant improvements over existing techniques, achieving a 99.1% fault detection rate, 98.2% classification accuracy, and 1.2% mean absolute percentage error in location estimation. The method showed particular strength in challenging scenarios, reducing errors by 79.4% for high-impedance faults and maintaining accuracy under variable renewable generation conditions. The proposed method advances power system protection by providing a robust, adaptive solution suitable for modern grid requirements. Its conventional instrumentation implementation facilitates practical adoption, offering improved reliability and reduced outage durations in real-world applications.

20 July 2026 in Electrica
Verified
Journal Article
Open access
PDF file
OOOsita Uchechukwu Omeje
Osita Uchechukwu Omeje
AEAnthony Onyebuchi Ejimofor
Anthony Onyebuchi Ejimofor
DODANIEL ESENE OKOJIE
DANIEL ESENE OKOJIE
The integration of the Internet of Things (IoT) into power quality monitoring (PQM) has modernized electrical systems by enabling real-time acquisition and analysis of PQ data. While these advances improve monitoring efficiency and responsiveness, they introduce challenges related to scalability, cybersecurity, interoperability, and the lack of standardized protocols. This paper presents a structured review of IoT-based PQM technologies, with an emphasis on system architectures, machine learning techniques, and blockchain-based security approaches. The evolution of PQM systems is outlined, and recent real-world implementations are examined to highlight practical strengths and limitations. Research gaps are identified, and recommendations are provided to guide future development. Overall, the paper synthesizes the state of the field and offers actionable insights for researchers, utilities, and policymakers seeking reliable, secure, and adaptable PQM infrastructures. Cite this article as: O. U. Omeje, A. O. Ejimofor and D. E. Okojie, “Internet of things–based power quality monitoring systems: technologies, challenges, and future directions—A review,” Electrica, 26, 0183, 2026, doi:10.5152/electrica.2026.25183.

3 June 2026 in International Journal of Energy and Power Engineering
Verified
Journal Article
Closed access
OOOsita Omeje
Osita Omeje
GOGoziechi Orakwe
Goziechi Orakwe
LILinus Idoko
Linus Idoko
The energy industry faces a variety of challenges as a result of the growing demand for electricity. The emphasis is shifting to optimizing energy use in residential settings so as to achieve sustainable alternatives. The escalating demand for sustainable energy practices in residential environments gives rise to innovative approaches to home energy management. In order to significantly reduce home energy use and contribute to a more sustainable future, this paper proposes an optimization model for home energy management that combines Model Predictive Control (MPC) with Demand Response (DR) strategy to reduce energy consumption. The study used several types of data, such as the hourly load demand of a house and solar irradiance data. Load demand profile, derived from historical electricity usage records, provided hourly energy consumption over a 24-hour period, serving as essential input for predicting future energy needs using the MPC algorithm. Solar irradiance data and PV system specifications were utilized to model the power generated by PV panels, while information about the battery energy storage system, including its capacity, efficiency, and state of charge (SOC) limits, was essential for modelling the behavior of the battery in storing and discharging energy. The model encompasses mathematical models and optimization tools for the efficient usage of photovoltaic (PV) panels, battery energy storage systems (BESS), and grid power. With the aid of MATLAB/Simulink simulations, the study demonstrated that MPC effectively predicts energy demand and allocates power sources effectively, achieving a 41% reduction in energy costs compared to grid-only scenarios. Considering the results obtained, this paper suggests areas of further research work, such as integrating dynamic pricing models in countries like Nigeria and exploring hybrid renewable energy systems. This will build on the findings obtained in this work and further improve household energy efficiency and sustainability.

2 June 2026 in American Journal of Electrical Power and Energy Systems
Verified
Journal Article
Closed access
OOOsita Omeje
Osita Omeje
FEFavour Edwards
Favour Edwards
LILinus Idoko
Linus Idoko
For power systems to be stable and reliable, an accurate prediction of electrical load demand is crucial. Electric utilities rely on short-term load forecasting to effectively manage the generation, transmission, and distribution of power to satisfy customer demand. Artificial Neuro-Fuzzy Inference System (ANFIS) is utilized in this work for short-term load forecasting due to its propensity to manage non-linear relationships and uncertainty. ANFIS method has been used in the past for short-term load forecasting, there are certain conditions and issues that need to be resolved. Data normalization, choice of optimization technique, and choice of membership function can greatly influence short-term load forecast using ANFIS. Thus, this paper explored the different choices available and recommended the best choices based on the results obtained. Hourly electrical load data from 24 th November 2021 to 4 th January 2022, sourced from University of Lagos Power Station, and relevant temperature data within the same range sourced from National Solar Irradiation Database (NSRDB) were used to train and test the various ANFIS architectures. Different ANFIS models, including different membership functions and sets of input data, were simulated on MATLAB, and the performance of the models was evaluated using standard matrices such as root mean square error (RMSE) and mean absolute percentage error (MAPE). The result of this study showed that the inclusion of temperature as an exogenous variable and the use of Gaussian membership function yielded a higher forecast accuracy with MAPE 0.05754% and RMSE 0.56614. This implies that using temperature as an input variable and Gaussian membership functions can improve forecasting accuracy.

30 June 2026 in International Journal of Engineering and Advanced Technology
Verified
Journal Article
Closed access
OOOsita Uchechukwu Omeje
Osita Uchechukwu Omeje
EAEngr. Olukunle James Amore
Engr. Olukunle James Amore
LILinus Idoko
Linus Idoko
The increase in harmonic distortion in power networks due to non-linear loads is now a major challenge for utilities, and utilities are finding ways to reduce these harmonics by imposing penalties on customers that generate them. This research aimed to design a fairer harmonic penalty model for customers who inject harmonics into power systems, accounting for harmonics injected from both the customer and utility sides. The harmonics injected from the customer and utility sides of the PCC (Point of Common Coupling) were evaluated, and the resulting Total Harmonic Distortions (THD) were used to assess the penalty and compensation due to the customer. The customers electricity bill was also evaluated using this penalty model. The application of this penalty model results in a fairer model in which utility-penalised customers are compensated for harmonics injected from the network that exceed the limits, as well as for harmonics injected from the utility side. This research offers a substantial improvement over existing penalty models, as customers were treated fairly by considering the harmonics generated by their networks and the utility networks.

13 February 2026 in Journal of King Saud University – Engineering Sciences
Verified
Journal Article
Open access
PDF file
OOOsita Uchechukwu Omeje
Osita Uchechukwu Omeje
FOFrank Nwoye Okafor
Frank Nwoye Okafor
ABAdeola Olugbenga Balogun
Adeola Olugbenga Balogun
This paper presents a novel technique for identifying the sources of individual harmonics in an electrical network that contains multiple nonlinear loads. The differential in the harmonic apparent power flowing through a section of the network is used to trace the source of the harmonic. The technique is proposed as an improvement over active and reactive power flows, which have been widely used in literature for identifying harmonic sources. Analytical models are derived to justify the use of apparent power flow as a method for locating harmonic sources. A comparative analysis is performed on the reliability of applying active, reactive, and apparent power flows for each harmonic component in identifying harmonic sources in a network comprising linear and nonlinear load structures. A criterion for assessing the applicability of the developed method is developed. A case study of a transmission network that supplies electricity to an industrial area that mainly consists of steel manufacturing plants is used to validate the developed technique. The developed technique is equally implemented in a hardware laboratory test rig. Results obtained from the analysis show that the flow of apparent power proves to be the most promising in predicting the source of harmonics in a network. Knowledge of the network and source impedances is not required in the application of the method. A choice of metering point or the relative size of the source and consumer impedances does not affect the results obtained with the method, provided that the developed application criterion is met. The developed method can be used to detect harmonic sources when multiple loads are connected to a point of common coupling (PCC).